 SAFETY FEATURES & CAUTIONS

 INTRINSICALLY SAFE APPROVAL

• ATEX
  EU-Type Examination Certificate: KEMA 07ATEX0136 X
    II 1G Ex ia IIC T4, T5, T6 Ga
  Zone 0
  EN 60079-0
  EN 60079-11
• IS Data
    Ui = 30V DC 

Uo = 6.4V DC

    Ii = 96mA DC 

Io = 30mA DC

    Pi = 720mW 

Po = 48mW

    Ci = 0 µF   

Co = 20 µF

    Li = 0 mH  

Lo = 10 mH

• Prior to installation, check that the safety class of this 

unit satisfies the system requirements.

• A safety barrier must be installed between the unit and 

its power supply.  Refer to “Installation Diagram” attached 
at the end of this manual when selecting a safety barrier.

• The power supply and the safety barrier must be located 

in a non-hazardous area.

• Environmental temperature must be within the following 

ranges depending upon the required temperature class.

    T4 : -40°C ≤ Ta ≤ +80°C
    T5 : -40°C ≤ Ta ≤ +65°C
    T6 : -40°C ≤ Ta ≤ +50°C
• DO NOT RUB the surface of the plastic enclosure with a 

dry cloth.  Electrostatic charge generated by the friction 
may cause an explosion.

• DO NOT APPLY physical impact or friction onto the 

FRC1 enclosure.

• Non-metallic materials (window cement) are contained in 

the FRC1/FRC2 enclosure and the user must consider the 
performance of these materials with respect to chemicals 
which may be present in the hazardous area.

• Be sure to secure the terminal cover after wiring (model 

FRC0).

• The wiring method must be in accordance with the electri-

cal parameters described in this manual.

• Be sure to earth the unit (model: FRC1/FRC2).
• The intrinsic safety approval of the model FRC1/FRC2 is 

applied to the combination of the outdoor enclosure and 
the transmitter.  The transmitter must not be separated 
or replaced.

• Substitution of components may impair suitability for the 

hazardous location and may cause an explosion.

• When metal particles are present in the air, install the 

model FRC0 inside an outdoor enclosure.

• For installing the FRC0 in an environment with a high 

relative humidity exceeding 0 to 95% RH or in a condens-
ing atmosphere, install the unit inside an outdoor enclo-
sure.

 Model FRC1/FRC2 FLAMEPROOF APPROVAL

• IECEx 
    Certificate of Conformity: IECEx CML 18.0140X
    Ex db IIC T4, T5, T6 Gb
  IEC 60079-0
  IEC 60079-1
• ATEX
  EU-Type Examination Certificate: CML 18ATEX1277X
    II 2G Ex db IIC T4, T5, T6 Gb
  Zone 1
  EN 60079-0
  EN 60079- 

1

• Threaded joint of cover: UN 3 

5

/

8

 - 12

• Engaged threads ≥ 8
• Prior to installation, check that the safety class of this 

unit satisfies the system requirements.

• Environmental temperature must be within the following 

ranges depending upon the required temperature class.

    T4 : -40°C ≤ Ta ≤ +80°C
    T5 : -40°C ≤ Ta ≤ +65°C
    T6 : -40°C ≤ Ta ≤ +50°C
• Use suitable heat resistant cable and cable glands for am-

bient temperatures ≥ 70°C

• Before wiring, make sure there is no danger of explosion 

in the atmosphere.

• Before opening the enclosure, wait at least for 60 seconds 

after the power is removed.

• The cable entry device and stopping plugs for unused ap-

ertures shall be of a certified flameproof type, suitable for 
the conditions of use and correctly installed. 

• The cable entry conduit is 1/2 NPT or M20 

×

 1.5 threaded.

• Six or more cable entry threads must be engaged.
• Squeeze the cable entry and stopping plug into the con-

duit with the proper tool.

• Before turning the power supply on, be sure to close the 

enclosure cover tightly and tighten the fastener as shown 
in Figure 1 using a hexagon key wrench.  When opening 
the enclosure, loosen the fastener first.

Tighten

Loosen

Fastener

Hexagon Key
Wrench

Figure 1. Enclosure fastener

• DO NOT RUB the surface of the plastic enclosure with a 

dry cloth.  Electrostatic charge generated by the friction 
may cause an explosion.

• Be sure to earth the unit.
• For external earthing or bonding connection a cable lug 

shall be used so that the conductor is secured against 
loosening and twisting and that contact pressure is main-
tained.

• The flameproof approval of this unit is applied to the com-

bination of the outdoor enclosure and the transmitter.  
The transmitter must not be separated or replaced.

• Substitution of components may impair suitability for the 

hazardous location and may cause an explosion.

Содержание FRC

Страница 1: ...1 Yes die cast aluminium 2 Yes stainless steel casting 2 SAFETY APPROVAL A None C IECEx ATEX flameproof for FRC1 FRC2 E ATEX intrinsically safe 3 LCD DISPLAY 0 None 1 LCD 4 WIRING CONDUIT 0 None for FRC0 1 1 2 NPT 2 M20 x 1 5 3 PG 13 5 WARNING Explosions could result in death or serious injury The enclosure cover must be fully engaged to meet flame proof requirements Do not remove the enclosure co...

Страница 2: ...RC0 in an environment with a high relative humidity exceeding 0 to 95 RH or in a condens ing atmosphere install the unit inside an outdoor enclo sure Model FRC1 FRC2 FLAMEPROOF APPROVAL IECEx Certificate of Conformity IECEx CML 18 0140X Ex db IIC T4 T5 T6 Gb IEC 60079 0 IEC 60079 1 ATEX EU Type Examination Certificate CML 18ATEX1277X II 2G Ex db IIC T4 T5 T6 Gb Zone 1 EN 60079 0 EN 60079 1 Threade...

Страница 3: ... to 4 Maximum Output Voltage Uo 6 4 V Maximum Output Current Io 30 mA Maximum Output Power Po 48 mW Maximum External Capacitance Co 20 μF Maximum External Inductance Lo 10 mH NOTES 1 2 In any safety barrier the output current of the barrier must be limited by a resistor R such that Io Uo R The safety barrier must be certified by an EU approved certification body to Ex ia IIC For Zone 1 and 2 Ex ib...

Страница 4: ...embly External Earthing Terminal Hazardous Location Zone 1 and 2 Non Hazardous Location PS PS 2 1 INSTALLATION DIAGRAM for IECEx ATEX FLAMEPROOF MODEL ELECTRICAL DATA Power Supply and Supply Voltage 12 to 28 V Output Current 4 to 20 mA Burnout Current 24 mA Sensor Circuit 1 to 4 Input Signal 1 0 V max NOTES 1 2 1 Install per local installation codes IECEx or ATEX approved cable entries or stopping...

Отзывы: