5.2 Charging Operation
1) Connect the charger to electric vehicle
1.
Plug the charging connector into the EV charger.
2.
After plug-in, please check the connector is connected correctly and tightly.
3.
When the connection is correctly established, the charger’s LED indicator will be a flashing yellow
light, which indicates that the charger is ready for charging.
2) Start charging & stop charging
1.
By RFID card: Using the RFID card to identify on LCD screen.
2.
Plug & Play mode : After plug in connector, will begin charging , and will stop charging after plug
out connector from car side.
3.
By APP: Click ‘Start’ will begin charging, click ‘Stop’ will stop charging.
6 Troubleshooting
6.1 Indicator Status
State
Description
LED Status
In standby
Normal
Flashing green, 1S on, 4S off
Charging status
Normal
Breathing green, 1S on, 1S off
Plugged gun state
Normal
Breathing yellow, 1S on, 1S off
Software upgrade
Normal
Green light flash
Ground warning
Normal
Flashing yellow, 2S on, 2S off
Relay adhesion
Fault
Red light normally on
Input polarity reverse
Fault
Flashing red, 500ms on, 500ms off, 1 time, 3S off, Cycle
CP fault
Fault
Flashing red, 500ms on, 500ms off, 2 times, 3S off, Cycle
Leakage current fault
Fault
Flashing red, 500ms on, 500ms off, 3 times, 3S off, Cycle
Input terminal over
temperature
Fault
Flashing red, 500ms on, 500ms off, 4 times, 3S off, Cycle
Relay overtemperature
Fault
Flashing red, 500ms on, 500ms off, 5 times, 3S off, Cycle
Under voltage fault
Fault
Flashing red, 500ms on, 500ms off, 6 times, 3S off, Cycle
Over voltage fault
Fault
Flashing red, 500ms on, 500ms off, 7 times, 3S off, Cycle
Overload fault
Fault
Flashing red, 500ms on, 500ms off, 8 times, 3S off, Cycle
Over frequency fault
Fault
Flashing red, 500ms on, 500ms off, 9 times, 3S off, Cycle
Owe frequency fault
Fault
Flashing red, 500ms on, 500ms off, 10 times, 3S off,
Cycle
Leakage current loop abnormal
Fault
Flashing red, 500ms on, 500ms off, 11 times, 3S off,
Cycle
Содержание UNIVERS U+ WB1-11-OCPP-LK7
Страница 1: ...U WB1 7 OCPP LK7 U WB1 11 OCPP LK7 MANUAL DEL USUARIO USER S MANUAL MANUEL D UTILISATION ...
Страница 2: ......
Страница 3: ...U WB1 7 OCPP LK7 U WB1 11 OCPP LK7 ESPAÑOL MANUAL DEL USUARIO ...
Страница 4: ......
Страница 15: ...U WB1 7 OCPP LK7 U WB1 11 OCPP LK7 ENGLISH USER S MANUAL ...
Страница 16: ......
Страница 27: ...U WB1 7 OCPP LK7 U WB1 11 OCPP LK7 FRANÇAIS MANUEL D UTILISATION ...
Страница 28: ......
Страница 39: ......