46
Model
48
R
L
X
F
Z
ASU
Wall Mount
BTUs in
thousands
R =
Reverse cycle
heat pump
C =
Cassette
L =
Inverter
S =
Super
Efficient
Z=
Zone
ABU
Universal Mount
Ceiling Suspended
C =
Cooling only
S =
Ceiling
Suspended
X =
Extended
Line Set
X =
Extended
Line Set
W=
Wall
Mount
Only
ARU
Compact Duct
L =
Inverter
S =
Super
Efficient
S =
Super
Efficient
AUU
Cassette Mount
U =
Universal
F =
HFI
F =
HFI
AOU
Outdoor Unit
H =
High
Heating
W =
Wall
Mount
Only
C =
Compact
Cassette or
Compact
Duct
Fujitsu Model Nomenclature
While these systems share indoor units, different line sizes are required.
Line Set Sizes and Lengths
1/4” x 3/8”
1/4” x 1/2”
1/4” x 5/8”
3/8” x 1/2”
3/8” x 5/8”
Total System
Max.
Combined
Pipe Length ft (m)
66
(20)
66
(20)
66
(20)
66
(20)
66
(20)
66
(20)
66
(20)
66
(20)
66
(20)
66
(20)
66
(20)
165
(50)
165
(50)
66
(20)
165
(50)
165
(50)
165
(50)
66
(20)
66
(20)
66
(20)
66
(20)
66
(20)
66
(20)
165
(50)
165
(50)
165
(50)
165
(50)
165
(50)
165
(50)
230
(70)
Min.
Combined
Pipe Length ft (m)
9
(2.7)
9
(2.7)
9
(2.7)
9
(2.7)
9
(2.7)
9
(2.7)
9
(2.7)
9
(2.7)
9
(2.7)
9
(2.7)
9
(2.7)
16
(5)
16
(5)
9
(2.7)
16
(5)
16
(5)
16
(5)
9
(2.7)
9
(2.7)
9
(2.7)
9
(2.7)
9
(2.7)
9
(2.7)
16
(5)
16
(5)
16
(5)
16
(5)
16
(5)
16
(5)
16
(5)
Single Zone Systems
9RL2
9RLFW
9RLS2
9RLS2H
12RL2
12RLFW
12RLS2
12RLS2H
15RLS2
15RLS2H
18CL
18RLXFW
24RLXFW
24CL1
30CLX1
30RLX
36CLX1
9RLFCD
12RLFCD
18RLFCD
9RLFCC
12RLFCC
18RLFCC
18RULX
24RULX
36RSLX
18RCLX
24RCLX
36RCLX
42RCLX
*18+18 is the only 2 indoor unit combination allowed for AOU36RLXFZ and requires kit K9FZ1818.
While these systems share indoor units, different line sizes are required.
^ Line set size from outdoor unit AOU48RLXFZ1 to the branch boxes.
1
Minimum combined pipe length from outdoor unit to branch box.
2
Minimum combined pipe length from branch box to indoor unit each.
1/4” x 3/8”
1/4” x 1/2”
1/4” x 5/8”
3/8” x 1/2”
3/8” x 5/8”
Total System
Max.
Combined
Pipe Length ft (m)
165
(50)
165
(50)
230
(70)
131
(40)
377
(115)
Min.
Combined
Pipe Length ft (m)
49
(15)
49
(15)
66
(20)
49
(15)
16
1
10
2
(5)
1
(3)
2
Each Indoor Unit
Minimum and maximum pipe lengths for multi-zone units are found on pages 36, 37 and 41.
Multi / Flex Zone Models
ASU7RLF
ASU9RLF
ASU9RLS2
ASU12RLF
ASU12RLS2
ASU15RLS2
ASU18RLF
ASU24RLF
ARU9RL
ARU12RLF
ARU18RLF
ARU24RLF
AUU9RLF
AUU12RLF
AUU18RLF
ASU18RLF x 2*
ARU18RLF x 2*
AUU18RLF x 2*
UTP-PU03A
/3B^
AOU18RLXFZ
AOU24RLXFZ
AOU36RLXFZ
AOU36RLXFZ
(18+18)
AOU48RLXFZ1
MISCELLANEOUS