3a. 

WARNING!

  Vehicle’s fuel system may be under pressure!  

DO NOT

 loosen any fuel connections until relieving all fuel 

system pressure.  Consult an applicable service manual 
for instructions to relieve fuel system pressure safely.  
Remove 

ALL

 Fuel and Fuel Vapors from the fuel tank, to 

allow a safe fabrication of the Fuel Tank.  

GASOLINE 

AND OTHER FUELS ARE FLAMMABLE AND CAN BE 
EXPLOSIVE!

  This step 

CANNOT

 be overlooked or 

ignored.  While in many cases, it may be safe to perform 
fabrication while the Fuel Tank remains installed in the 
vehicle, it may be recommended to remove the Fuel Tank 
from the vehicle prior to proceeding. 

3b.  Refer to the requirements shown in figures on this sheet 

and the next, regarding tank requirements.  These include: 

Flat top with an accessible area at 4.70” diameter.
This area 

MUST HAVE

 a good surface finish to seal

the flange against the tank using the supplied gasket.
This flat area can be at an angle or even side of tank if
required.  

DO NOT INSTALL ON THE BOTTOM OF

THE TANK!!

Minimum Depth (reference figures) is 8-3/4”.

Maximum Depth (reference figures) is 15-5/8”.

4.70 MINIMUM

TANK FLANGE SIZE

REQUIREMENT

(NOT INCLUDED) 

10X HARDWARE

NOT SHOWN:
TANK VENT

5.50 RECOMMENDED

MINIMUM TANK WIDTH

A

A

SECTION B-B

MAXIMUM INSTALLATION HEIGHT

SHOWN ABOVE

15.63 MAXIMUM

TANK DEPTH

10X  .20 THRU

EVENLY SPACED

 3.31 

THRU 

4.00

CENTERLINE
FOR SCREWS

B

B

SECTION A-A

MINIMUM INSTALLATION HEIGHT

SHOWN ABOVE

FUEL PUMP

8.75 MINIMUM

TANK DEPTH

TANK MUST BE VENTED!

DO NOT ALLOW A

VACUUM TO FORM

INSIDE TANK!

110021251-1, Rev B        Sheet 4 of 8

Содержание 93901

Страница 1: ...our Fuelab distributor immediately for replacement 93901 Features and Performance Ratings Inlet Port Size 8AN Military Port Outlet Port Size 8AN Military Port Fuel Cell Ports 3x 8AN Military Ports Rated Flow Rate 66 GPH 45 PSI 13 5V 250 LPH 3 Bar Maximum Pressure 125 PSI 8 5 Bar Operating Voltage 8 18 Volts Maximum Current Draw 15 Amperes WARNING Power Supply Voltage must be constant as specified ...

Страница 2: ... may serve as return fill or vent ports according to fabricator installer discretion Use 8AN plugs on all unused auxiliary ports 8AN fuel compatible o rings are supplied with the fuel pump that are to be used with all five 5 8AN fuel ports Use of a liquid filled gauge exposed to engine compartment heat is not recommended as the liquid inside the gauge may exert measurement errors DO NOT plumb to a...

Страница 3: ... maximum speed or flow setting Electronic devices such as Engine Management Units may have an output that can produce PWM Signals compatible with this Controller Attach this white signal wire to ground to operate system in Full Speed Mode not using speed control MAIN WIRING SCHEMATIC DIAGRAM Some electrical components shown are not supplied with kit Installation Steps 1 Disconnect the ground termi...

Страница 4: ...on this sheet and the next regarding tank requirements These include Flat top with an accessible area at 4 70 diameter This area MUST HAVE a good surface finish to seal the flange against the tank using the supplied gasket This flat area can be at an angle or even side of tank if required DO NOT INSTALL ON THE BOTTOM OF THE TANK Minimum Depth reference figures is 8 3 4 Maximum Depth reference figu...

Страница 5: ...ting in Step 3f herein Write down this new value here for convenience ________________ INCHES 3f Using the calculated value from Step 3e second value obtained after subtraction measure and mark the Pick Up Tube Assembly as shown above right Use a Pipe Cutting Tool to cut the tube at the marked position to achieve the correct installation length for the Pick Up Tube Assembly as measured in Step 3e ...

Страница 6: ... repeat priming procedure to ensure that fuel pump is receiving fuel from tank Turn on fuel pump typically by bypassing fuel pump relay without engine operating ECU or engine management computer may be controlling the relay The ECU may only operate pump for a few seconds each time ignition switch is set to on The pump will have to operate several seconds 30 to prime and drive air out of the fuel s...

Страница 7: ...improperly sized wire Debris from tank or plumbing lodged inside pump Check voltage to controller at power terminals If voltage is steady and consistent within 1 2 Volt of battery then contact Fuelab for assistance or repair If voltage is inconsistent as described repair or replace electrical components as required Not building up fuel pressure Incorrect fuel system initial priming procedure Pump ...

Страница 8: ...ive obligation of Manufacturer shall at its option be to repair or replace the defective Products in the manner and for the period provided above or to refund the purchase price Manufacturer shall not have any other obligation with respect to the Products or any part thereof whether based on contract tort strict liability or otherwise 4 Other Statements ORAL OR OTHER WRITTEN STATEMENTS BY MANUFACT...