SPECIFICATIONS

AC SWITCHING:

Solid state zero crossing (no relays that bounce,

arc, and pit)

AC INPUT

120VAC, 60 Hz, 15Amps max.

AC INPUT:

Full line conditioning and RFI suppression

AC OUTLET:

Surge suppression on the outlet

AC OUTLET:

Total output current must not exceed 12
Amps. The AC outlet is rated at 12
Amps but remember that the total cur
rent out of the SPC-15X must not exceed
12 Amps.

SURGE PROTECTION:

Spike  protection modes: Line to neutral, neutral to
ground,line to ground
Spike protection voltage: Max clamping voltage 340V
peak, L-N, N-G, L-G
Response time: 1 nanosecond
Maximum surge current:  >29000 AMPS  (8x20 usec
pulse)
Maximum spike energy: >200 joules
Noise attenuation: Differential 13 dB @ 150 kHz increas
ing to 45 dB @ 30 Mhz
Common mode: 15 dB @ 150 kHz, increasing to >45 dB
@ 30 Mhz

SIZE:

6" x 5 1/2" x 3"

WEIGHT:

4 pounds

Содержание SPC-15X

Страница 1: ...EXP EXP EXP EXP EXPANSION UNIT ANSION UNIT ANSION UNIT ANSION UNIT ANSION UNIT Please be sure to read this manual before using this FSR electronic product Additionally to be sure of obtaining full protection under the terms of the Limited Warranty in the event that your original owner ship documents are lost fill out and return the Warranty Registration Card immediately Also verify that the serial...

Страница 2: ...POWER PRODUCT GROUP Phone 973 785 4347 Fax 973 785 3318 Web www fsrinc com E Mail sales fsrinc com FSR ...

Страница 3: ... degree of protection a SPC 15X can offer depends on the intensity of the strike If lightning strikes a distant power line and causes a relatively small disturbance to reach your location the spike sup pressors in the SPC 15X will absorb the excess voltage invisibly and harmlessly However if lightning strikes the actual building where the SPC 15X is installed or somewhere very nearby some damage m...

Страница 4: ...ot exceed 12 Amps The AC outlet is rated at 12 Amps but remember that the total cur rent out of the SPC 15X must not exceed 12 Amps SURGE PROTECTION Spike protection modes Line to neutral neutral to ground line to ground Spike protection voltage Max clamping voltage 340V peak L N N G L G Response time 1 nanosecond Maximum surge current 29000 AMPS 8x20 usec pulse Maximum spike energy 200 joules Noi...

Страница 5: ...idental or consequential damages resulting from the use or misuse of its products Some states do not allow the exclusion of incidental or consequential damages so the above limitations may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state Warranty claims should be accompanied by a copy of the original purchase invoice s...

Отзывы: