FEATURES AND FUNCTIONS

FEATURES AND FUNCTIONS

 Energy saving and Comfortable function

INVERTER

At the start of operation, large amount of power is used to 
bring the room quickly to the desired temperature. Afterwards, 
the unit automatically switches to a low power setting for eco-
nomic and comfortable operation.

ECONOMY OPERATION

When ECONOMY operation mode is operated, the room tem-
perature will be little higher than the set-temp under cooling 
mode and lower than set-temp under heating mode. Therefore, 
the ECONOMY mode is able to save more energy than other 
normal mode.

SWING OPERATION

The Airflow Direction Louvers swings automatically up and 
down so that the air speeds to every nook and corner of your 
room.

SUPER QUIET OPERATION

When the FAN button is used to select QUIET, the indoor unit 
begins super quiet operation; the indoor unit’s airflow is re-
duced to produce quieter operation.

AUTO CHANGEOVER

The operation mode (cooling, dry, heating) is switched auto-
matically to maintain the set temperature, and the temperature 
is kept constant at all times.

10°C HEAT OPERATION

The room temperature can be maintained at 10°C so as to 

prevent the room temperature from falling too far.

 Convenient function

PROGRAM TIMER

The program timer allows you to integrate OFF timer and ON timer 

operations in a single sequence. The sequence can involve 1 tran-

sition from OFF timer to ON timer, or from ON timer to OFF timer, 

within a 24 hour period.

SLEEP TIMER

When the SLEEP timer button is pressed during heating mode, 

the air conditioner’s thermostat setting is gradually lowered dur-

ing the period of operation; during cooling or dry mode, the ther-

mostat setting is gradually raised during the period of operation. 

When the set time is reached, the unit automatically turns off.

 Clean function

REMOVABLE INTAKE GRILLE

The indoor unit’s intake grille can be removed for easy clean-

ing and maintenance.

MILDEW-RESISTANT FILTER

The AIR FILTER has been treated to resist mildew growth, 

thus allowing cleaner use and easier care.

POLYPHENOL CATECHIN AIR CLEANING FILTER

The polyphenol catechin air cleaning 

fi

 lter uses static electric-

ity to clean 

fi

 ne particles and dust in the air such as tobacco 

smoke and plant pollen that are too small to see. The filter 

contains catechin, which is highly effective against various 

bacteria by suppressing the growth of the bacteria adsorbed to 

the 

fi

 lter. Note that when the air cleaning 

fi

 lter is installed, the 

amount of air produced decreases, causing a slight decrease 

in the indoor unit’s performance.

NEGATIVE AIR IONS DEODORIZING FILTER

It comprises pottery super micro particles which can produce 
negative air ions having the effect of deodorizing and can ab-
sorb and remit the peculiar smell at home.

 Remote controller

WIRELESS REMOTE CONTROLLER

The wireless remote controller allows convenient control of air 

conditioner operation.

WIRED REMOTE CONTROLLER (OPTION)

The optional wired remote controller can be used. When you 

use remote controller, there are following different points as 

compared with using wireless remote controller.
[The additional functions for wired ones]

• Weekly timer

• Temperature set back timer
And you can use both wired and wireless remote controller si-

multaneously. (But function is limited)

When the restricted functions on the remote controller are 

used, beeping sound will be heard, OPERATION, TIMER and 

the 3rd lamp of the indoor unit will 

fl

 ash.

[The restricted functions for wireless ones]

• 10°C HEAT OPERATION

• PROGRAM TIMER

• SLEEP TIMER

En-2

9332280029-04_OM.indb   Sec1:2

9332280029-04_OM.indb   Sec1:2

2/25/2013   3:27:48 PM

2/25/2013   3:27:48 PM

Содержание Air Conditioner Compact Wall Mounted Type

Страница 1: ...9332280029 04 Compact Wall Mounted Type MANUAL DE INSTRUÇÕES GUARDE ESTE MMANUAL DE FUNCIONANENTO PARA REFERÊNCIA FUTURA 9332280029 04_OM indb 1 9332280029 04_OM indb 1 2 25 2013 3 27 48 PM 2 25 2013 3 27 48 PM ...

Страница 2: ...nd specified cord are required In the event of a malfunction burning smell etc immediately stop operation turn off the breaker and consult author ized service personnel In the event of refrigerant leakage be sure to keep away from fire or any flammables consult an authorized service per sonnel Provide occasional ventilation during use Do not direct airflow at fireplaces or heating apparatus Do not...

Страница 3: ...f operation When the set time is reached the unit automatically turns off Clean function REMOVABLE INTAKE GRILLE The indoor unit s intake grille can be removed for easy clean ing and maintenance MILDEW RESISTANT FILTER The AIR FILTER has been treated to resist mildew growth thus allowing cleaner use and easier care POLYPHENOL CATECHIN AIR CLEANING FILTER The polyphenol catechin air cleaning filter...

Страница 4: ...has been drawn to show all possible indicators in actual operation however the display will only show those indicators appropriate to the current operation Fig 6 Fig 2 Fig 3 Fig 4 En 3 9332280029 04_OM indb Sec1 3 9332280029 04_OM indb Sec1 3 2 25 2013 3 27 48 PM 2 25 2013 3 27 48 PM ...

Страница 5: ...ver behind Airflow Direction Louver C Drain Hose Fig 5 Remote Controller D Signal Transmitter E MODE button F 10 C HEAT button G ECONOMY button H SLEEP button I TIMER MODE button J FAN button K START STOP button L SET button Vertical M SWING button N SET TEMP button O TIMER SET button P CLOCK ADJUST button Q TEST RUN button This button is used when installing the air conditioner and should not be ...

Страница 6: ... 2 Insert batteries Be sure to align the battery polarities correctly 3 Close the battery compartment lid Set the Current time 1 Press the CLOCK ADJUST button Fig 5 P Use the tip of a ball point pen or other small object to press the button 2 Use the TIMER SET buttons Fig 5 O to adjust the clock to the current time button Press to advance the time button Press to reverse the time Each time the but...

Страница 7: ...ressed the fan speed changes in the following order AUTO HIGH MED LOW QUIET About 3 seconds later the entire display will reappear When set to AUTO Heating Fan operates so as to optimally circulate warmed air However the fan will operate at very low speed when the temperature of the air issued from the indoor unit is low Cooling As the room temperature approaches that of the thermostat setting the...

Страница 8: ...ovided to allow the indoor unit to warm up before begin full operation When the outdoor temperature is very low frost may form on the outdoor unit and its performance may be reduced In order to remove such frost the air conditioner will automatically enter the defrost cycle from time to time During Automatic Defrosting operation the OPERATION Indicator Lamp Fig 3 5 will flash and the heat operatio...

Страница 9: ...am timer The program timer allows you to integrate OFF timer and ON timer operations in a single sequence The sequence can involve 1 transition from OFF timer to ON timer or from ON timer to OFF timer within a 24 hour period The first timer function to operate will be the 1 set nearest to the current time The order of operation is indicated by the arrow in the Remote Controller s Display OFF ON or...

Страница 10: ...bout the SLEEP Timer To prevent excessive warming or cooling during sleep the SLEEP timer function automatically modifies the thermostat setting in accordance with the set time setting When the set time has elapsed the air conditioner completely stops During Cooling Dry operation When the SLEEP timer is set the thermostat setting is automatically raised 1 C every 1 hour When the thermostat setting...

Страница 11: ...low Direction Louvers Whenever making horizontal airflow adjustments start air conditioner operation and be sure that the vertical air direction louvers are stopped DANGER Never place fingers or foreign objects in side the outlet ports since the internal fan operates at high speed and personal injury could be caused Always use the Remote Controller s SET button to adjust the vertical airflow lou v...

Страница 12: ...cooled or heated well during ECONOMY operation select normal operation During the monitor period in the AUTO mode the air conditioner operation will not change to ECONOMY operation even if ECONOMY operation is selected by pressing the ECONOMY operation button OPERATION Indicator Lamp Lighting OFF TIMER ECONOMY SWING OPERATION Begin air conditioner operation before performing this procedure To sele...

Страница 13: ...ollowing operation can be used SET OPERATION Indicator Lamp Lighting OFF TIMER ECONOMY CLEANING AND CARE Before cleaning the indoor unit be sure to turn it off and disconnect the Power Supply Cord Be sure the Intake Grille Fig 1 8 is installed securely When removing or replacing the air filters be sure not to touch the heat exchanger as personal injury may result CAUTION To avoid excessive wear of...

Страница 14: ...er washing allow to dry thoroughly in a shaded place 3 Replace the Air Filter and close the In take Grille 1 Align the sides of the air filter with the panel and push in fully making sure the 2 lower tabs are returned prop erly to their holes in the panel 2 Close the Intake Grille For purposes of example the illustration shows the indoor unit without Intake Grille installed Dust can be cleaned fro...

Страница 15: ... 3 years so as to maintain the deodorizing effect Filter frame is not a one off product Please buy dedicated deodorizing filter UTR FA16 2 Sold separately when exchanging the filter Maintenance of Deodorizing Filters In order to maintain the deodorizing effect please clean the filter in the follow way once 3 months 1 Remove the deodorizing filter 2 Clean with water and dry in the air 1 Flush the f...

Страница 16: ...n for at least five seconds to display the current signal code initially set to 3 Press the buttons to change the signal code between Match the code on the display to the air conditioner signal code 4 Press the MODE button again to return to the clock display The signal code will be changed If no buttons are pressed within 30 seconds after the signal code is displayed the system returns to the ori...

Страница 17: ...s temporarily very low to allow internal parts to warm up During Heating operation if the room temperature rises above the thermostat setting the outdoor unit will stop and the indoor unit will operate at very low fan speed If you wish to warm the room further set the thermostat for a higher setting During Heating operation the indoor unit will temporarily stop opera tion between 7 and 15 minutes ...

Страница 18: ...ance This air conditioner operates on the heat pump principle absorbing heat from outdoor air and transferring that heat to indoor unit As a result the operating performance is reduced as outdoor air temperature drops If you feel that insufficient heating performance is being produced we recommend you use this air conditioner in conjunction with another kind of heating appliance Heat pump air cond...

Страница 19: ...xiliary space heaters as required Seasonal and outdoor temperature conditions the struc ture of the rooms and the number of persons present may also result in differences of operating efficiency We rec ommend that you try various operating patterns in order to confirm the level of heating and cooling output provided by your units and use the units in the way that best matches your family s lifesty...

Страница 20: ...9332280029 04_OM indb Sec1 19 9332280029 04_OM indb Sec1 19 2 25 2013 3 27 55 PM 2 25 2013 3 27 55 PM ...

Отзывы: