FTE Maximal TSQ 310 CI Скачать руководство пользователя страница 16

User’s manual · TSQ 310 CI 

 

         

- 14 -                TSQ  310 CI                version_en_1.0              FTE maximal 

 

2. Auto  
This option allows saving and loading the configuration of the module in the PRO 
201 programmer.  
 
 
 
 
- Read from module: It stores the current configuration of the module in the memory of the programmer. The steps to 
make a correct reading of the headend are specified below: 
 

 

 

 

 

1. Select the option “Read from 
module” through Up/Down buttons. 
Press OK to continue  

2.  Select the position of “CFG” 
memory where you wish to save the 
current configuration of the module. 

3. A window will appear and it will let 
you know that the reading made has 
been correct 

 
 
- Write to module: It loads in the module one of the configurations previously saved in the memory of the programmer. The 
steps to make a correct configuration of the headend are specified below: 
 

 

 

 

 

1. Select the option “Write to module” 
through Up/Down buttons. Press OK 
to continue  

2.  Select the position of the “CFG” 
memory that you wish to copy in the 
module. Please verify that the data of 
the selected memory correspond to 
the channel that you wish to copy. 

3. A window will appear and it will let 
you know that the configuration made 
has been correct 

 
 
3. Config  
In “Config” option the information concerning the transmodulator is given.  
 
- Read log: It allows reading the registered events in the module.  

 

 

 

 

 

1. Select the option “Read LOG file” 
through Up/Down buttons. Press OK 
to continue  

2.  Press OK again to show the log file.  3.  A  new  window  will  appear.  It  will 

show the information about the 
registered events in the module. Press 
the following keys in order to scroll up 
and down the screen: “up/down”. 

 
- Delete LOG file: It allows deleting all events stored until this moment.  
- Factory default: This option restores the values by default of the transmodulator.  
- Update FW: It allows carrying out the firmware update from the programmer.  
- Output services: This option allows making the selection of the services that you wish to include in the output multiplex.  
Once you have tuned a transponder and you have selected the DVB-T/DVB-H modulator configuration, you can make the 
assignment of the services that are going to be included in the output multiplex “Adding/Removing services”.  

 TSQ310CI 
N:00001    Status:03 
07/02/11   09:05:02 
Front-end lock

 

  TSQ310CI 
 
OK to Show LOG 

  TSQ310CI 
 LCN 
>Read LOG file 
 Delete LOG file 

TSQ310CI 

 
Operation finish

 

TSQ310CI 

                CFG:01 
Freq:11362    Sr:27500 
Output     Freq:850000

 

TSQ310CI 
 
> *Write to Module * 
  *Read from Module*

  TSQ310CI 
 
Operation finish

 

  TSQ310CI 
              CFG:03 
 
Free position

 

  TSQ310CI 

 

> *Read from Module* 
  *Write to Module *

 TSQ310CI 

 

> *Read from Module* 
  *Write to Module * 

 TSQ310CI 
 LCN 
>Read LOG file 
 Delete LOG file 

Содержание TSQ 310 CI

Страница 1: ...TSQ 310 CI USER S MANUAL ...

Страница 2: ......

Страница 3: ...nges of temperature 8 Never open the device by yourself due to electric risk In case of problems go always to qualified technicians 9 Never under no circumstances open the device when connected to the electrical net 10 During the handling it is better to disconnect the device from the electrical net 11 Obey the electricity security rules during the assembling Use materials that obey the current la...

Страница 4: ...e MIX connector 4 MIX Input of mixing of the module 5 LNC IN To connect to the LNC or to the LOOP OUT output of the previous module 6 LOOP OUT To connect to the ANT IN input of the next module 7 RS 232 Ethernet connector to cascade modules with the RCM 310 telecontrol unit with the RJ45 RJ45 cable provided 8 PRO 201 Ethernet connector to make the programming with the programmer 9 DC connectors It ...

Страница 5: ...ls and output parameters 1 4 Programming TSQ 310 has two ethernet connectors In order to make the programming of the module you have to connect the corresponding programmer to PRO 201 connector You can make the programming through the PRO 201 programmer and also through the mediaMAX EVO and mediaMAX MINI field strength meter 1 4 1 Programming modes With mediaMAX EVO mediaMAX MINI field strength me...

Страница 6: ...option through the key 8 of your field strength meter and to select the Prog Transmodulators option Then it will proceed to recognize the module and to show the main menu In the Prog Transmodulators are shown the different configuration options that this tool offers 1 Module selection The field strength meter allows carrying out the programming of one or several transmodulators from an only transm...

Страница 7: ...llator Selection of the local oscillator that you wish to use FI KU C K9750 K10000 K10600 K10700 K10750 K11250 K11300 K11325 Frequency MHz Transponder frequency that you wish to tune Symbol speed Symbol speed required by the transponder Auto symbol rate You will be able to select if the detection of the Symbol Rate is going to be Automatic On or Manual Off In Manual mode Off the value of the Symbo...

Страница 8: ...ering the bigger this value is the less interference between symbols that will be caused Typical Value according to rules DVB C 15 Options 15 13 5 Output configuration In this option you can configure the different parameters of the cable signal Channel standard It allows you to select the channelling of the cable signal standards Options BG BG PAL BG IT 11 M NTSC PAL M PAL N PAL DK PAL I BB_AU DK...

Страница 9: ...em information It allows you to visualize the basic information of the module model no of series firmware version etc Settings This option allows saving and loading the configuration of the module carrying out firmware update or making an adjustment of the time and date of the module Clock Set Date and time Setting of the date and time of transmodulator It is appropriate to maintain these paramete...

Страница 10: ...ree different options Auto The Meter decides where the data will be stored If there is external memory connected the Meter will store the data in it If not it will use the internal memory USB The Meter always will try to use the external memory connected to the USB port If this memory has not been connected an error message will be shown reminding that there was an error storing the data and it wi...

Страница 11: ...iplex Note It is not recommended to exceed the 85 of the maximum capacity of the multiplex due to the possible variability of the bits rate of the inputs services Recomendad capacity lower to 85 Excessive capacity It is recommended to remove services Removing services 1 Select the Service to remove option 2 Select one of the transponder services you want to remove 3 Once you have chosen the servic...

Страница 12: ...The receiver will have this state by default Always It selects the services automatically every time a new input carrier is tuned This state is only recommended to be used for making test in the module Off The automatic mode is deactivated the services have to be manually selected Advanced settings Network It allows making the adjustment of the identification parameters of the multiplex TS ID Tran...

Страница 13: ...nition Change in Service ID From this position you can change the PID Number of the chosen service Next it is attached the identification table NID ONID of the main satellites You will be able to find more information in the law ETSI TR 101 162 v1 2 1 Satellite Net ID Original Net ID Description Hotbird 13ºE Eutelsat 13ºE 318 318 Eutelsat 13ºE System Astra 19 2ºE 1 1 Astra Satellite Network 19 2ºE...

Страница 14: ...ave to use the Up and Down buttons of the keyboard Click on OK to edit the selected parameter and Right Left for changing it Once it is configured press OK Satellite input Input Sat In these options you will be able to configure the input parameters of the satellite signal L O freq Local oscillator Selection of the local oscillator that you wish to use FI KU C K9750 K10000 K10600 K10700 K10750 K11...

Страница 15: ...e caused Typical Value according to rules DVB C 15 Options 1 5 1 3 Symbol speed The available symbol speed ranges from 1000 to 7000 S s In order to estimate the output symbol speed you have to take into account the following parameters input modulation input symbol speed input FEC output modulation For example for a 8PSK signal with 22000 MS s and a FEC 2 3 the output symbol speed should be calcul...

Страница 16: ... concerning the transmodulator is given Read log It allows reading the registered events in the module 1 Select the option Read LOG file through Up Down buttons Press OK to continue 2 Press OK again to show the log file 3 A new window will appear It will show the information about the registered events in the module Press the following keys in order to scroll up and down the screen up down Delete ...

Страница 17: ...make the ordination of channels automatically Select a channel through Left Right buttons and introduce the position Press the OK button and the cursor will be placed over the number With the keys of the cursor we can move through all the digits and change the values Press OK in order to save the changes Note If in the existing installation there are already services that have LNC system you will ...

Страница 18: ... to distribute the encoded channels freely you have to install the PCMCIA subscriber card in the Common Interface slot In order to guarantee the right running of the different equipments of the installation we recommend you to provide the inputs and outputs which are not used with a 75 load Accessories Programmer Mod PRO 201 Code 2003123 Field strength meter Mod mediaMAX EVO S2 Code 3001006 Field ...

Страница 19: ...256 QAM Output symbol Rate 1 6 96 MS s Roll Off Factor 13 15 Output channels C2 C69 Output connectores Female F connector Output Level 80 dBuV Regulation margin 15 dB MIX Losses 1 dB Band spurious 60 dBc Programming Interface RJ 45 Programmer PRO 201 media Max EVO and media Max MINI Common Interface Yes 2 slots Operating temperature 0ºC 45ºC Consumption 5V mA 800 Consumption 12V mA 300 Consumption...

Страница 20: ...0 39 05 22 90 97 48 fte fte it www ftemaximal com PORTUGAL Rua José Carlos Ary dos Santos A das Lebres Loures 2670 791 Santo Antão do Tojal Tel 00 351 219 83 87 00 Fax 00 351 219 83 87 09 ftemaximal ftemaximal pt www ftemaximal com ESPAÑA Mogoda 110 Pol Industrial Can Salvatella 08210 Barberà del Vallès Barcelona España Tel 00 34 93 729 27 00 Fax 00 34 93 729 30 73 ftemaximal ftemaximal com www ft...