En-2

Control unit (optional)

Types of remote controllers:

 

Wireless remote controller 
(Be sure to use after connecting receiver unit.)

 

Wired remote controller

 

Simple remote controller

For operation method, please refer to the Operating Manual of each 
device.

MANUAL AUTO OPERATION

Use the MANUAL AUTO operation in the event the remote control unit is 
lost or otherwise unavailable.

*Limited to only when receiver unit is connected.

 CAUTION

Do not press the MANUAL AUTO button with wet hands or pointed ob-
jects, otherwise an electric shock or malfunction may occur.

Starting Operation

Press the MANUAL AUTO button on the operating 
control panel.

The operation can be set in the following setting.

Operating mode

AUTO:
When Auto mode cannot be selected, it will 
operate in the same mode as the other indoor 
unit in the same system. (When other indoor 
unit in the same system doesn’t operate, the air 
conditioner will operate in cooling.)

Fan speed

AUTO

Setting temperature

23 °C

Stopping Operation

Press the MANUAL AUTO button on the operating 
control panel.

OPERATING TIPS

Operation and Performance

About priority state and standby state

 

Multiple indoor units can be connected within the same system. De-
pending on the system, choice of operating mode are limited.

Cooling priority state:

When the other indoor units within the same system operate in cooling 
or dry mode, heating can not be selected at the same time.

Heating priority state:

When the other indoor units within the same system operate in heating 
mode, cooling and dry mode can not be selected at the same time.

Standby state:

The standby state activates when 2 or more indoor units start up at the 
same time in different mode. Any indoor unit other than priority mode 
will wait in standby state until priority mode changes (operation starts 
as soon as priority is switched).
At this time, the OPERATION indicator lamp (green) lights up and the 
TIMER indicator lamp (orange) 

fl

 ashes (limited to only when receiver 

unit is connected).

Low ambient cooling

 

When the outdoor temperature drops, the outdoor unit’s fans may 
switch to Low Speed, or one of the fans may stop intermittently.

Heating performance

 

Heating mode operates on the heat-pump principle, absorbing heat 
from outdoor air and transferring that heat indoors. As a result, the 
operating performance is reduced as outdoor air temperature drops. 
If you feel that insuf

fi

 cient heating performance is being produced, we 

recommend you use this air conditioner in conjunction with another 
type of heating appliance.

 

Heating mode heat your entire room by recirculating air throughout the 
room, with the result that some time may be required after 

fi

 rst starting 

the air conditioner until the room is heated.

Microcomputer-controlled automatic defrosting

 

When using the Heating mode under conditions of low outdoor air 
temperature high humidity, frost may form on the outdoor unit, result-
ing in reduced operating performance. In order to prevent this kind of 
reduced performance, this unit is equipped with a Microcomputer-con-
trolled automatic defrosting function. If frost forms, the air conditioner 
will temporarily stop, and the defrosting circuit will operate brie

fl

 y (for 

about 4 to 15 minutes). 
During Automatic Defrosting operation, the OPERATION indicator 
lamp (green) will 

fl

 ash (limited to only when receiver unit is connected).

Oil recovery operation

 

Periodically, the oil recovery operation is performed in order to return 
compressor oil to the outdoor unit. 
During oil recovery operation, the OPERATION indicator lamp (green) 
will 

fl

 ash (for about 10 minutes) (limited to only when receiver unit is 

connected).

Temperature and humidity range

 

The temperature and humidity required for operating this product is as 
shown in the following table.

Cooling/Dry Mode

Heating Mode

Outdoor 
temperature

Please refer to the speci

fi

 cation of outdoor units.

Indoor 
temperature

About 18 to 32 °C DB

About 10 to 30 °C DB

Indoor humidity

About 80% or less

 

If the air conditioner is operated under higher temperature conditions 
than those listed, the built-in protection circuit may operate to prevent 
internal circuit damage. Also, during Cooling and Dry modes, if the unit 
is used under conditions of lower temperature than those listed above, 
the heat-exchanger may freeze, leading to water leakage and other 
damage.

 

If the unit is used for long periods under high-humidity conditions, 
condensation may form on the surface of the indoor unit, and drip onto 
the 

fl

 oor or other objects underneath.

 

Do not use this unit for any purposes other than the Cooling, Heating, 
Dehumidifying, and air-circulation of rooms in ordinary dwellings.

9374343416_OM_9L.indb   2

9374343416_OM_9L.indb   2

2018/6/6   11:35:37

2018/6/6   11:35:37

Содержание Airstage ARXN009GLBH

Страница 1: ...altyp Bewahren Sie dieses Handbuch für eine spätere Bezugnahme auf MANUALE DI ISTRUZIONI UNITÀ INTERNA tipo a condotto Conservare questo manuale per consultazione futura ΕΓΧΕΙΡΙΔΙΟ ΛΕΙΤΟΥΡΓΙΑΣ ΕΣΩΤΕΡΙΚΗ ΜΟΝΑΔΑ Τύπος αγωγού Διατηρήστε το παρόν εγχειρίδιο για μελλοντική αναφορά РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ ВНУТРЕННИЙ МОДУЛЬ Короб Сохраните данное руководство для последующего использования KULLANIM KI...

Страница 2: ... the air filter Do not pour water or cleaning solvent on the unit directly or wash the unit with them Do not expose the air conditioner directly to water Do not operate the air conditioner with wet hands Check the condition of the installation stand for damage Operate only with air filters installed Do not drink the water drained from the air conditioner Do not apply any heavy pressure to radiator...

Страница 3: ...that heat indoors As a result the operating performance is reduced as outdoor air temperature drops If you feel that insufficient heating performance is being produced we recommend you use this air conditioner in conjunction with another type of heating appliance Heating mode heat your entire room by recirculating air throughout the room with the result that some time may be required after first s...

Страница 4: ...is the standby state See page 2 Noise is heard In the following conditions there are sounds of water flowing from the indoor unit and the operation sound becomes loud These are the sounds of the flowing of refrigerant When operation starts When oil recovery operation finishes When automatic defrosting operation finishes During operation a slight squeaking sound may be heard This is the result of m...

Страница 5: ... INPUT POWER W 88 122 122 CURRENT A 0 53 0 78 0 78 SOUND PRESSURE LEVEL HIGH dB A 32 35 35 MED dB A 30 32 32 LOW dB A 28 29 29 DIMENSIONS WEIGHT HEIGHT mm 198 WIDTH mm 1 100 DEPTH mm 620 WEIGHT kg 26 Acoustic Noise Information The maximum sound pressure level is less than 70 dB A for both indoor unit and outdoor unit According to IEC 704 1 and ISO 3744 Standard static pressure 25 Pa 9374343416_OM_...

Страница 6: ...9374343416_OM_9L indb 6 9374343416_OM_9L indb 6 2018 6 6 11 35 40 2018 6 6 11 35 40 ...

Отзывы: