RMA-C1-2.2/RMA-C1-3.7
Installing the rail mounting base to your FRENIC-Mini
1) As illustrated in Figure 4, set the FRENIC-Mini on the rail mounting
base with the FRENIC-Mini's bottom facing towards the handle.
2) Secure the FRENIC-Mini to the rail mounting base with four screws
(M4x12) that came with the rail mounting base.
Tightening torque: 1.8 N
m(0.74 lbf
ft)
Installing the rail mounting base with the FRENIC-Mini to the din rail
(
See Figure 2.
)
1) Hook the upper latches of the rail mounting base over the upper edge
of the din rail. The RMA-C1-3.7 has four upper latches, make sure that
all of the four latches catch the upper edge of the din rail.
2) Press the lower end of the FRENIC-Mini against the din rail until the
lower latches of the rail mounting base catch the din rail.
Removing the rail mounting base with the FRENIC-Mini from the din rail
(
See Figure 3.
)
1) While holding the FRENIC-Mini by hand, pull down the handle of the
rail mounting base and pull the lower end of the FRENIC-Mini
towards you to release it from the lower latches of the din rail.
CAUTION Be sure to support the FRENIC-Mini while
removing. Failure to do so might allow the FRENIC-Mini to fall.
2) Lift up the FRENIC-Mini and release the rail mounting base and
FRENIC-Mini from the din rail.
Figure 4
M4x12 screws
(that came with the mounting base)
Handle
Fuji Electric Systems Co., Ltd.
Fuji Electric Corp. of America
Information subject to change without notice.
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]