FuehlerSysteme eNET International Compact FS6003 Скачать руководство пользователя страница 29

 

29 / 34 

ba_7-1-120/11E/0318

 

 

7  LED signals 

On the underside of the COMPACT FS6003 Weather Station there are 2 LEDs which are externally 
visible through the housing. 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 1 : LEDs 

 

If the Weather Station does not receive a command to query measured values for 3 seconds or 
longer, the green LED flashes at a frequency of 1Hz and signals its readiness for operation. If 
automatic telegram output is enabled (see 

Command TT

), the green LED remains dark. 

The flash frequency of the blue LED indicates the current wind speed (see 

Command LC

). The 

correlation between the flash frequency and wind speed is shown in the following figure: 

 

 

 

 

0

5

10

15

20

25

30

35

40

0

5

10

15

20

25

30

35

40

Fr

e

q

u

e

n

c

y

 [

H

z

]

WV [m/s]

Flash frequency of blue LED as a function of wind velocity

f = 0,9759*WG + 

 

 

 

green LED 

blue LED 

 

Содержание Compact FS6003

Страница 1: ...1 34 ba_7 1 120 11E 0318 Instructions for Use Weather Station Compact FS6003...

Страница 2: ...oduct is designed for a specific application as described in these operating instructions The device product should be operated with the accessories and consumables supplied and or recommended by the...

Страница 3: ...g cable 12 5 Maintenance 13 6 Interface 14 6 1 Command interpreter MODBUS RTU 14 6 1 1 Measuring values Input Register 15 6 1 2 Commands Holding Register 19 6 2 Commands and description 20 6 2 1 Comma...

Страница 4: ...characteristics of brightness sensors 32 Figure 4 Spectrum for global irradiance sensor 33 Instructions for use These instructions for use describe all application and adjustment options for the devic...

Страница 5: ...e following measured variables Wind speed Wind direction 4 x brightness north east south west Twilight Global irradiance Precipitation Air temperature Absolute air pressure Relative air pressure Time...

Страница 6: ...icium photo sensors which are aligned to the 4 cardinal directions in the mean elevation angle 40 Twilight Twilight means the light diffusion in the atmosphere which arises with the smooth transition...

Страница 7: ...80665m s2 R 287 05287m2 K s2 Tb 288 15K The station height required for the calculation can be entered manually by the Command SH or can be determined automatically by GPS If you want to achieve an ac...

Страница 8: ...FS6003 the first satellite data are available after approx 2 5min When receiving the signals from one satellite time with an accuracy of 1 s When receiving the signals from three satellites position...

Страница 9: ...ench Procedure 1 Push cable plug connection through the bore hole of the mast tube bracket etc 2 Put FS6003 on mast tube 3 Align FS6003 to north Procedure see chapter 4 2 1 4 Secure FS6003 by the M4 h...

Страница 10: ...ss 2 Via the north marking N and an imaginary north south axis the weather station is to be located on the prominent object 3 Align weather station The north marking must indicate to the geographic no...

Страница 11: ...cope of supply 4 3 1 Cable cable preparation connector installation The cable to be used for connection should have the following properties 5 cores core cross section max 0 14mm cable diameter max 5...

Страница 12: ...pply voltage GND 4 3 3 Connection using cable PIN Core colour Function 1 WHITE NC 2 BROWN DATA _ GND 3 GREEN DATA 4 YELLOW DATA 5 GREY NC 6 power 18 30V DC 18 28V AC 7 power 18 30V DC 18 28V AC With l...

Страница 13: ...required Depending on the location the instrument might pollute The cleaning should be carried out by means of water and a soft cloth Aggressive cleaning agents must not be used Please note During sto...

Страница 14: ...is selected the transmitted bytes are interpreted according to the MODBUS specification http www modbus org Here the weather station FS6003 is representing a MODBUS Slave The data transmission is carr...

Страница 15: ...01 to 39999 Register address Parameter Name Unit Multiplicator Explanation Data type 30001 Wind speed m s 10 value 10 1 decimal place e g 101 10 1m s U32 30003 Mean value Wind speed m s 10 value 10 1...

Страница 16: ...us 1 value no decimal place 0 no precipitation 1 precipitation U32 34601 Date 1 value no decimal place JJJJMMTT e g 20121210 10 12 2012 U32 34603 Time 1 value no decimal place HHMMSS e g 121035 12 10...

Страница 17: ...cimal place e g 115 11 5 C S32 35015 Rel humidity 30601 1 r h 10 value 10 1 decimal place e g 355 35 5 r h U32 35017 Abs humidity 30603 1 g m 3 100 value 100 2 decimal places e g 923 9 23g m 3 U32 350...

Страница 18: ...clockwise 0 360 S32 35051 Height above sea level 34809 1 m 1 Wert no decimal place e g 240 240m above sea level U32 35053 Sensor status 34811 1 1 value no decimal place bit coded dep of sensor U32 35...

Страница 19: ...nting unsigned integral numbers The following example shows the changing of the baud rate to 19200baud 1 Set password for the user level KY 234 Slave address Function code Starting address Number Regi...

Страница 20: ...nd RS 40029 Reset None User Command SH 0 40071 Station height None User Command SV 45005 SW Version None Command TR Telegram output None None Command TT 0 Automatic telegram output None None Command T...

Страница 21: ...21 34 ba_7 1 120 11E 0318 Initial value 10...

Страница 22: ...t Access Read write Description The mode of calculation for twilight is stated by command DC The twilight is calculated from the 4 brightness values depending on direction Here one can select between...

Страница 23: ...mmand FB id FB parameter CR Quick start mode Access Read write Description The command FB is used to select quick start mode Parameter description 0 quick start mode disabled 1 quick start mode enable...

Страница 24: ...dentification number INTERNER BUS interpreter resp the slave address MODBUS RTU Interpreter A response telegram will only be transmitted if the id in the command matches the one set in the Weather Sta...

Страница 25: ...er CR Reset Access Read write Description Through the command RS a reset of the microcontroller is carried out The cause for the last reset is output without stating a parameter Here the output occurs...

Страница 26: ...lation of the relative air pressure is based on the height from the GPS data Value range 0 3001 Initial value 0 Remark GPS determines ellipsoidal heights above the reference ellipsoid World Geodetic S...

Страница 27: ...ue 6 2 14 Command TT id TT parameter CR Automatic telegram output Access Read write Description The command TT is used to select the automatic output of telegrams interval 1 second Automatic telegram...

Страница 28: ...ed to change the output of date time Parameter description 0 UTC 23 UTC Zeit 1 hours 24 UTC Zeit 25 UTC Zeit 1 hours 48 CEST or CET The change between summer and winter time occurs independently TZ Si...

Страница 29: ...flashes at a frequency of 1Hz and signals its readiness for operation If automatic telegram output is enabled see Command TT the green LED remains dark The flash frequency of the blue LED indicates th...

Страница 30: ...ution 0 1kLux Accuracy 3 4 5kLux Spectral range 475 650nm Twilight Type Silicon sensor Measuring range 0 999Lux Resolution 1Lux Accuracy 10Lux Global irradiance Type Silicon sensor Measuring range 0 1...

Страница 31: ...housing Type Silicon sensor Measuring range 30 60 C Resolution 0 1 C Accuracy 2 C Digital interface Type RS485 Mode Half duplex mode Baud rate 1200 2400 4800 9600 19200 38400 57600 115200 Data format...

Страница 32: ..._7 1 120 11E 0318 Figure 2 Spectrum of brightness sensors Source data sheet for component SFH5711 OSRAM Figure 3 Directional characteristics of brightness sensors Source data sheet for component SFH57...

Страница 33: ...34 ba_7 1 120 11E 0318 Figure 4 Spectrum for global irradiance sensor Source data sheet for component TEMD5080X01 VISHAY 9 Dimension drawing in mm Srew M4 Allen key size 2 mm Plug connection Mast hold...

Страница 34: ...MPACT FS6003 Weather Station to a vertical surface Length 250mm Width 60mm Material Stainless steel 1 4301 Copyright FuehlerSysteme eNET International GmbH Address FuehlerSysteme eNET International Gm...

Отзывы: