20
Auto-Switching Mode Configuration
The user may configure the Auto-Switching mode to either FIFO (First Signal
Connected) or LIFO (Newest Signal Connected), using the Set Automode
command. The format is as follows:
Set Automode
“LIFO”|”FIFO”
<cr>
Syntax:
SET AUTOMODE <”LIFO”|”FIFO”> <cr>
Where:
SET AUTOMODE
Automode Request header
“LIFO”|”FIFO” LIFO = Switch to newly connected valid source, FIFO = Maintain
original source
Response from DV-MFSW-21A
: Automode “fifo”|”lifo”
Example:
SET AUTOMODE LIFO<
cr>
To which the DV-MFSW-21
CEC
switcher will respond:
AUTOMODE lifo<cr>
Auto-Switching Mode Request
The user may query the current Auto-Switching mode setting to determine if the
unit is in FIFO (First Signal Connected) or LIFO (Newest Signal Connected)
modes, using the Get Automode command. The format is as follows:
Get Automode
<cr>
Syntax:
GET AUTOMODE<cr>
Where:
GET AUTOMODE
Automode Request header
Response from DV-MFSW-21
CEC
: Automode “fifo”|”lifo”