Fuji Electric PUMCL Скачать руководство пользователя страница 3

- 3 -

- 4 -

Mounting

 

-

Dimensions

1.5

6

30

85

(10)

(8)

(30)

100

5

50

6.1

LOADER

PUM-C

PWR
BUS

L.RUN
L.ERR

SD
RD

STATION No.

7

6

5

4 3 2 1

0

9

8

x10

7

6

5

4 3 2 1

0

9

8

x1

Front screw terminal cover 

(optional)

Main unit (when detached from the base part)

Terminal block

(when detached 

from the 

main unit)

Base part 

(when detached from

the main unit)

(mm)

Terminal

screw 

size M3

Terminal

screw size M3

When locking tab is released 

(when mounting / dismounting to / from DIN rails)

DIN rail

Cautions when mounting

In order to aid heat dissipation, 30mm of clearance (50mm recommended) above and 

under the controllers should be provided.

30 or more

30 or more

 

-

Mounting to DIN rails

1. Pull down the locking tab of the 

base part. Hook the back of the 

controller onto the upper part of 

DiN rail.

2. 

Push the controller in the 

direction of arrow 2.

 

 

 

 

 

 

 

 

3. Push up the locking tab to fasten 

the controller to DIN rail.

 

-

When connecting controllers after 

attaching to DIN rail, push up 

the locking tab after connecting 

controllers.

 

-

Attaching end plates

When attaching controllers to DIN rails, we recommend to attach side connecting 

terminal covers (right and left 1set), then end plates (option) to the ends of the right 

most and left most controllers. 

 

-

Fixing with screws

When mounting controllers inside a cabinet with screws, connect the base parts of 

controllers first.

 

-

Fixing screws are not included. Please prepare screws as required.

1. Refer to the figure below for the mounting 

screw hole size to decide the mounting position.

 

 

 

 

 

 

 

 

 

 

 

 

 

2. 

Remove the main units from the base part. 

See [How to detach the base part]

 

3. Connect base parts.  Push up to fasten all the locking tabs. 

4. Fixate the base parts onto the mounting position inside the cabinet with screws.

 

5. Attach the main units to the base parts.

 

-

Connecting controllers

1. Check that locking tabs are pulled down 

(released).

 

2. Connect controllers with each other using 

side connectors. 

 

 

 

 

 

 

 

 

 

 

 

3. After mounting connected controllers onto 

DIN rail, make sure to push up all locking 

tabs. Controllers are fastened to DIN rail and 

to each other. 

4. 

All connected controllers are connected to 

power supply via side connectors if one of 

controllers is directly connected to them.

Wiring

 

-

Front terminal block 

Vacant

Vacant

LOADER

PUM-C

PWR

BUS

L.RUN

L.ERR

SD

RD

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

STATION No.

7

6

5

4

3

2

1

0

9

8

x10

7

6

5

4

3

2

1

0

9

8

x1

DA

DB

DG

SLD

FG

CC-Link

22

21

23

25

24

Internal Communication
Terminating Resistance
(option)*

* This terminating resistance is different from the CC-Link terminating resistance 
  (this is the terminating resistance for inter-module communication). 
  Install the resistance (100

) supplied with this controller.

12

11

 

-

Base part (power terminal)

DC 24V (‑)

Power Terminal

DC 24V (+)

Note: The power cables more than one should not be connected.

Specification

General Specification

Power Supply 

: DC24V±10%

Power Consumption 

: Maximum 3.2W (135mA) [when DC24V is applied]

Dimensions 

: 30 (W) × 100 (H) × 85 (D) mm (excluding the terminal cover and a 

projection)

Weight 

: Approx. 200 g

Installation method 

: Mounting on the wall or, install in the cabinet with the DIN rail with 

M3 screws

Ambient temperature * 

: -10 to 50 degrees C

 

  * "Ambient temperature" is the temperature underneath the controller 

inside equipment or the cabinet where the controller is installed.

Ambient humidity 

: 90% RH or less (non condensing)

System maximum modules  : Up to max. 17 modules of any Model PUMA/B/C/CL/CM/V/N/T plus 

to max 16 modules of Model PUME

System power 

: 24V dc, 100W maximum, Class 2

Memory backup 

:  Nonvolatile memory (EEPROM) backup

 

  No.of updates : 100,000

Communication function

Compliant version 

: CC-Link Ver.2.00 / 1.10

Station type 

: Remote device station

Communication speed and distance

Communication 

speed

156kbps

625kbps

2.5Mbps

5Mbps

10Mbps

Communication 

distance

1200m or less

900m or less

400m or less

200m or less

100m or less

* For more details, refer to “CC-Link Cable Wiring Manual” issued by CC-Link Partner Association.

No. of stations occupied / Station No.:  4 stations / Settable Station No. 1 to 61

Communication data length

No.of  stations occupied / 

Extended cyclic

Remote input/output

(RX/RY)

Remote register

(RWr/RWw)

Control module

(PUM-A) No. of 

connectable units

4 stations occupied x 1 128 bit each

16 words each

2 or 4 units

4 stations occupied x 2 256 bit each

32 words each

4 or 8 units

4 stations occupied x 4 512 bit each

64 words each

8 or 16 units

Connecting cable 

:  Ver.1.10 compliant CC-Link special cable

Connecting method 

:  M3 screw terminal block

Terminating resistance 

:  External (110 ohm, 1/2W)

Crimp terminal size

Please prepare cables and crimp terminals of the size indicated below.
When using a AWG-16 cable, you should use the crimp terminal that material thickness is 0.9mm 

or less.

Cable type

Size

Thermocouple (Compensation lead wire)

0.25 to 1.25mm

2

 (AWG 22 to 16)

Power supply, output, others

0.25 to 1.25mm

2

 (AWG 22 to 16)

Crimp terminal

Cable size

Screw tightening torque

0.25 to 1.25mm

2

 (AWG 22 to 16)

0.8 N•m

φ

3.2mm

6.

0m

m

 o

r l

es

s

Ring crimp terminal

Y crimp terminal

3.2mm

6.

0m

m

 o

r l

es

s

* Material thickness

  0.9mm or less.

Model code

Enhanced communication module (CC-Link)

1 2 3 4 5 6 7 8

  9 10

P U

1

0

M

Y Y

C

L

A

B

Contents

Module type 

 

 

 

Advanced communication module

Communication function   

 

CC-Link communication

Instruction manual

Japanese
English

Accessories (Optional)

1 2 3 4 5 6 7 8

P U M Z *

A 0 2
A 0 3
A 0 4
L 0 1

Contents

 DIN rail mounting end plate
 Side connecting terminal cover (right & left 1 set)
 Front face screw terminal cover
 Loader connecting cable (RS-232C)

LOADER

PUM-C

LOADER

PUM-A

PWR

COM

OUT1

OUT2

OUT3

OUT4

STATION

4

3

2

1

F

E

D

C

B

A

9

8

7

6

5

Locking tab

Side connector

PWR

BUS

L.RUN

L.ERR

SD

RD

STATION No.

7

6

5

4

3

2

1

0

9

8

x10

7

6

5

4

3

2

1

0

9

8

x1

LOADER

PUM-C

PWR
BUS

L.RUN
L.ERR

SD
RD

LOADER

PUM-A

PWR
COM

OUT1
OUT2

OUT3
OUT4

STATION

4

3

2

1

0

F E D C B A

9

8

76

5

LOADER

PUM-A

PWR
COM

OUT1
OUT2

OUT3
OUT4

STATION

4

3

2

1

0

F E D C B A

9

8

76

5

STATION No.

7

6

5

4 3 2 1

0

9

8

x10

7

6

5

4 3 2 1

0

9

8

x1

(30)

9

0.2

88.5

0.

2

(100)

(3)

30

+0.7

+0.2

2-M3

[mm]

How to detach the base part

1. 

Press the lock lever on the top of the 

controller. 

2. Pull down the upper part of main unit. 

 

3. 

Detach the cutout on the lower end 

of back of the main unit from the 

projection on the base part.

 

-

When attaching the main unit to the 

base part, take the reverse procedure 

to removing the main unit from the 

base part.

 

-

Make sure that the lock lever of the 

main unit is fitted into the base part.

Lock lever

Main

Projection

Locking tab

DIN rail

Hook the back 

of controller

LOADER

PUM-C

LOADER

PUM-E

PWR
COM

STATION

4

3

2

1

0

F E D C B A

9

8

76

5

Di1
Di2
Di3
Di4
Di5
Di6
Di7
Di8

Do1
Do2
Do3
Do4
Do5
Do6
Do7
Do8

LOADER

PUM-E

PWR
COM

STATION

4

3

2

1

0

F E D C B A

9

8

76

5

Di1
Di2
Di3
Di4
Di5
Di6
Di7
Di8

Do1
Do2
Do3
Do4
Do5
Do6
Do7
Do8

LOADER

PUM-E

PWR
COM

STATION

4

3

2

1

0

F E D C B A

9

8

76

5

Di1
Di2
Di3
Di4
Di5
Di6
Di7
Di8

Do1
Do2
Do3
Do4
Do5
Do6
Do7
Do8

LOADER

PUM-A

PWR
COM

OUT1
OUT2

OUT3
OUT4

STATION

4

3

2

1

0

F E D C B A

9

8

76

5

PWR
BUS

L.RUN
L.ERR

SD
RD

STATION No.

7

6

5

4 3 2 1

0

9

8

x10

7

6

5

4 3 2 1

0

9

8

x1

Side connecting terminal cover

(right & left 1 set)

DIN rail mounting 

end plate

DIN rail mounting 

end plate

Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome,

Shinagawa-ku, Tokyo 141-0032, Japan

http://www.fujielectric.com

Phone: 81-3-5435-7280, 7281   Fax: 81-3-5435-7425

http://www.fujielectric.com/products/instruments/

International Sales Div

Sales Group

Отзывы: