En-2

MANUAL AUTO OPERATION

Use the MANUAL AUTO operation in the event the remote controller is 
lost or otherwise unavailable.
*Limited to only when receiver unit is connected.

 CAUTION

Do not press the MANUAL AUTO button with wet hands or pointed ob-
jects, otherwise an electric shock or malfunction may occur.

Starting Operation

Press the MANUAL AUTO button on the operating 
control panel.

The operation can be set in the following setting.

Operating mode

AUTO:
When Auto mode cannot be selected, it will 
operate in the same mode as the other indoor 
unit in the same system. (When other indoor 
unit in the same system doesn’t operate, the air 
conditioner will operate in cooling.)

Fan speed

AUTO

Setting temperature

74°F (23 °C)

Stopping Operation

Press the MANUAL AUTO button on the operating 
control panel.

Emergency Heat

*  It is available when this function is enabled. Please consult an autho-

rized service personnel as to whether this function is eff ective.

Set emergency heat

During heating operation, press the MANUAL AUTO 
button on the operating control panel.

Auxiliary heater will be primary heater, and the outdoor unit will stop.
The OPERATION Indicator Lamp (Green) blinks during emergency heat-
ing operation.(3 seconds on, 1 second off .)

Cancel emergency heat

During emergency heating operation, press the MAN-
UAL AUTO button on the operating control panel.

OPERATING TIPS

Operation and Performance

About priority state and standby state

 

● Multiple indoor units can be connected within the same system. De-

pending on the system, choice of operating mode are limited.

Cooling priority 
state

When the other indoor units within the same system 
operate in cooling or dry mode, heating cannot be 
selected at the same time.

Heating priority 
state

When the other indoor units within the same system 
operate in heating mode, cooling and dry mode can 
not be selected at the same time.

Standby state

The standby state activates when 2 or more indoor 
units start up at the same time in diff erent mode. 
Any indoor unit other than priority mode will wait in 
standby state until priority mode changes (operation 
starts as soon as priority is switched).
At this time, the OPERATION indicator lamp (green) 
lights up and the TIMER indicator lamp (orange) 
fl ashes. (limited to only when receiver unit is con-
nected)

Low ambient cooling

 

● When the outdoor temperature drops, the outdoor unit’s fans may 

switch to Low Speed, or one of the fans may stop intermittently.

Heating performance

 

● Heating mode operates on the heat-pump principle, absorbing heat 

from outdoor air and transferring that heat indoors. As a result, the 
operating performance is reduced as outdoor air temperature drops. 
If you feel that insuffi  cient heating performance is being produced, we 
recommend you use this air conditioner in conjunction with another 
type of heating appliance.

 

● Heating mode heat your entire room by recirculating air throughout the 

room, with the result that some time may be required after fi rst starting 
the air conditioner until the room is heated.

Microcomputer-controlled automatic defrosting

 

● When using the Heating mode under conditions of low outdoor air 

temperature high humidity, frost may form on the outdoor unit, result-
ing in reduced operating performance. In order to prevent this kind of 
reduced performance, this unit is equipped with a Microcomputer-con-
trolled automatic defrosting function. If frost forms, the air conditioner 
will temporarily stop, and the defrosting circuit will operate briefl y (for 
about 4 to 15 minutes). 
During Automatic Defrosting operation, the OPERATION indicator lamp 
(green) will fl ash (limited to only when receiver unit is connected).

Oil recovery operation

 

● Periodically, the oil recovery operation is performed in order to return 

compressor oil to the outdoor unit. 
During oil recovery operation, the OPERATION indicator lamp (green) 
will fl ash (for about 10 minutes) (limited to only when receiver unit is 
connected).

9374343454-01_OM.indb   2

9374343454-01_OM.indb   2

2019/8/30   10:15:31

2019/8/30   10:15:31

Содержание Airstage ARUM24TLAV2

Страница 1: ...reference Français Español MODE D EMPLOI MANUAL DE FUNCIONAMIENTO UNITÉ INTÉRIEURE type conduit UNIDAD INTERIOR Tipo conducto Conservez ce manuel pour pour toute référence ultérieure Conserve este manual para posibles consultas futuras 9374343454 01_OM indb cover1 9374343454 01_OM indb cover1 2019 8 30 10 15 30 2019 8 30 10 15 30 ...

Страница 2: ...e unit with them Do not expose the air conditioner directly to water Do not operate the air conditioner with wet hands Check the condition of the installation stand for damage Operate only with air filters installed Do not drink the water drained from the air conditioner Do not apply any heavy pressure to radiator fins Do not use flammable gases near the air conditioner Do not touch the piping during...

Страница 3: ...y state activates when 2 or more indoor units start up at the same time in different mode Any indoor unit other than priority mode will wait in standby state until priority mode changes operation starts as soon as priority is switched At this time the OPERATION indicator lamp green lights up and the TIMER indicator lamp orange flashes limited to only when receiver unit is con nected Low ambient cool...

Страница 4: ... stop If you wish to warm the room further set the thermostat for a higher setting During oil recovery operation the airflow may stop for approximately 10 minutes See page 2 During Heating operation the unit will temporarily stop operation be tween 4 and 15 minutes as the Automatic Defrosting mode operates See page 2 The fan may operate at low speed during Dry operation or when the unit is monitori...

Страница 5: ...m cannot be solved even when the troubleshooting checks have been performed The FILTER indicator lamp red is flashing very fast when receiver unit is connected The wired remote controller or simple remote controller indicate Er when connected It has burning smell For details on marking the Flashing lamps please refer to the Manual of IR Receiver Unit or Wired Remote Controller SPECIFICATIONS MODEL ...

Страница 6: ...9374343454 01_OM indb 5 9374343454 01_OM indb 5 2019 8 30 10 15 31 2019 8 30 10 15 31 ...

Отзывы: