SPECIFICATIONS
AC SWITCHING:
Solid state zero crossing (no relays that bounce,
arc, and pit)
AC INPUT
120VAC, 60 Hz, 15Amps max.
AC INPUT:
Full line conditioning and RFI suppression
AC OUTLET:
Surge suppression on the outlet
AC OUTLET:
Total output current must not exceed 12
Amps. The AC outlet is rated at 12
Amps but remember that the total cur
rent out of the SPC-15X must not exceed
12 Amps.
SURGE PROTECTION:
Spike protection modes: Line to neutral, neutral to
ground,line to ground
Spike protection voltage: Max clamping voltage 340V
peak, L-N, N-G, L-G
Response time: 1 nanosecond
Maximum surge current: >29000 AMPS (8x20 usec
pulse)
Maximum spike energy: >200 joules
Noise attenuation: Differential 13 dB @ 150 kHz increas
ing to 45 dB @ 30 Mhz
Common mode: 15 dB @ 150 kHz, increasing to >45 dB
@ 30 Mhz
SIZE:
6" x 5 1/2" x 3"
WEIGHT:
4 pounds