![Fuji Electric ROM-32N Скачать руководство пользователя страница 2](http://html.mh-extra.com/html/fuji-electric/rom-32n/rom-32n_service-manual_2341731002.webp)
S P E C I F I C A T I O N S
TYPE
COOL
OPERATION
UNIT A1 or A2
3 UNITS
UNIT B
INDOOR UNIT
RSWM-17M, RSWM-17CM
RSWM-12M, RSWM-12CM
UNIT A1 + A2 + B
OUTDOOR UNIT
ROM-32N
COOLING CAPACITY
(kW)
4.70 - 4.75
3.24 - 3.28
9.15 - 9.30
1,650
1,150
1,650 + 1,150
8.3 - 8.2
1.80 - 1.88
2.61 - 2.53
2.0
6.8 - 6.8
1.42 - 1.50
2.28 - 2.19
1.3
495
3,320 (OUTDOOR UNIT)
560
15.4 - 15.2
3.32 - 3.45
2.76 - 2.70
3.3
POWER SOURCE
(V)
220 - 240
FREQUENCY
(Hz)
50
RUNNING CURRENT
(A)
INPUT WATTS
(kW)
EER
(kW/kW)
MOISTURE REMOVAL
( /hr)
AIR CIRCULATION-Hi
(m
3
/hr)
ELECTRICAL DATA
COMPRESSOR
DIMENSIONS
TYPE
Hermetic type, Permanent split condenser,
2 Pole, Single phase, Induction motor
CODE
PH33VTTT
220 - 240V 50Hz
RH231VHAT
220 - 240V 50Hz
REFRIGERANT
R-22
(g)
POWER SOURCE
(V)
240
HI-SPEED
(r.p.m.)
1,330
INDOOR UNIT
MED-SPEED (r.p.m.)
1,250
LO-SPEED
(r.p.m.)
1,170
1,300
1,210
1,130
QUIET
(r.p.m.)
1,080
OUTDOOR UNIT
(r.p.m.)
730
INDOOR UNIT
H x W x D
260 x 815 x 175
285 x 900 x 172
OUTDOOR UNIT
(mm)
900 x 900 x 350
FAN MOTOR
WEIGHT
INDOOR UNIT
GROSS / NET
(kg)
10 / 8
13 / 10
OUTDOOR UNIT
97 / 85
1