FSC B17-2
Page 40 of 55
9.White-blance, Lminance adjustment
Approximately 30 minutes should be allowed for warm up before proceeding White-Balance adjustment.
1. How to do the Chroma-7120 MEM. Channel setting
A. Reference to chroma 7120 user guide
B. Use “
SC
” key and “
NEXT
” key to modify XyY value and use “
ID
” key to modify the
TEXT description Following is the procedure to do white-balance adjust
2. Setting the color temp. you want
A. MEM.CHANNEL 3 (9300 color):
7800 color temp. parameter is x = 283 ±15, y = 297 ±15
,
B. MEM.CHANNEL 4 (6500 color):
6500 color temp. parameter is x = 315±15, y = 325 ±15.
3. into factory mode of B17-2
Press MENU button during 2 seconds along with press Power button will activate the factory mode, then MCU will do
AUTO LEVEL automatically. Meanwhile press MENU the OSD screen will be located at
LEFT TOP OF PANEL
.
4. Bias adjustment:
Set the
Contrast
to 100; adjust the
Brightness
to100.
5. Gain adjustment:
Move cursor to “-F-” and press MENU key
A. Adjust C2 (9300) color-temperature
1. Switch the Chroma-7120 to
RGB-Mode
(with press “MODE” button)
2. Switch the MEM. Channel to Channel 3 (with up or down arrow on chroma 7120)
3. The LCD-indicator on chroma 7120 will show x = 283 ±15, y = 297 ±15, Y = 180 cd/m
2
4. Adjust the RED of color1 on factory window until chroma 7120 indicator reached the value R=100
5. Adjust the GREEN of color1 on factory window until chroma 7120 indicator reached the value G=100
6. Adjust the BLUE of color1 on factory window until chroma 7120 indicator reached the value B=100
7. Repeat above procedure (item 4,5,6) until chroma 7120 RGB value meet the tolerance =100±2
B. Adjust C1 (6500) color-temperature
1. Switch the chroma-7120 to
RGB-Mode
(with press “MODE” button)
2. Switch the MEM. channel to Channel 4(with up or down arrow on chroma 7120)
3. The LCD-indicator on chroma 7120 will show x = 315±15, y = 325 ±15, Y = 180 cd/m
2
4. Adjust the RED of color3 on factory window until chroma 7120 indicator reached the value R=100
5. Adjust the GREEN of color3 on factory window until chroma 7120 indicator reachedthe value G=100
6. Adjust the BLUE of color3 on factory window until chroma 7120 indicator reached the value B=100
7. Repeat above procedure (item 4,5,6) until chroma 7120 RGB value meet the tolerance =100±2
C. Turn the Power-button off to quit from factory mode.
Содержание B17-2
Страница 3: ...FSC B17 2 Page 3 of 55 11 BOM LIST 42 ...
Страница 8: ...FSC B17 2 Page 8 of 55 ...
Страница 9: ...FSC B17 2 Page 9 of 55 ...
Страница 10: ...FSC B17 2 Page 10 of 55 ...
Страница 15: ...FSC B17 2 Page 15 of 55 4 4 3 BACKLIGHT UNIT ...
Страница 16: ......
Страница 17: ...FSC B17 2 Page 17 of 55 5 BLOCK DIAGRAM 5 1 MONITOR EXPLODED VIEW ...
Страница 31: ...FSC B17 2 Page 31 of 55 7 PCB LAYOUT 7 1 MAIN BOARD ...
Страница 32: ...FSC B17 2 Page 32 of 55 7 2 KEY BOARD 7 3 PWPC BOARD ...