- 22 -
INZ-TN7ZSS-E
4.7.3 Adjustment procedure
4.7.3.1 When an optical axis adjusting tool (laser pointer) is used
Do not watch the laser pointer beam directly with the optical measuring
device. Otherwise, it may cause serious damage to your eyes.
(1) When A and B flanges shown in Fig. 4
4 are extremely tilted, adjust them in a flat place so that they
are parallel to each other. Refer to “4.7.1 How to operate the angle adjustment unit 1” before mounting
the stack unit.
(2) Mount the angle adjustment unit to the companion flange on the stack.
When mounting it, be careful of the direction of the fixing bolts so as to be as shown in Fig. 4
them at this time so that the outer circumferences of the companion flange on the stack side and the
flange on the angle adjustment unit coincide as much as possible. (Do not yet mount the receiver box
and the transmitter box.)
(3) Fix the laser pointer on the transmitter unit side and the laser scope on the receiver unit with the at-
tached hexagonal socket screws. (The laser pointer has two kinds of holes at different distance from the
center. Position the laser pointer so that it matches the angle adjustment mechanical section, and fix it
with three screws.)
(4) Emit light from the laser pointer, and adjust the angle adjustment unit while referring to “4.7.2 How to
operate the angle adjustment unit 2” so that the pointer’s light hits the center of the target.
(5) Then using the attached hexagonal socket screws to fix the laser pointer to the angle adjustment unit on
the receiver unit, and the laser scope to the angle adjustment unit on the transmitter unit.
(6) Adjust as well as (4).
(7) When you have finished adjustment, retighten the fixing bolts and nuts lightly. When retightening the
bolts and nuts, take care not to move the light axis. Remove the laser pointer and the target.
4.7.3.2 When an optional optical axis adjusting tool (laser pointer) is not used
(1) When A and B flanges shown in Fig. 4
4 are extremely tilted, adjust them in a flat place so that they
are parallel to each other. Refer to “4.7.1 How to operate the angle adjustment unit 1” before mounting
the stack unit.
(2) Mouth the angle adjustment unit to the companion flange on the stack.
Fig. 4
-
8
When mounting it, be careful of the direction of the fixing bolts on the angle adjustment unit so as to be
as to be shown in Fig. 4
8. Fix them at this time so that the outer circumferences of the companion
flange on the stack side and the flange on the angle adjustment unit coincide as much as possible. After
fixing them, mount the receiver box and the transmitter box, referring to “4.9 Assembly of receiver unit
and transmitter unit”.
(3) Adjust the optical axis, referring to “4.11.2 When an optional optical axis adjusting tool (laser pointer)
CAUTION
Angle adjustment unit
Receiver box
Fixing bolt