CR-IR 362
Service Manual
Appx IN-21
Appx IN-21
011-207-07E
02.19.2007 FM5097
Appendix 6. Procedures for Upgrading
the XG2000 to the XG5000
The procedures are used in upgrading the XG2000 to the XG5000. The following
operations are required:
- Removing the front shutter covers which close the cassette inserting entrances on
the third and fourth shelves.
- Replacing the filters on the shelf covers (on the third and fourth shelves).
- Removing the shock absorbers
- Replacing the product label
- Updating the RU software version
1. Removal and Replacement of Components
n
Removal and Replacement Procedures
1.
Remove the covers.
- Upper front cover
- Lower front cover
{MC:3.1
_Covers}
2.
Remove the shelf cover (on the fourth shelf) and the front shutter
cover.
{MC:24.2
_Front Shutter Cover (Fourth Shelf)}
3.
Remove the shutter assembly from the fourth shelf.
{MC:5.5
_Shutter Assembly (for the Fourth Shelf)}
4.
Remove the shutter assembly from the third shelf.
{MC:5.4
_Shutter Assemblies (for the Second and Third Shelves)}
5.
Remove the shelf cover (on the third shelf) and the front shutter cover
(on the third shelf).
{MC:24.1
_Front Shutter Cover (Third Shelf)}
6.
Remove the shock absorbers.
Содержание CR-IR 362