9
•
Switch B when pressed sends a ¼ second pulse to relay 1 on the leading edge; when released it sends a
¼ second pulse to relay 2 on the trailing edge.
•
Switch C the first press sends a ¼ second pulse to relay 3; the second press sends a ¼ second pulse to
relay 4.
•
Switch D when pressed sends a ¼ second pulse to relay 3 on the leading edge; when released sends a ¼
second pulse to relay 4 on the trailing edge.
•
Switch E has no function.
Quad
Relay
Mode
Mode
Switch
Setting
101
This mode provides the ability to turn on or off all four Relays at once.
Switch A turns on all relays, Switch B turns off all relays, and Switch C toggles all relays. Switch inputs D & E
have no functions.
Special
Function
Mode
Mode
Switch
Setting
111
•
Switch A turns relays 1 & 2 on and sends ¼ second pulse to relay 3.
•
Switch B turns relays 1 & 2 off, and sends ¼ second pulse to relay 4.
•
Switch C first press turns on relays 1 & 2 and pulses relay 3 for ¼ second. The second press turns off 1
& 2, and pulses relay 4 for ¼ second.
•
Switch D the leading edge performs Switch A function, trailing edge performs Switch B function.
Mode Dipswitch 4
Mode Switch 4 determines the control activation state of the 4 relays.
•
S4 set to “1”: Inputs A thru E are active Low. The leading edge is the High to Low transition of the
switch input. The trailing edge is the Low to High transition of the switch input.
•
S4 set to “0”: Inputs A thru E are active High.
The leading edge is the Low to High transition of the
switch input. The trailing edge is the High to Low transition of the switch input.
Содержание INTELLI-TOOLS IT- R4