En-4

SPECIFICATIONS

MODEL

ARXC036GTEH

POWER SOURCE

230 V ~ 50/60 Hz

AVAILABLE VOLT-
AGE RANGE

198 to 264V (50Hz)
198 to 253V (60Hz)

COOLING 
CAPACITY

[kW]

11.2 

[Btu/h]

38,200

HEATING 
CAPACITY

[kW]

12.5 

[Btu/h]

42,700

INPUT 
POWER

[W]

207

CURRENT

[A]

1.25

SOUND PRESSURE LEVEL

HIGH

dB [A]

42

MED

dB [A]

36

LOW

dB [A]

32

DIMENSIONS & WEIGHT

HEIGHT

[mm]

400

WIDTH

[mm]

1,050

DEPTH

[mm]

500

WEIGHT

[kg]

40

 

Acoustic Noise Information : 
The maximum sound pressure level is less than 70 dB (A) for both 
indoor unit and outdoor unit. According to IEC 704-1 and ISO 3744.

 

Standard static pressure : 100 Pa

MODEL

ARXC072GTEH ARXC090GTEH ARXC096GTEH

POWER SOURCE

230 V ~ 50/60 Hz

AVAILABLE VOLT-
AGE RANGE

198 to 264V (50Hz)
198 to 253V (60Hz)

COOLING 
CAPACITY

[kW]

22.4 25.0 28.0 

[Btu/h]

76,400

85,300

95,500

HEATING 
CAPACITY

[kW]

25.0 28.0 31.5 

[Btu/h]

85,300

95,500

107,500

INPUT 
POWER

[W]

681

819

838

CURRENT

[A]

4.10

4.86

4.89

SOUND PRESSURE LEVEL

HIGH

dB [A]

47

48

48

MED

dB [A]

43

46

45

LOW

dB [A]

40

44

42

DIMENSIONS & WEIGHT

HEIGHT

[mm]

450

550

WIDTH

[mm]

1,587

1,587

DEPTH

[mm]

700

700

WEIGHT

 [kg] 

84 

105 

 

Acoustic Noise Information : 
The maximum sound pressure level is less than 70 dB (A) for both 
indoor unit and outdoor unit. According to IEC 704-1 and ISO 3744.

 

Standard static pressure : 150 Pa 

9373384298_OM.indb   4

9373384298_OM.indb   4

2018/12/24   11:49:38

2018/12/24   11:49:38

Содержание AirStage ARXC036GTEH

Страница 1: ...esto manuale per consultazione futura Ελληνικά Português ΕΓΧΕΙΡΙΔΙΟ ΛΕΙΤΟΥΡΓΙΑΣ ΕΣΩΤΕΡΙΚΗ ΜΟΝΑΔΑ Τύπος αγωγού Διατηρήστε το παρόν εγχειρίδιο για μελλοντική αναφορά MANUAL DE FUNCIONAMENTO UNIDADE INTERIOR Tipo de tubagem Guarde este manual para consulta futura Русский Türkçe РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ ВНУТРЕННИЙ МОДУЛЬ Короб Сохраните данное руководство для последующего использования KULLANIM KIL...

Страница 2: ... or wash the unit with them Do not expose the air conditioner directly to water Do not operate the air conditioner with wet hands Check the condition of the installation stand for damage Operate only with air filters installed Do not drink the water drained from the air conditioner Do not apply any heavy pressure to radiator fins Do not use inflammable gases near the air conditioner Do not touch t...

Страница 3: ...d operating performance In order to prevent this kind of reduced performance this unit is equipped with a Microcomputer con trolled automatic defrosting function If frost forms the air conditioner will temporarily stop and the defrosting circuit will operate briefly for about 4 to 15 minutes During Automatic Defrosting operation the OPERATION indicator lamp green will flash limited to only when re...

Страница 4: ...ard occasionally This sound is produced by the Automatic Defrosting operation See page 2 Smells Some smell may be emitted from the indoor unit This smell is the result of room smells furniture tobacco etc which have been taken into the air conditioner Fog comes out of the indoor unit During Cooling operation a thin mist may be seen emitted from the indoor unit This results from the sudden Cooling ...

Страница 5: ...100 Pa MODEL ARXC072GTEH ARXC090GTEH ARXC096GTEH POWER SOURCE 230 V 50 60 Hz AVAILABLE VOLT AGE RANGE 198 to 264V 50Hz 198 to 253V 60Hz COOLING CAPACITY kW 22 4 25 0 28 0 Btu h 76 400 85 300 95 500 HEATING CAPACITY kW 25 0 28 0 31 5 Btu h 85 300 95 500 107 500 INPUT POWER W 681 819 838 CURRENT A 4 10 4 86 4 89 SOUND PRESSURE LEVEL HIGH dB A 47 48 48 MED dB A 43 46 45 LOW dB A 40 44 42 DIMENSIONS W...

Страница 6: ...9373384298_OM indb 6 9373384298_OM indb 6 2018 12 24 11 49 40 2018 12 24 11 49 40 ...

Отзывы: