background image

3-1

Section 3  Installation

3-1  Mounting Procedure

(1) Mounting procedure

1) Insert the @E.Terminal unit into the mounting panel (max. thick: 5 mm).

X

Y

NP5M0101-5H4/NP5N0011-5H4

NP5M0101-3H4/NP5N0011-3H4

NP5M0101-4H4/NP5N0011-4H4

X

Y

313.0

289.0

220.5

X

246.2

216.2

165.5

Y

Panel cut-out dimensions

Types

Unit: mm

+0.5

-0

+0.5

-0

+0.5

-0

+0.5

-0

+0.5

-0

+0.5

-0

2) Insert four fixtures attached to the @E.Terminal unit into the mounting holes, and tighten them with the

tightening screws.
Tightening torque: 0.5 to 0.7 N·m

CN7

CN5

CF

LAN

U-B

U-A

RESET

CN1

MJ2

MJ1

4:RUN
3:U-TERM
2:TERM
1:STOP

ONL
ERR
UROM
RUN
ALM
BAT

DC24V

No.

USB

LOADER

USER RO

M CARD

0V

FG

CPU

SX-BUS

IN

OUT

17.8

10.5

Fixture dimensions
(Unit: mm)

18.0

* When the @E.Terminal unit is attached to the mounting panel, the fixtures and frame grounds (FG) are connected.

To prevent static electricity, be sure to connect the mounting panel to the frame ground.

3) Mount the gasket so that it will be sandwiched securely between the @E.Terminal unit and the mounting panel.

(2) Mounting angle
Install the unit within the angle of 15

°

 to 135

°

 as shown on the right.

0

°

135

°

90

°

15

°

Displa

y

Displa

y

Содержание @E.Terminal for MC

Страница 1: ...FEH300b Display Attached Controller E Terminal for MC USER S MANUAL Hardware...

Страница 2: ...in the MICREX SX series User s Manual Instruction Standard Loader MICREX SX series FEH588 Describes the memory language and system definitions of the MICREX SX series User s Manual SX Programmer Stand...

Страница 3: ...therwise electrical shock or damage may occur Never touch any terminals while the power is on Otherwise electric shock may occur You must put a cover on the terminals on the unit when you turn the pow...

Страница 4: ...e malfunction or damage to the unit Be sure to establish a ground of E Terminal The FG terminal must be used exclusively for the unit with the level of grounding resistance less than 100 Otherwise ele...

Страница 5: ...minal surface Use alcohol or benzine commercially available If a data receive error occurs when E Terminal and the counterpart PLC temperature controller etc are started at the same time read the manu...

Страница 6: ...contents Aug 2008 FEH300 First edition Nov 2008 FEH300a Display part is changed from UG40 series to V8 series Accessory Noise filter is eliminated from controller hardware version 03 or later Dec 200...

Страница 7: ...M0101 4H4 NP5N0011 4H4 2 9 2 2 3 External dimensions and panel cut out dimensions for the NP5M0101 3H4 NP5N0011 3H4 2 10 2 3 Names and Functions 2 11 2 3 1 Display unit 2 11 2 3 2 Controller unit 2 14...

Страница 8: ...Section 1 General Page 1 1 Overview of E Terminal for MC 1 1 1 2 Appearance 1 2 1 3 Types 1 3 1 4 System Composition 1 5...

Страница 9: ...LDIC and APLHA5 VS type minimizing the need for wires 3 The upper level controller can be connected by Ethernet and the like 4 The lineup includes three different display screen sizes 8 inch 10 inch a...

Страница 10: ...tached with screws to the connector area of the communication unit at the back of the display unit similar to the way in which the communication unit is attached U A U B LAN CN1 MJ2 MJ1 CF CN5 CN7 4 R...

Страница 11: ...0011 5H4 4H4 2 M3 x 8 screw for USB cable cramp Only NP5M0101 5H4 4H4 NP5N0011 5H4 4H4 2 Noise filter Note2 1 Note 1 Backup CD is not attached to NP5N0011 5H4 4H4 3H4 Note 2 Noise filter is not attach...

Страница 12: ...BT Primary lithium battery for memory data backup for controller unit SX bus terminating plug NP8B BP For SX bus loop terminating 1 piece SX bus expansion cabl NP1C P3 Cable length 300mm NP1C P6 Cabl...

Страница 13: ...5 FALDIC FALDIC ALPHA5 FALDIC V CP Up to 8 servos and I O terminals each can be connected SX bus station No 221 SX bus station No 228 I O terminal Input 8 points Output 8 points NR1SW 16T65DT I O term...

Страница 14: ...6 1 Application performance specifications 2 6 2 Specific system memory 2 7 2 2 Dimensions and Panel Cut out 2 8 2 2 1 External dimensions and panel cut out dimensions for the NP5M0101 5H4 NP5N0011 5H...

Страница 15: ...rated 42 W or less 37 W or less 35 W or less Rush current 170 A or less Input terminal block Display unit Terminal block screw M3 5 Connection to the controller unit Tightening torque 0 8 N m Control...

Страница 16: ...cklight only Approx 50 000 hours at the normal temperature of 25 C Backlight auto OFF function Always ON random setting Brightness adjustment Function switch 3 levels Macro 128 levels Surface sheet ma...

Страница 17: ...dards Compliant with IEEE802 3u 100BASE TX IEEE802 3 10BASE T Baud rate 100 Mbps 10 Mbps Recommended cable 100 UTP unshielded twist pair cable category 5 max 100 m long Applications PLC connection etc...

Страница 18: ...32 x 32 dots Enlargement factor X 1 to 8 times Y 1 to 8 times Point Note 2 8 9 10 11 12 14 16 18 20 22 24 26 28 36 48 72 Number of displayable characters Display resolution 800 x 600 1 4 size 100 cha...

Страница 19: ...ers 1 byte No limitation Sampling Sampling display of buffer data Constant sampling bit synchronization alarm logging time order alarming alarm function Graphic library Max 2560 Overlap library Max 10...

Страница 20: ...48 words 8192 words System memory 512 words No of tasks Default tasks Cyclic scanning 1 Periodic tasks 4 Event tasks 4 Total of 4 tasks when periodic task is used No of programs Max 256 Max 128 for on...

Страница 21: ...s Names Descriptions SM1240 MX10 124 0 Display unit connection status flag Represents whether a display unit is connected ON OFF of display unit power supply 1 Connected 0 None Cause of memory error A...

Страница 22: ...al dimensions and panel cut out dimensions for the NP5M0101 5H4 NP5N0011 5H4 Unit mm CN5 313 0 0 5 0 246 2 0 5 0 326 4 259 6 99 0 66 7 0 312 0 245 2 312 0 99 0 F 7 F 6 F 5 F 4 F 3 F 2 F 1 SYSTEM 4 RUN...

Страница 23: ...al dimensions and panel cut out dimensions for the NP5M0101 4H4 NP5N0011 4H4 Unit mm F 1 F 2 F 3 F 4 F 5 F 6 F 7 SYSTEM CN5 CN7 289 0 0 5 0 216 2 0 5 0 231 0 303 8 215 2 288 0 99 0 7 0 99 0 288 0 U A...

Страница 24: ...0 233 0 178 0 6 9 96 0 LAN U B U A CN7 CF MJ1 MJ2 4 RUN 3 U TERM 2 TERM 1 STOP ONL ERR UROM RUN ALM BAT No USB LOADER USER ROM CARD CPU SX BUS IN OUT Front view Rear view Side view Panel cut out dime...

Страница 25: ...P5N0011 5H4 1 2 3 4 17 15 14 13 12 11 10 9 5 7 8 16 6 CN5 CN7 CF U B U A LAN CN1 MJ2 MJ1 F 7 F 6 F 5 F 4 F 3 F 2 F 1 SYSTEM 2 NP5M0101 4H4 NP5N0011 4H4 9 10 11 12 13 14 15 F 1 F 2 F 3 F 4 F 5 F 6 F 7...

Страница 26: ...unit Hidden by the controller unit 5 Optional unit connector CN7 Used for mounting the optional unit GU xx for video input sound output RGB input or RGB output 6 Battery holder Contains a backup batte...

Страница 27: ...e controller inverter etc 13 100BASE TX 10BASE T connector LAN Used for Ethernet connection 14 USB B slave port Used for screen data transfer or connection with a PictBridge compatible printer 15 USB...

Страница 28: ...4V DC FG 4 Data backup battery 2 Key switch 3 CPU No selection key switch 9 USB miniB connector 8 Loader connector 7 Connector for user ROM card CF card 6 Power supply terminal block 3 poles Version N...

Страница 29: ...essing the user ROM BAT Orange Turned on when data backup battery dropped or disconnected Note The system includes the own CPU 2 Key switch Controller unit Selects the running mode of the controller u...

Страница 30: ...end 8 CTS Clear to send NC Not used 9 NC Not used 5V Use prohibited Note 2 Note 1 The signal level can be changed between RS 232C and RS 422 485 on the configuration software When RS 232C is selected...

Страница 31: ...l Contents 1 SD RD RS 485 data 2 SD RD RS 485 data 3 5V Externally supplied 5 V Note 1 4 5V 5 SG Signal ground 6 SG 7 RD RS 232C receive data 8 SD RS 232C send data Note 1 Allowable current for the ex...

Страница 32: ...J1 modular jack 1 terminating resistor CN1 SD SD terminating resistor at pins 3 and 4 Dip switch number 1 Note CF Auto uploading Set the dip switch number 1 to the ON position when auto uploading a sc...

Страница 33: ...5 and 7 to the OFF position When connecting a controller at CN1 via RS 422 485 2 wire connection set the dip switch number 7 to the ON position When connecting a controller at CN1 via RS 422 485 4 wi...

Страница 34: ...Section 3 Installation Page 3 1 Mounting Procedure 3 1 1 Mounting procedure 3 1 2 Mounting angle 3 1 3 2 Power Supply Cable Wiring 3 2 1 Power supply cable wiring 3 2 2 Grounding 3 4...

Страница 35: ...rews Tightening torque 0 5 to 0 7 N m CN7 CN5 CF LAN U B U A RESET CN1 MJ2 MJ1 4 RUN 3 U TERM 2 TERM 1 STOP ONL ERR UROM RUN ALM BAT DC24V No USB LOADER USER ROM CARD 0V FG CPU SX BUS IN OUT 17 8 10 5...

Страница 36: ...ADER USER ROM CARD CPU SX BUS IN OUT 24V DC FG Power supply Grounding 24V DC FG Power supply Grounding 24V DC FG Attaching noise filter Attach accompanying noise filter to the power supply cable betwe...

Страница 37: ...aker Form Types Cable size AWG mm2 AMP Round terminals 36467 22 to 18 0 3 to 0 8 mm2 34104 34105 Nichifu Round terminals 0 3 3 24 to 20 0 2 to 0 5 mm2 0 3 3N 1 25 3 22 to 16 0 3 to 1 3 mm2 1 25 3N 1 2...

Страница 38: ...l cross section of more than 2 mm2 for grounding Set the grounding point near the E Terminal to shorten the distance of grounding cables Other equipment E Terminal Other equipment E Terminal Other equ...

Страница 39: ...pection 4 1 4 1 2 Periodical inspection 4 1 4 2 Battery Replacement 4 2 1 Battery specification 4 2 2 Precautions 4 2 3 How to replacement battery 4 2 4 3 Maintenance Services 4 4 4 3 1 Ordering notes...

Страница 40: ...ber of inspections may be increased as necessary if facilities are relocated or modified or the environment is hot humid or dusty 4 1 2 Periodical inspection Inspect the following points periodically...

Страница 41: ...Battery boltage drop detection funnction Provided Internal memory of s167 allocated Battery for replacement Type V7 BT Required time in the battery replacement 3 minutes or less 2 Precautions Do not s...

Страница 42: ...left illustration below RESET U A U B LAN CN1 MJ2 MJ1 CF CN5 CN7 3 Remove battery connector and slide battery to remove it from its socket as shown in the right figure 4 Insert a new battery into the...

Страница 43: ...or different voltage applied due to wiring mistake power supply terminal external communication terminal or other terminal blocks Failure caused by lightning surge Failure due to the entry of conduct...

Страница 44: ...Appendix 1 About Project for E Terminal No contents installed Page Appendix 1 About Project for E Terminal No contents installed App 1 1...

Страница 45: ...2 Template file The file for SX programmer Expert SPH2000 48CR zwt The file is compressed project type Uncompress the project before use The file for SX programmer Standard SPH2000 48CR Sxt The file...

Страница 46: ...te City Ohsaki East Tower 11 2 Osaki 1 chome Shinagawa ku Tokyo 141 0032 Japan Phone 81 3 5435 7280 Fax 81 3 5435 7425 URL http www fesys co jp eng Printed in Japan 2008 12 FIS Printed on recycled pap...

Отзывы: