background image

6

1. PREPARATION

WARNING

If the range hood is not installed properly, it could become detached and fall off.

Ensure that the metal duct does not touch other metal housing materials,
otherwise fire or electric shock could result.

1

This range hood can discharge upward
or backward. According to the conditions
where the hood is installed, determine
whether it will discharge vertically or
horizontally (3¼" 

×

 10" duct).  For vertical

or horizontal discharge, run duct work
between the hood location and a roof
cap or wall cap.
For the best results in either directions,
use a minimum number of transitions
and elbows. Be sure to attach a roof cap
or wall cap to avoid leaking rain in the
end.

2

The range hood unit must be mounted to a liner which has the following
dimensions. Install the liner securely after checking that the opening size of the
liner is the same as the figure below.

INSTALLATION

CAUTION

The liner should be installed tightly. If the liner installation is not correct, the range
hood unit may become detached and fall off.

Содержание BUF-03R

Страница 1: ...CO LTD TABLE OF CONTENTS Safety Instructions 2 Name of Parts 4 Size Dimensions 4 Range Hood Location 5 Installation 6 1 Preparation 6 2 Range Hood Mounting 9 3 Connecting Power Supply Wires 11 4 Final Assembly and Check 13 5 Explanation to the End User 14 Circuit Diagram 14 Installation Manual RANGE HOOD MODEL BUF 03R ...

Страница 2: ...y When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel 2 To reduce the risk of fire or electric shock do not use this product with any solid state speed control device 3 TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING a Installation work and electrical wiring must be done by a qualif...

Страница 3: ... Do not vent exhaust air into spaces within walls ceilings or into attics crawl spaces or garages 6 Fasten the filter and other parts securely Incorrect attachment may result in personal injury or property damage 4 Use only for the purpose of kitchen ventilation 1 For general ventilating use only Do not use to exhaust hazardous or explosive material and vapors 7 Keep your hands and other objects a...

Страница 4: ...4 NAME OF PARTS SIZE DIMENSIONS Accessories Accessories Accessories Accessories Accessories Unit inch Screw M5 30 Four 4 pieces Nut with plate Four 4 pieces ...

Страница 5: ...weight of the BUF 03R range hood unit is BUF 03R 18 lbs 8 kg 4 Power requirements are AC120 V 60 Hz 1 8 Amp RANGE HOOD LOCATION CAUTION Check that the hood is correctly installed since incorrect installation could result in the detachment of the range hood and the unit could fall off To protect hands from injury wear working gloves when installing the range hood ...

Страница 6: ... vertical or horizontal discharge run duct work between the hood location and a roof cap or wall cap For the best results in either directions use a minimum number of transitions and elbows Be sure to attach a roof cap or wall cap to avoid leaking rain in the end 2 The range hood unit must be mounted to a liner which has the following dimensions Install the liner securely after checking that the o...

Страница 7: ...ith the exhaust pipe fixed on its top plate 2 Provide a transition duct not supplied to connect the exhaust pipe and external duct For the size of transition duct refer to Fig at right 3 Be sure to keep 1 3 16 overlapping length of the exhaust pipe and transition duct when installing 4 Skip to page 9 for mounting the range hood INSTALLATION continued ...

Страница 8: ... and attach it as shown in Fig 4 Attach the range hood to the liner Refer to page 9 for details 5 Connect the exhaust pipe with the duct then make the duct joint secure and air tight using non flammable tape such as duct tape etc not supplied 6 Attach the exhaust pipe to the range hood with 4 screws M4 8 from out side of the wall 7 Connect the duct to out side wall cap not supplied CAUTION To prev...

Страница 9: ...h sides have passed through the top of the liner turn them outward to secure the range hood on the liner temporarily Make sure that the top of the exhaust pipe is inserted into the bottom of the transition duct INSTALLATION continued 2 Remove 4 screws which are fixed to the front cover The front cover swings open 90 as shown in Fig ...

Страница 10: ...careful not to damage the hinge part 4 Align 4 screw holes of the liner and range hood unit then fix securely using the supplied screws M5 30 and nuts NOTE Fasten all screws and nuts evenly 5 Make the duct joint secure and air tight using non flammable tape such as duct tape etc not supplied NOTE Make sure that the shutter installed in the exhaust pipe moves freely 1 2 ...

Страница 11: ... electric shock or injury This range hood uses 120V AC Do not connect to other voltage since fire electric shock or damage could result 1 Remove the nut from the conduit connector at the end of power wiring WARNING Be sure to switch power OFF at service panel before wiring 2 Remove one screw fixing the wire cover and detach it 3 Connect the conduit through the connecting hole of the body using the...

Страница 12: ... Connect wires tightly and securely using wire connectors not supplied Black to Black White to White Green to Green 5 Replace the wire cover with the screw removed previously Make sure that all wires are connected properly and enclosed inside of the wiring compartment ...

Страница 13: ... the screws with the torque of 13 inch lbs 1 5 N m or less Be sure to connect the wire connector rightly Otherwise the range hood won t work properly 2 Check 1 Turn on the electrical circuit to the range hood 2 Make sure that the switch and light operate correctly Refer to page 4 of the Operation Manual 3 Check the ventilating functions at Hi Me and Lo positions 4 Make sure that the range hood has...

Страница 14: ...The Installation Manual and Operation Manual should be given to the end user INSTALLATION continued CIRCUIT DIAGRAM Motor Connector Connector Terminal Capacitor Red Red Red White White Orange Brown Blue White Orange Brown Blue Green Green Black Black White Orange Brown Blue Green Black 120V 60Hz Bulb Max40W Control Switch ...

Страница 15: ...Fuji Industrial USA Inc 16300 Christensen Rd Ste 212 Seattle WA 98188 3403 Telephone 1 888 547 9880 ...