41S_Rev00
17
Basic Operation
Battery Operation
Check the remaining battery capacity. If it is 20% or less before operation, splicer can only
work a few times.
How to charge the battery
Charge of battery pack BTR-11 is started where AC adaptor ADC-19A is connected to
an inlet. The charge LED (orange) blink and battery charging starts. It takes about 4
hours to charge the battery and the turn off the LED. Pull out the plug of AC power
cord after charging. It is possible to use the splicer during operation.
*1 When LED blinks at the time of charge it is too early and degradation of a battery and failure
can be considered. Charge is not performed. Exchange for New BTR-11.
Power supply ON state
Power supply OFF state
Normal
LED : ON green
Check the battery
capacity
LED : OFF
Charging
Battery icon
operates
4 hours to charge
the battery
LED:Blink orange
4 hours to charge
the battery
LED: Orange Blink quickly(OFF state)
Refer to *1
Keep below practices to prevent battery damage.
The capacity of the battery gradually decreases as nature even if it is not
used. If the battery discharges completely, the battery may no longer be able
to be re-charged. Charge the battery before long time storage and after every
use.
If a battery is to be stored for a long time, periodical charge of every six
months is recommended regardless of battery charge level of the battery.
Follow below conditions
Operation
: -10 degree C ~ 50 degree C
Charging
: 0 degree C ~ 40 degree C
Storage
: -20 degree C ~ 30 degree C
Charge will be started if a power supply is
supplied from ADC-19A.
Please check the charge state in main part
sheet key LED.