5. MODE SETTINGS
BODY/AMBIENT setting
This IR thermometer has 2 measuring modes: Surface Temperature and Body
Temperature. It may arrive in the Surface mode. In order to use it for body temperature,
switch to Body mode.
Turn the unit on. Press button (the bottom center button with the icons of a head
and a house) to switch between BODY and SURFACE TEMP (ambient) measuring modes.
Fahrenheit or Celsius temperature setting
Turn the unit on. To switch between Fahrenheit and Celsius, press (Set) button
once. The unit does not speak or beep during this change. The temperature setting (C
or F) is displayed in the upper right hand corner of the display screen.
Voice Toggle On or Off
Turn the unit on. To turn the voice on and off, press and hold (Set) button for 5
seconds till “ON” displays. Press SET button again to toggle between ON and OFF.
This will turn the voice on and off. The voice status is shown by the alarm icon in the
bottom right corner of the display screen.
Change Between English or Spanish
Turn the unit on. Press and hold (Set) button for 8 seconds. The unit will display
ON (or OFF) for the Voice setting, but continue to hold Set. After 8 seconds, unit will
display 01 or 02. Press (Set) again to toggle between 01 for English and 02 for
Spanish. (Voices 03 through 06 are not active.)
Back light, laser selection
Press (light bulb/sunshine) button to toggle between the following functions in this
order: back light on, laser on, back light off, laser off. When you see (triangle) on
the LCD, it means the laser will be on once you use the device . When the backlight or
laser setting is enabled, it will come on every time the unit is turned on.
Memory recall
With the unit on, press (Memory) button to view recent measurements. Each push
of M will scroll through recent measurements. Memory results are only visual and are
not spoken. The memory capacity is 32 results
。
6. Measuring
Install 2 AA batteries (not included.)
Push and slide the blue battery cover forward to open the battery compartment.
Insert 2 batteries. The positive end is closest to the cover hinge; the negative end is
furthest away from the hinge.
After inserting new batteries, wait 10 minutes for the unit to warm up.
Turn on the unit by squeezing the blue scan button on the front of the handle. The unit
will take a measurement as soon as it is turned on
If the mode is “BODY” last time you used, the LCD will display “Lo”; if the mode is
“SURFACE TEMP” last time you used, the LCD will show the ambient room temperature
Make sure the temperature mode is set to BODY when taking a body temperature
If the device is not used for a long time, when you turn on it again the device will check
the room temperature first and delay tuning on for 1~2 seconds.