FUJIDENZO PAC-100AIG Скачать руководство пользователя страница 9

Window Installation Kit

Or

Step Two: Install the Exhaust hose assembly to 
the unit 

 Installation

Instructions

Type window installation

Type wall installation

Type window installation

Type wall installation

Press the exhaust hose (or extended exhaust hose) 
into the window slider adaptor (or wall exhaust 
adaptor) and unit adaptor, clamp automatically by 
elastic buckles of the adaptors.

Step One: Preparing the Exhaust Hose assembly

Exhaust hose

Extended Exhaust 

hose

Exhaust hose assembly

Exhaust hose

Extended Exhaust 
hose

Exhaust hose assembly

Unit adaptor Window slider 

adaptor

Exhaust hose

Exhaust hose 
assembly

Exhaust hose 
assembly

Unit adaptor Wall exhaust 

adaptor A

Exhaust hose

Push the Exhaust hose into the airoutlet opening of 
the unit along the arrow direction.

Other Regions

 Name of Accessories

Qty. 

Shape

 Name of Accessories

Qty. 

Shape

1 pc(*)

Window Slider A

Bolt

1 pc

1 set(*)

Unit Adaptor 

Security Bracket and 2 Screws

1 pc

1 pc

Exhaust Hose

Drain Hose

1 pc(*)

Window Slider Adaptor

O

N

/O

F

F

T

E

M

P

S

H

O

R

T

   

C

U

T

T

IM

E

R

  O

N

T

IM

E

R

  O

F

F

M

O

D

E

FA

N

S

LE

E

P

S

W

IN

G

LE

D

1 set(*)

1 pc(*)

Window Slider B

Remote Controller and Battery
(only for remote control models)

1 pc(*)

Wall Exhaust Adaptor A
 (only for wall installation models) 

2 pc(*)

Foam Seal A (Adhesive)

1 pc(*)

Wall Exhaust Adaptor B(with cap)
(only for wall installation models)

2 pc(*)

Foam Seal B (Adhesive)

4 set(*)

Screw and anchor
 (only for wall installation models)

1 pc(*)

Foam Seal C (Non-adhesive)

1 pc(*)

Drain Hose Adaptor
(only for heat pump mode)

1 pc(*)

1 pc(*)

1 pc(*)

Exhuast Hose Adaptor

Extended Exhuast Hose

 Page 9

Содержание PAC-100AIG

Страница 1: ...ITIONER Owner s Manual Installation Manual IMPORTANT NOTE Read this manual carefully before installing or operating your new air conditioning unit Make sure to save this manual for future reference PAC 100AIG PAC 150AIG ...

Страница 2: ...recautions Air Filter Cleaning Troubleshooting Tips Unit Cleaning Store the unit when not in use Preparation Design Notice Energy Rating Information Ambient Temperature Range For Unit Operating Exhaust Hose Installation Choosing The Right Location Tools Needed Accessories Window Installation Kit Installation Troubleshooting Tips 03 11 11 12 11 11 12 13 13 14 15 17 18 18 20 20 20 20 21 ...

Страница 3: ...re and injury or property damage Make sure that the outlet you are using is grounded and has the appropriate voltage The power cord is equipped with a three prong grounding plug to protect against shock Voltage information can be found on the nameplate of the unit Your unit must be used in a properly grounded wall receptacle If the wall receptacle you intend to use is not adequately grounded or pr...

Страница 4: ...es or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance Children must be supervised around the unit at all times applicable for other countries except the European Countries If the supply cord is damaged it m...

Страница 5: ...the user When buying a new product the retailer will take back the old product at least free of charge The manufacture will take back the old appliance for disposal at least free of charge to the user As old products contain valuable resources they can be sold to scrap metal dealers Wild disposal of waste in forests and landscapes endangers your health when hazardous substances leak into the groun...

Страница 6: ... using an un extended exhaust duct without window slider adaptor as shown in the Installation section of this manual At the same time the unit must be operate on the COOL MODE and HIGH FAN SPEED by remote controller Cool 17 35 C 62 95 F Dry Heat pump heat mode Heat electrical heat mode 13 35 C 55 95 F 5 30 C 41 86 F Installation Instructions rear front control panel remote signal receptor handle b...

Страница 7: ...What should I look first when purchasing a portable air conditioner The right air conditioner helps you cool a room efficiently An undersized unit won t cool adequately while one that s too large will not remove enough humidity leaving the air feeling damp To find the proper air conditioner determine the square footage of the room you want to cool by multiplying the room length by its width You al...

Страница 8: ...acity lower on newer models than on older units number means more cooling power for a larger room Be sure you are comparing only newer models to each other older models may appear to have a higher capacity but are actually the same Be sure to size up if your portable air conditioner will be placed in a very sunny room in a kitchen or in a room with high ceilings After you ve found the right coolin...

Страница 9: ...hose Push the Exhaust hose into the airoutlet opening of the unit along the arrow direction Other Regions Name ofAccessories Qty Shape Name ofAccessories Qty Shape 1 pc Window Slider A Bolt 1 pc 1 set Unit Adaptor Security Bracket and 2 Screws 1 pc 1 pc Exhaust Hose Drain Hose 1 pc Window Slider Adaptor O N O F F T E M P S H O R T C U T T IM E R O N T IM E R O F F M O D E FA N S LE E P S W IN G LE...

Страница 10: ...ation methods Or Foam seal B Adhesive type shorter Foam seal A Adhesive type Type 1 Hang Window or Sliding Window Installation For some models 1 Cut the adhesive foam seal A and B strips to the proper lengths and attach them to the window sash and frame as shown Foam seal B Adhesive type shorter Foam seal A Adhesive type Or Or Window slider A Window slider B if required Foam seal C Non adhesive ty...

Страница 11: ... or 47 inch min 30cm or 12 inch Expansion anchor position Adaptor cap Wall Exhaust Adaptor B Installation Instructions Or Or 2 Screws Security Bracket 4 If desired install the security bracket with 2 screws as shown 5 Insert the window slider adaptor into the hole of the window slider 2 Screws Security Bracket Type 2 Wall Installation For some models 1 Cut a 125mm 4 9inch hole into the wall for th...

Страница 12: ...ntroller LED display Shows the set temperature while on cool heat or auto mode While on DRY and FAN modes it shows the room temperature Shows Error codes E0 EEPROM error E1 Room temperature sensor error E2 Evaporator temperature sensor error E3 Condenser temperature sensor error on some models E4 Display panel communication error EC Refrigerant leakage detection malfunction on some models Shows pr...

Страница 13: ...odels Used to initiate the wireless connection mode For the first time to use wireless function press the mode button for 3 seconds to initiate the wireless connection mode when the unit is off The LED DISPLAY shows AP to indicate you can set wireless connection If connection router is successful within 8 minutes the unit will exit wireless connection mode automatically and the wireless indicator ...

Страница 14: ...uous drain hose NOTE Make sure the hose is secure so there are no leaks Direct the hose toward the drain making sure that there are no kinks that will stop the water flowing Place the end of the hose into the drain and make sure the end of the hose is down to let the water flow smoothly When the continuous drain hose is not used ensure that the drain plug and knob are installed firmly to prevent l...

Страница 15: ...he unit using a damp lint free cloth and mild detergent Dry the unit with a dry lint free cloth Drain the unit s water collection tray according to the instructions in the following section Run the appliance on FAN mode for 12 hours in a warm room to dry it and prevent mold Turn off the appliance and unplug it Clean the air filter according to the instructions in the previous section Reinstall the...

Страница 16: ... to inspect the unit and top off refrigerant Decrease the set temperature Make sure all windows and doors are closed Double check the cooling area Turn off the unit disconnect the hose check for blockage and reconnect the hose Remove the heat sources if possible The unit is noisy and vibrates too much The unit makes a gurgling sound The ground is not level Place the unit on a flat level surface Th...

Страница 17: ......

Страница 18: ......

Страница 19: ...ications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details Any updates to the manual will be uploaded to the service website please check for the latest version ...