Table 2-2: Data Log Directory and Naming Structure
:
DATA LOG TYPE DIRECTORY AND NAMING STRUCTURE
.csv
Directory:
/LT1-CELL<serial number>/DATA/<filename>
/LT1-GOES<serial number>/DATA/<filename>
/LT1-IRID<serial number>/DATA/<filename>
Naming structure:
(8_dig_serial_number)_(8_dig_sequence_number)_(compact_timestamp)_DATA.csv
Raw telemetry
Directory:
/LT1-CELL<serial number>/TELEM/<filename>
/LT1-GOES<serial number>/TELEM/<filename>/
LT1-IRID<serial number>/TELEM/<filename>
Naming structure:
(8_dig_serial_number)_(8_dig_sequence_number)_(compact_timestamp)_TELEM.txt
Naming structure example Telemetry log:
00000019_00000160_20180218T062746Z_Telem.txt
This is the Telemetry data file for SN 19, sequence number 160, starting on Feb 2, 2018 at
6:27:46 UTC
2.3.3
COPYING DATA FROM THE SD CARD
1)
To copy data from the SD card, the card must be safely removed from the LT1 in one of two
ways:
a)
Connect to the LT1 with the FTS360 Config App using Bluetooth. From the Station
Dashboard select the SD Card menu and then the “Safely remove SD card” button. Follow
the prompts; or
b)
Power down the LT1 by removing the power terminal block.
IMPORTANT!
Failure to safely remove the
SD card can result in corrupted data.
2)
Insert the SD card into a device (such as a laptop) which has an SD card reader;
5
Firmware version 1.4 and later
Sequence
#
Date
yyyymmd
Time
HHmmssUT
LT1 Serial
#
Data log
type