FUNCTION SETTING

Follow the instructions in the Local Setup Procedure, which is supplied
with the remote control, in accordance with the installed condition. After
the power is turned on, perform the Function Setting on the remote
control.

The settings may be selected between the following two: Function
Number or Setting Value.

Settings will not be changed if invalid numbers or setting values are
selected.

Setting the Ceiling Height

Select the setting values in the table below according to the height of
the ceiling. (The unit is factory-set to “00”.)

Jumper wire

JM2

Connect

Connect

Disconnect

Disconnect

Remote control unit

signal code

A (Primary setting)

b

c

d

JM1

Connect

Disconnect

Connect

Disconnect

Setting the Filter Sign

The indoor unit has a sign to inform the user that it is time to clean the
filter.

Select the time setting for the filter sign display interval in the table
below according to the amount of dust or debris in the room. (The unit
is factory-set to “00”.)

If you do not wish the filter sign to be displayed, select the setting value
for “No indication”.

Setting the Cooler Room Temperature Correction

Depending on the installed environment, the room temperature sensor
may require a correction. The settings may be selected as shown in the
table below. (The unit is factory-set to “00”.)

Setting Value

00

01

Setting Description

Standard

Lower control

Function Number

30

Setting the Heater Room Temperature Correction

Depending on the installed environment, the room temperature sensor
may require a correction. The settings may be changed as shown in the
table below. (The unit is factory-set to “00”.)

Setting Value

00

01

02

03

Setting Description

Standard

Lower control

Slightly warmer control

Warmer control

Function Number

31

Setting Other Functions

The following settings are also possible, depending on the operating
conditions. (The unit is factory-set to “00”.)

Auto Restart

Setting Value

00

01

Setting Description

Yes

No

Function Number

40

Indoor Room Temperature Sensor Switching Function (Wired remote con-
troller only)

Setting Value

00

01

Setting Description

No

Yes

Function Number

42

If setting value is “00”, room temperature is controlled by the indoor unit
temperature sensor.

If setting value is “01”, room temperature is controlled by either indoor
unit temperature sensor or remote control unit sensor.

[When using the wireless remote controller]

SWITCHING REMOTE CONTROL UNIT SIGNAL
CODES

Confirm the setting of the remote control unit signal code and the printed
circuit board setting.
If these are not confirmed, the remote control unit cannot be used to
operate for the air conditioner.

TEST RUN

CHECK ITEMS

(1) Is operation of each button on the remote control unit normal?
(2) Does each lamp light normally?
(3) Do not air flow direction louvers operate normally?
(4) Is the drain normal?
(5) Is there any abnormal noise and vibration during operation?

• Do not operate the air conditioner in the running state for a long time.

• Test running

When the air conditioner is run by pressing the remote control unit test
run button, the OPERATION and TIMER lamps flash slowly at the same
time.

[Using the wireless remote control]

• For the operation method, refer to the operating manual.
• The outdoor unit may not operate depending on the room temperature.

In this case, press the test run button on the remote control unit while
the air conditioner is running. (Point the transmitter section of the re-
mote control unit toward the air conditioner and press the test run but-
ton with the tip of a ball-point pen, etc.)

Transmitter section

Test run button

• To end test operation, press the remote control unit START/STOP button.

(When the air conditioner is run by pressing the test run button, the
OPERATION indicator lamp and TIMER indicator lamp will simultane-
ously flash slowly.)

[Using the wired remote control]

• For the operation method, refer to the operating manual.

(1) Stop the air conditioner operation.
(2) Press the master control button and the fan control button simultane-

ously for 2 seconds or more to start the test run.

(3) Press the start/stop button to stop the test run.

Test run display

Setting

Ceiling height

Filter sign

Cooler room temperature
correction
Heater room temperature
correction

Auto restart

Indoor room temperature
sensor switching function

Setting Value

Setting record

Record any changes to the settings in the following table.

[Troubleshooting at the remote control LCD]

This is possible only on the wired remote control.

[SELF-DIAGNOSIS]

If an error occurs, the following display will be shown.
(“EE” will appear in the set room temperature display.)

Unit number

Error code

Ex. Self-diagnosis

0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

1

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

2

OFF

OFF

ON

ON

OFF

OFF

ON

ON

OFF

OFF

ON

ON

OFF

OFF

ON

ON

3

OFF

OFF

OFF

OFF

ON

ON

ON

ON

OFF

OFF

OFF

OFF

ON

ON

ON

ON

4

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

ON

ON

ON

ON

ON

ON

ON

ON

Unit number

DIP SWITCH No.

8

SPECIAL INSTALLATION

METHODS

9

CUSTOMER GUIDANCE

Explain the following to the customer in accordance with the operating
manual:

(1) Starting and stopping method, operation switching, temperature ad-

justment, timer, air flow switching, and other remote control unit op-
erations.

(2) Air filter removal and cleaning, and how to use the air louvers.
(3) Give the operating and installation manuals to the customer.
(4) If the signal code is changed, explain to the customer how it changed

(the system returns to signal code A when the batteries in the remote
control unit are replaced).

*(4) is applicable to using wireless remote control.

Indoor unit

: 0.5s ON/0.5s OFF (Flash)

: OFF

Troubleshooting

(Troubleshooting with the indoor display)
Troubleshooting at the display is possible either on the wired or wireless
remote control.

The OPERATION, TIMER and FILTER lamp operate as follows table ac-
cording to the error contents.

SU MO TU WE TH FR SA

3

4

ON

1

2

If “CO” appears in the unit number display, there is a remote controller
error. Refer to the installation instruction sheet included with the remote
controller.

Example : No. 3

 CAUTION

1

When setting DIP switches, do not touch any other parts
on the circuit board directly with your bare hands.

2

Be sure to turn off the main power.

1. GROUP CONTROL SYSTEM

A number of indoor units can be operated at the same time using a
single remote controller.
(1) Wiring method (indoor unit to remote controller)

1  2  3

1  2  3

1  2  3

1  2  3

1  2  3

(2) DIP switch setting (indoor unit)

Set the unit number of each indoor unit using DIP switch on the indoor
unit circuit board. (See following table and figure.)
DIP switch is normally set to make unit number No. 0.

Indoor unit

No. 0

Indoor unit

No. 1

Indoor unit

No. 2

Indoor unit

No. 3

Remote
controller

Remote controller wire

After completing the FUNCTION SETTING, be sure to turn off the power
and turn it on again.

PART NO. 9378042018

7

FRESH-AIR INTAKE

(1) Open up the knockout hole for the fresh-air intake, as shown in the

figure. (If using half-concealed installation, open up the top knockout
hole instead.)

For half concealed
installation

Indoor unit

 CAUTION

1

When removing the cabinet (iron plate), be careful not
to damage the indoor unit internal parts and surroun-
ding area (outer case).

2

When processing the cabinet (iron plate), be careful
not to injure yourself with burrs, etc.

(2) Fasten the round flange (optional) to the fresh-air intake, as shown in

the figure. (If using half-concealed installation, attach to the top.)

[After completing “

2

 INDOOR UNIT INSTALLATION”...]

(3) Connect the duct to the round flange.

(4) Seal with a band and vinyl tape, etc. so that air does not leak from the

connection.

Round duct (option parts)

FILTER lamp (Orange)

TIMER lamp (Green)

OPERATION lamp (Red)

Duct

Setting Value

00

01

Setting Description

Standard

(2.3 m to 3.0 m)

High ceiling

(3.0 m or more)

Function Number

20

Setting Value

00

01

02

03

Setting Description

Standard

(2,500 hours)

Long interval

(4,400 hours)

Short interval

(1,250 hours)

No indication

Function Number

11

Indoor unit

Printed circuit board

Error code

Error contents

Indoor signal error

Wired remote controller abnormal

Indoor room temperature sensor error

Indoor heat exchanger temperature sensor (middle)
error

Indoor heat exchanger temperature sensor (inlet)
error

Float switch operated

Outdoor discharge pipe temperature sensor error

Outdoor heat exchanger temperature sensor (outlet)
error

Outdoor temperature sensor error

Heatsink thermistor error

Compressor temperature sensor error

2-way valve temperature sensor error

3-way valve temperature sensor error

Outdoor heat exchanger temperature sensor (middle)
error

Indoor manual auto switch abnormal

Power supply frequency detection error

IPM protection

CT error

Compressor location error

Outdoor fan error

Connected indoor unit abnormal

Outdoor unit computer communication error

Indoor fan abnormal

Discharge temperature error

Excessive high pressure protection on cooling

4-way valve abnormal

Pressure switch abnormal

Compressor temperature error

Active filter abnormal

PFC circuit error

01

13

26

27

00

02

04

28

09

0C

06

0A

0E

15

1d

1E

29

20

2A

17

18

1A

1b

1F

1c

12

0F

24

2c

16

2b

19

25

Indoor signal error

Wired remote controller abnormal

Indoor room temperature sensor error

Indoor heat exchanger temperature
sensor (middle) error

Indoor heat exchanger temperature
sensor (inlet) error

Float switch operated

Outdoor discharge pipe temperature
sensor error

Outdoor heat exchanger temperature
sensor (outlet) error

Outdoor temperature sensor error

Heatsink thermistor error

Compressor temperature sensor error

2-way valve temperature sensor error

3-way valve temperature sensor error

Outdoor heat exchanger temperature
sensor (middle) error

Indoor manual auto switch abnormal

Power supply frequency detection
error

IPM protection

CT error

Compressor location error

Outdoor fan error

Connected indoor unit abnormal

Outdoor unit computer communication
error

Indoor fan abnormal

Discharge temperature error

Excessive high pressure protection on
cooling

4-way valve abnormal

Pressure switch abnormal

Compressor temperature error

Active filter abnormal

PFC circuit error

Error contents

OPERATION

lamp (RED)

(2 times) 

(2 times) 

(2 times) 

(2 times) 

(3 times) 

(3 times) 

(3 times) 

(3 times) 

(3 times) 

(3 times) 

(3 times) 

(3 times) 

(4 times) 

(4 times) 

(5 times) 

(5 times) 

(5 times) 

(5 times) 

(5 times) 

(5 times) 

(6 times) 

(7 times) 

(7 times) 

(7 times) 

(7 times) 

(7 times) 

(8 times) 

(8 times) 

TIMER lamp

(GREEN)

(8 times) 

(2 times) 

(3 times) 

(4 times) 

(6 times) 

(2 times) 

(3 times) 

(4 times) 

(7 times) 

(8 times) 

(2 times) 

(4 times) 

(2 times) 

(3 times) 

(5 times) 

(6 times) 

(7 times) 

(8 times) 

(2 or 3 times) 

(2 times) 

(3 times) 

(4 times) 

(5 times) 

(6 times) 

(2 or 3 times) 

(4 times) 

FILTER lamp

(ORANGE)

(2 times) 

(3 times) 

(4 times) 

9378042018_IM_back.p65

22/12/06, 13:19

1

Отзывы: