FRENIC-HVAC

 

Quick Reference Guide

Orange = Outputs

,

 Yellow = Analog Inputs

Blue = Digital Inputs

Control Card Terminals

FRENIC-HVAC Control Wiring

*1) To retain an alarm output signal ALM issued on inverter's programmable output terminals by the protective 

function or to keep the keypad alive even if the main power has shut down,

connect these terminals to the power supply lines. Even without power supply to these terminals, the inverter 

can run.

*2) Terminals [Y1] to [Y4] (transistor outputs) support both SINK and SOURCE modes.

*3) When the Enable function is not to be used, short-circuit terminals [EN1] and [PLC] and terminals [EN2] and 

[PLC] using jumper wires. For opening and closing the hardware circuit between terminals [EN1] and [PLC] and 

between [EN2] and [PLC], use safety components such as safety relays and safety switches. Be sure to use 

shielded wires exclusive to terminals [EN1] and [PLC] and terminals [EN2] and [PLC]. (Do not put them together 

with any other control signal wire in the same shielded core.)

*4) Usually there is no need to do anything regarding the EMC filter.

When the leakage current due to the built-in EMC filter causes problems with the power supply system, 

removing screws from terminals [E1] and [E2] may improve the problem.

Note that doing so the effect of the EMC filter is lost, and therefore the inverter is no longer compliant with the 

EMC standards. To remove those screws, consult your Fuji Electric representative.

*5) Normally there is no need to connect it. Must be connected if inverter is supplied from regenerative PWM 

converter (RHC Series) or from DC power supply.

EN2

Y5A

Y5C

Y3

Y4

V2

FM1

FM2

X5

X6

X7

X1

X2

X3

X4

EN1

30B

Y1

Y2

C1

11

30A

30C

CMY

11

12

DX -

13

CM

FWD

REV

PLC

SD

CM

DX +

• FWD, Rev, plus 7 Digital inputs.

Configurable for Source or Sink.

• 2 0-10VDC analog inputs.

• 4-20mA analog input.

• 4 Transistor outputs.

• 2 0-10V or 4-20mA analog outputs.

• Form A contact relay

o (250VAC 0.3A, cosØ=0.3), (48VDC, .5A).

• Form C contact relay

o (250VAC 0.3A, cosØ=0.3), (48VDC, .5A).

• 24VDC max 200mA DC output power.

• 10VDC output power for potentiometer.

• 2 Source only, safe torque off Enable Inputs.

• RS-485 wiring connections.

Other Control Terminal

• RJ-45 keypad connection port.

• USB Type B connection port when using USB keypad (TP-E1U).

• 3 Option card expansion ports.

Min.

Max.

Opera

ti

ng

Voltage

(Sink)

O

 level 

22V

27V

Opera

ti

ng

Voltage

(Sink)

O

 level 

0V

2V

Item

ON level

0V

2V

ON level

22V

27V

Max.

Opera

ti

ng

ON level

2V

Voltage

O

 level 

27V

50m A

Item

Maximum Current at on.

A. Run status indicator. 

B. Overload Warning Indicator.

C. Alarm indicator. 

D. Running direction.

E. Local Remote status monitor.

F. Main programmable Operation Monitor display.

G. Run/Stop Fault Status. 

H. 2 additional programmable Operation Monitor displays.

I. Date and Time display.

J. Program button.

K. Menu navigation arrow keys.

L. Alarm reset and previous screen key.

M. Set key for storing changes.

N. Remote and Local toggle and help button. 

O. Local mode control operators.

FRENIC-HVAC Multi-Function Keypad

M

Alarm relay output

(for any fault)

AX terminal

function

Data send/receive

RS-485 

communications 

port 2 (terminal 

block)

Analog

RS-485 communications port 1

(RJ-45 connector for

keypad connection)

During operation

Frequency (speed) agreement
Frequency (speed) detection
Motor overload early warning
Common terminal

(Shared between sink and source)

frequency meter

Analog

frequency meter

0V

+24VDC

0V

+10VDC

Setting voltage input

0~±10VDC

Setting voltage input

(0~+10VDC)

(0~±10VDC)

0~10VDC

3~

Setting current input

4~20mADC

(0~20mADC)

4~20mADC

(0~20mADC)

0~10VDC

4~20mADC

(0~20mADC)

Control power AUX input *1 

Fan power supply auxiliary input *5

Power supply

400V series

380V~480V

50/60Hz

Ground terminal

Main circuit

Ground terminal

Potentiometer

power supply

Magnetic contactor

(MC)

L1/R

L2/S

L3/T

13

12
11

1

3

2

R0

T0

R1

T1

G

E1

G

U

V

W

Enable input 1
Enable input 2

REV
CM

CM

X1
X2
X3
X4
X5
X6
X7

FWD

EN1

PTC

FWD operation/stop command

REV operation/stop command

Digital input common

Multi-step frequency selection (0~1steps)
Multi-step frequency selection (0~3steps)

Self-hold selection

Coast-to-stop command

Alarm reset

Frequency setting 2/frequency setting 1

Local (keypad) instruction selection

Digital input common

FM1

CMY

Y2

Y1

30C
30B
30A

Y5C
Y5A

30

Y3
Y4

FM2

11

SD

V2

C1

C1

SW5

EN2

PLC

SW1

SOURCE

SINK

SW4

SW6

SW3

SW2

*

7

MCCB

or ELCB

(+)

(-)

(+)

(-)

DX+

DX-

USB port

Motor

P(-)

 

P(+)

 

N(-)

Analog input

Digital input

Contact point output 

Control circuit

Transistor

output

*

4

*4

 

E2

*

3

*

2