OPERATING TIPS

During heating mode:

Set the thermostat to a temperature setting 
that is higher than the current room tem-
perature. The heating mode will not oper-
ate if the thermostat is set lower than the 
actual room temperature.

During cooling/dry mode:

Set the thermostat to a temperature set-
ting that is lower than the current room 
temperature. The cooling and dry modes 
will not operate if the thermostat is set 
higher than the actual room temperature 
(in cooling mode, the fan alone will ope-
rate).

During fan mode:

You can not use the unit to heat and cool 
your room.

 

HEAT *:

 

  Use to warm your room.

   

  When heating mode is selected, the air conditioner will operate at very 

low fan speed for about 3 to 5 minutes, after which it will switch to the 

selected fan setting. This period of time is provided to allow the indoor 

unit to warm up before beginning full operation.

   

  When the room temperature is very low, frost may form on the outside 

unit, and its performance may be reduced. In order to remove such frost, 

the unit will automatically enter the defrost cycle from time to time. During 

automatic defrosting operation, the heat operation will be interrupted.

   

  After the start of heating operation, it takes sometime before the room 

gets warmer.

 COOL:

 

  Use to cool your room.

 DRY:

 

  Use for gently cooling while dehumidifying your room.

   

  You cannot heat the room during dry mode.

   

  During dry mode, the unit will operate at low speed; in order to adjust 

room humidity, the indoor unit’s fan may stop from time to time. Also, the 

fan may operate at very low speed when adjusting room humidity.

   

  The fan speed cannot be changed manually when dry mode has been 

selected.

 FAN:

 

  Use to circulate the air throughout your room.

Mode Operation

Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).

  When AUTO (automatic changeover) is selected, the air conditioner selects the appropriate operation mode (cooling or 

heating) according to your room’s present temperature.

  When AUTO (automatic changeover) operation 

fi

 rst selected, the fan will operate at low speed for about a few minute, 

during which time the indoor unit detects the room conditions and selects the proper operation mode.

  Room temperature is higher than the de

fi

 ned temperature in temperature 

setting 

 Cooling mode or dry mode

  Room temperature is close to the de

fi

 ned temperature in temperature setting 

 Determined by outdoor temperature

  Room temperature is lower than the de

fi

 ned temperature in temperature 

setting 

 Heating mode 

  When the air conditioner has adjusted your room’s temperature to near the thermostat setting, it will begin monitor opera-

tion. In the monitor operation mode, the fan will operate at low speed. If the room temperature subsequently changes, 
the air conditioner will once again select the appropriate operation (heating, cooling) to adjust the temperature to the 
value set in the thermostat.

  If the mode automatically selected by the unit is not what you wish, select one of the mode operation (HEAT, COOL, DRY, FAN).

  When AUTO (automatic changeover) operation 

fi

 rst selected, the fan will operate at very low speed for about a few 

minutes, during which time the indoor unit detects the room conditions and selects the proper mode.

  Room temperature is higher than the de

fi

 ned temperature in temperature 

setting 

 Cooling mode or dry mode

  Room temperature is close to or lower than the de

fi

 ned temperature in 

temperature setting 

 Monitor operation

  When the indoor unit has adjusted your room’s temperature to near the temperature setting, it will begin monitor opera-

tion. In the monitor operation mode, the fan will operate at low speed. If the room temperature subsequently changes, 
the indoor unit will once again select the appropriate operation (cooling) to adjust the temperature to the value set in the 
temperature setting.

  If the mode automatically selected by the unit is not what you wish, select one of the mode operation (COOL, DRY, FAN).

Cooling or Dry

Heating

Determined by 
outdoor temperature 

De

fi

 ned 

temperature in 
temperature 
setting 

  AUTO [in HEAT & COOL (Reverse Cycle) model]: 

  AUTO (in COOLING model):

De

fi

 ned 

temperature in 
temperature 
setting

Cooling mode 
or Dry mode

Monitor operation 

9374379415-02_OM.indb   Sec1:16

9374379415-02_OM.indb   Sec1:16

2012-4-3   14:04:15

2012-4-3   14:04:15

Содержание ACG12UiA-LL

Страница 1: ...語 Русский KEEP THIS MANUAL FOR FUTURE REFERENCE BEWAHREN SIE DIESES HANDBUCH ZUM SPÄTEREN NACHSCHLAGEN AUF CONSERVEZ CE MANUEL POUR RÉFÉRENCE ULTÉRIEURE CONSERVE ESTE MANUAL PARA SU FUTURA CONSULTA CONSERVARE IL PRESENTE MANUALE PER FUTURE CONSULTAZIONI ΦΥΛΑΞΤΕ ΤΟ ΕΓΧΕΙΡΙΔΙΟ ΓΙΑ ΜΕΛΛΟΝΤΙΚΗ ΑΝΑΦΟΡΑ GUARDE ESTE MANUAL PARA REFERÊNCIA FUTURA РУКОВОДСТВО ДЛЯ СПРАВОК В БУДУЩЕМ BU KILAVUZU DAHA SONRA BA...

Страница 2: ...he power switch on at least 12 hours before starting the unit Do not drink the water drained from the air conditioner Do not use in applications involving the storage of foods plants or animals precision equipment or art works Do not apply any heavy pressure to radiator fins Operate only with air filters installed Do not block or cover the intake grille and outlet port Ensure that any electronic e...

Страница 3: ...nt control of indoor unit operation WIRELESS REMOTE CONTROLLER OPTION The optional wireless remote controller can be used When you use remote controller there are following different points as compared with using wired remote controller The additional function for wireless ones SLEEP timer TIMER 10 C HEAT operation And you can use both wireless and wired remote controller si multaneously But funct...

Страница 4: ...Operation lamp F Timer and Clock indicator G Operation mode indicator H Fan speed indicator I Operation lock indicator J Temperature indicator K Function indicator Defrost indicator Thermo sensor indicator ECONOMY indicator Vertical swing indicator 3 Filter indicator 1 1 3 These functions cannot be used Please also see the operating manual of the option when using it with options etc 1 Can be used...

Страница 5: ... to set the current time Press repeatedly to adjust the current time in 1 minute incre ments Press and hold to adjust the current time in 10 minute increments ex Monday PM11 00 Press again to end SU MO TU WE TH FR SA 1 3 5 Press the SET BACK button to switch between the 12 and 24 hour time displays 3 4 SU MO TU WE TH FR SA SU MO TU WE TH FR SA SET BACK Set the current day and time 9374379415 02_OM...

Страница 6: ... to set the room temperature Press the FAN button to set the fan speed Press the ECONOMY button to start or stop ECONOMY operation For details on the function refer to page 11 To start stop operation To set the operation mode Operation mode setting Room temperature setting Fan speed setting ECONOMY operation AUTO COOL DRY FAN HEAT AUTO HIGH MED LOW QUIET Instructions relating to heating are applic...

Страница 7: ...ss the DAY DAY OFF button and TIMER SET button simul taneously for 2 seconds or more to activate the child lock func tion and lock all of the buttons on the remote controller except the START STOP button SET TEMP buttons MODE button and FAN button Press the buttons again for 2 seconds or more to deactivate the child lock function When the child lock function is activated the mark ap pears If any b...

Страница 8: ...vance ON timer See page 8 Use this timer function to start air conditioner operation The timer operates and air conditioner operation starts after the set time has passed The timer can be set up to 24 hours in advance WEEKLY timer See page 9 Use this timer function to set operating times for each day of the week Use the DAY OFF setting to switch off timed operation for a selected day in the coming...

Страница 9: ...at steps 3 and 4 To complete the weekly timer settings press the TIMER SET button for 2 seconds or more To delete the operating time If the TIMER DELETE button is pressed dur ing steps 3 or 4 the operating time for the selected day will be deleted If all the days are selected the operating times for all of the days will be deleted NOTES The operating time can be set in 30 minute increments only Th...

Страница 10: ...ures as those for setup ex The DAY OFF is set for Monday NOTES The DAY OFF setting is only available for days for which weekly settings already exist If the operating time carries over to the next day during a next day setting the effective DAY OFF range will be set as shown below Normal Next day setting The DAY OFF setting can only be set 1 time The DAY OFF setting is cancelled automatically afte...

Страница 11: ...ss the SET TEMP buttons to set the temperature The temperature setting range is the same as the range for the operation mode ex Operating time 15 00 22 00 5 Repeat steps 3 and 4 Press the TIMER SET button for 2 seconds or more to complete the temperature SET BACK timer settings To start SET BACK Press the SET BACK button The SET BACK confirmation display appears for 5 seconds and then the timer st...

Страница 12: ...iency and increasing noise CAUTION ECONOMY OPERATION Begin air conditioner operation before performing this procedure To Use the ECONOMY Operation Press the ECONOMY button The ECONOMY indicator will light ECONOMY operation begins To Stop the ECONOMY Operation Press the ECONOMY button again The ECONOMY indicator will go out Normal operation begins About ECONOMY Operation At the maximum output ECONO...

Страница 13: ...g from the unit This is due to the automatic defrosting operation 15 Airflow is weak or stops When heating operation is started fan speed is temporarily very low to allow internal parts to warm up During heating operation if the room temperature rises above the thermostat setting the outdoor unit will stop and the indoor unit will operate at very low fan speed If you wish to warm the room further ...

Страница 14: ...ttings thermostat cor rectly Is there a window or door open In the case of cooling operation is a window allowing bright sun light to enter Close the curtains In the case of cooling operation are there heating apparatus and computers inside the room or are there too many people in the room Is the unit set for QUIET operation If the problem persists after performing these checks or if you notice bu...

Страница 15: ...m by recircu lating air throughout the room with the result that some time may be required after first starting the air conditioner until the room is heated When Indoor and Outdoor Temperature are High When both indoor and outdoor temperatures are high during use of the heating mode the outdoor unit s fan may stop at times Microcomputer controlled Automatic Defrosting When using the heating mode u...

Страница 16: ...e fan will operate at low speed for about a few minute during which time the indoor unit detects the room conditions and selects the proper operation mode Room temperature is higher than the defined temperature in temperature setting Cooling mode or dry mode Room temperature is close to the defined temperature in temperature setting Determined by outdoor temperature Room temperature is lower than ...

Страница 17: ...ry various operating patterns in order to confirm the level of heating and cooling output provided by your units and use the units in the way that best matches your family s lifestyle lf you discover that 1 or more units delivers a low level of cooling or heating during simultaneous operation we recommend that you stop simultaneous operation of the multiple units Operation cannot be done in the fo...

Страница 18: ...splayed inspection of the air conditioning system is necessary Please consult authorized service personnel Unit number usually 00 Error code ex Self diagnosis check 9374379415 02_OM indb Sec1 18 9374379415 02_OM indb Sec1 18 2012 4 3 14 04 16 2012 4 3 14 04 16 ...

Отзывы: