TROUBLESHOOTING

Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).

In  the  event  of  a  malfunction  (burning  smell,  etc.),  immediately  stop  operation,  disconnect  the 

power supply plug or turn off the circuit breaker, and consult authorized service personnel.

Merely turning off the unit’s power switch will not completely disconnect the unit from the power 

source. Always be sure to disconnect the power supply plug or turn off your circuit breaker to en-

sure that power is completely off.

Before requesting service, perform the following checks:

WARNING

Symptom

Problem

See page

NORMAL

FUNCTION

Does not operate  

immediately:

  If the unit is stopped and then immediately started again, the 

compressor will not operate for about 3 minutes, in order to 

prevent fuse blowouts.

  Whenever the power supply plug is disconnected and then 

reconnected to a power outlet, the protection circuit will oper-

ate for about 3 minutes, preventing unit operation during that 

period.

Noise is heard:

  During operation and immediately after stopping the unit, the 

sound of water flowing in the air conditioner’s piping may be 

heard. Also, noise may be particularly noticeable for about 2 

to  3  minutes  after  starting  operation  (sound  of  coolant  flow-

ing).

  During  operation,  a  slight  squeaking  sound  may  be  heard. 

This is the result of minute expansion and contraction of the 

front cover due to temperature changes.

*

 

During heating operation, a sizzling sound may be heard oc-

casionally. This sound is produced by the automatic defrosting 

operation.

17

Smells:

  Some smell may be emitted from the indoor unit. This smell is 

the result of room smells (furniture, tobacco, etc.) which have 

been taken into the air conditioner.

Mist or steam are  

emitted:

  During cooling or dry operation, a thin mist may be seen emit-

ted from the indoor unit. This results from the sudden cooling 

of room air by the air emitted from the air conditioner, result-

ing in condensation and misting.

*

 

During heating operation, the outdoor unit’s fan may stop, and 

steam may be seen rising from the unit. This is due to the au-

tomatic defrosting operation.

17

Airflow is weak or stops:

*

 

When  heating  operation  is  started,  fan  speed  is  temporarily 

very low, to allow internal parts to warm up.

*

 

During heating operation, if the room temperature rises above 

the  thermostat  setting,  the  outdoor  unit  will  stop,  and  the 

indoor unit will operate at very low fan speed. If you wish to 

warm the room further, set the thermostat to a higher setting.

*

 

During  heating  operation,  the  unit  will  temporarily  stop  op-

eration (Max. 15 minutes) as the automatic defrosting mode 

operates. During the automatic defrosting operation, the OP-

ERATION indicator lamp will flash.

17

  The fan may operate at very low speed during dry operation 

or when the unit is monitoring the room’s temperature.

  During SUPER QUIET operation, the fan will operate at very 

low speed. 

  In  the  monitor AUTO  operation,  the  fan  will  operate  at  very 

low speed.

Water is produced from the 

outdoor unit:

*

 

During  heating  operation,  water  may  be  produced  from  the 

outdoor unit due to the automatic defrosting operation. 

17

The ECONOMY indicator 

lamp flashing: 

  Clean  the  filter. Afterwards,  turn  the  ECONOMY  indicator 

lamp off.

14

9374379590-02_OM_en.indb   15

22/2/2556   17:02:53

Содержание 45

Страница 1: ...AIR CONDITIONER English PART NO 9374379590 02 OPERATING MANUAL Ceiling Suspension Type Keep this manual for future reference FUJITSU GENERAL LIMITED 9374379590 02_OM_en indb 1 22 2 2556 17 02 49 ...

Страница 2: ...ended periods Always turn off the electrical breaker whenever cleaning the air conditioner or changing the air filter Connection valves become hot during Heating handle with care When restarting after a long period of disuse in the winter turn the power switch on at least 12 hours before starting the unit Check the condition of the installation stand for damage Do not place animals or plants in th...

Страница 3: ... under cooling mode and lower than set temp under heating mode Therefore the ECONOMY mode is able to save more energy than other normal mode OMNI DIRECTIONAL AIR FLOW SWING OPERATION 3 dimensional control over air direction swing is possible through dual use of both an up down air direction swing and right left air direction swing Since up down air direction flaps operate automatically according t...

Страница 4: ...HEAT operation controlled by wire less remote controller 7 Intake grille 8 Up down air direction flaps 9 Right left air direction louvers behind up down air direction flaps 3 2 1 9 8 7 4 5 6 FEATURES AND FUNCTIONS Indoor unit n Remote controller WIRELESS REMOTE CONTROLLER The wireless remote controller allows convenient control of air conditioner operation WIRED REMOTE CONTROLLER OPTION The option...

Страница 5: ...mer mode indicator N Clock indicator Some indoor units may not be equipped with the func tions corresponding to all of the buttons on this remote controller The indoor unit will beep and the OPERA TION TIMER and ECONOMY lamp flash when a remote controller button is pressed if the function is not avail able Remote controller Display NAME OF PARTS This button is used when installing the conditioner ...

Страница 6: ...the direction of the arrow while pressing the mark Batteries are not included with this product 2 Insert batteries Be sure to align the battery polarities correctly 3 Close the battery compartment lid Set the Current Time 1 Press the CLOCK ADJUST button Use the tip of a ball point pen or other small object to press the button 2 Use the TIMER SET buttons to adjust the clock to the current time butt...

Страница 7: ...essed the fan speed changes in the following order AUTO HIGH MED LOW QUIET About 3 seconds later the entire display will reappear When set to AUTO Heating Fan operates so as to optimally circulate warmed air However the fan will operate at very low speed when the temperature of the air issued from the indoor unit is low Cooling As the room temperature approaches that of the thermostat setting the ...

Страница 8: ...ges the indoor unit will once again select the appropriate operation cooling to adjust the temperature to the value set in the temperature setting If the mode automatically selected by the unit is not what you wish select one of the mode operation COOL DRY FAN Mode operation During heating mode Set the thermostat to a temperature set ting that is higher than the current room temperature The heatin...

Страница 9: ...et the time while the time display is flashing the flashing will continue for about 5 seconds button Press to advance the time button Press to reverse the time About 5 seconds later the entire display will reappear To Use the Program Timer 1 Press the START STOP button if the unit is already operating proceed to step 2 The indoor unit s OPERATION indicator lamp green will light 2 Set the desired t...

Страница 10: ...C 2 C 2 C 3 C 4 C 30 minutes 1 C 1 hour 1 hour 30 minutes Set time During cooling dry operation When the SLEEP timer is set the thermostat setting is auto matically raised 1 C every 1 hour When the thermostat has been raised a total of 2 C the thermostat setting at that time is maintained until the set time has elapsed at which time the air conditioner automatically turns off SLEEP timer setting D...

Страница 11: ...e up down left and right air directions with the SET buttons on the remote controller Use the SET buttons after the indoor unit has started operating and the airflow direction louvers have stopped moving Vertical Air Direction Adjustment Press the SET button Vertical Each time the button is pressed the air direction range will change as follows 1 2 3 4 5 Types of Airflow Direction Setting 1 2 3 Du...

Страница 12: ... conditioner operation before performing this procedure To Use the ECONOMY Operation Press the ECONOMY button The ECONOMY indicator lamp green will light ECONOMY operation begins To Stop the ECONOMY Operation Press the ECONOMY button again The ECONOMY indicator lamp green will go out Normal operation begins About ECONOMY Operation At the maximum output ECONOMY operation is approximately 70 of norm...

Страница 13: ...r signal code is set to A prior to shipment Contact your retailer to change the signal code The remote controller resets to signal code A when the batteries in the remote controller are replaced If you use a signal code other than signal code A reset the signal code after replacing the batteries If you do not know the air conditioner signal code setting try each of the signal codes until you find ...

Страница 14: ...installer or an accredited technical assistance When used for extended periods the unit may accumulate dirt inside reducing its performance We recommend that the unit be inspected regularly in addition to your own cleaning and care For more information consult authorized service personnel It is recommended for the user consumer to demand a copy of the Work Order every time there is a visit of a te...

Страница 15: ...rosting operation 17 Smells Some smell may be emitted from the indoor unit This smell is the result of room smells furniture tobacco etc which have been taken into the air conditioner Mist or steam are emitted During cooling or dry operation a thin mist may be seen emit ted from the indoor unit This results from the sudden cooling of room air by the air emitted from the air conditioner result ing ...

Страница 16: ...t to enter Close the curtains In the case of cooling operation are there heating apparatus and computers inside the room or are there too many people in the room Is the unit set for QUIET operation The unit operates differ ently from the remote con troller setting Are the remote controller batteries dead Are the remote controller batteries loaded properly 6 TROUBLESHOOTING If the problem persists ...

Страница 17: ...only to HEAT COOL MODEL Reverse Cycle Should the power supply to the air conditioner be inter rupted by a power failure the air conditioner will restart automatically in the previously selected mode once the power is restored Should a power failure occur during TIMER operation the timer will be reset and the unit will begin or stop operat ing under the new timer setting In this event the TIMER ind...

Страница 18: ...9374379590 02_OM_en indb 18 22 2 2556 17 02 53 ...

Отзывы: