background image

7 | 

P a g e

 

 

Selecting the Alarm Panel Serial Port Format 

1.

 

Press and hold-down the button on the Hawk PCB until 
the green RUN lamp stops flashing (turns off). 

2.

 

Release the button 

3.

 

Press the button successively until the green RUN lamp 
flashes the correct number of times, indicating the serial 
mode selected 

 

RUN LAMP FLASHES 

SERIAL FORMAT 

Pima 

Paradox 

Texecom 

Rhino 

IDS 

 

Repeat  the  process  until  the  correct  serial  port  format  has 
been selected.  The Hawk will remember the setting. 

 
TEST

 the operation of the radio with the panel after the serial 

port format has been selected. 

 

 

Содержание Hawk

Страница 1: ...installation operation manual ...

Страница 2: ...OWER SUPPLY 5 CHECK AC 5 DRY CONTACTS INPUTS 5 CONTACT ID INPUTS 5 SERIAL PORT 6 SELECTING THE PANEL SERIAL PORT 7 APPENDIX A SERIAL INTERFACE 8 RHINO SERIAL INTERFACE 9 TEXECOM SERIAL INTERFACE 9 PARADOX SERIAL INTERFACE 10 PIMA SERIAL INTERFACE 12 IDS SERIAL INTERFACE 12 SPECIFICATIONS 13 LIMITED WARRANTEE 15 ...

Страница 3: ...k has the option of a remote control receiver which can be used for remote panic functions FEATURES AND FUNCTIONS Contact ID Tip and Ring Telephone interface to all leading control panels Up to 999 zones and 99 partition reporting using the Fast FSK protocol 7 Hardwired inputs with positive trip negative trip or both Input 3 can be programmed to delay an alarm trigger if the panel has siren annunc...

Страница 4: ...the panel Any account code can be programmed into the panel The transmitter will send its own account code The Hawk will send full Contact ID messages all codes partitions and zones using the Fast FSK protocol INSTALLATION Opening the Hawk Cover The plastic cover on the Hawk is opened by inserting a small flat screw driver into the two openings at the top of the cover Gently pull the top of the co...

Страница 5: ...ONES 2 CAC 12V GND 3 5 1 6 7 RING 4 TIP PANEL DIALLER FROM BATTERY 12V DC AC FROM TRANSFORMER SECONDARY ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 RING ZONE 1 TIP HARDWIRED ZONES SERIAL DATA TO PANEL SERIAL DATA FROM PANEL PANEL GROUND ALARM PANEL SERIAL PORT TTL 5V LEVELS ...

Страница 6: ...ct AC voltages between 10 and 24V The AC Failure and AC Restore signals have a programmable delay default 10 minutes in order to prevent false triggers Dry Contact Inputs The dry contact inputs can be used to detect alarms generated from the outputs of the Alarm Panel or from other sources If the external device generates the alarm by pulling the input to ground negative trigger the pull up jumper...

Страница 7: ...UT FUNCTION DEFAULT TRIGGER 1 OPEN CLOSE BY KEYHOLDER 1 HIGH CLOSE LOW OPEN 2 PANIC HIGH 3 DELAYED ALARM HIGH 4 BURG ZONE 1 HIGH 5 BURG ZONE 2 HIGH 6 MEDICAL HIGH 7 FIRE HIGH The inputs can be factory programmed for your particular requirements Serial Port The Hawk can receive alarms from the following alarm panels on its serial port FSK Rhino alarm panels Texecom premier range Paradox E65 SP6000 ...

Страница 8: ...utton successively until the green RUN lamp flashes the correct number of times indicating the serial mode selected RUN LAMP FLASHES SERIAL FORMAT 1 Pima 2 Paradox 3 Texecom 4 Rhino 5 IDS Repeat the process until the correct serial port format has been selected The Hawk will remember the setting TEST the operation of the radio with the panel after the serial port format has been selected ...

Страница 9: ...ngeable The following adapter boards are available ALARM PANEL ADAPTER RHINO No adapter TEXECOM PREMIER Texecom IDS 5 pin IDS Texecom IDS 5 pin PARADOX Paradox 4 pin PIMA Pima 4 pin Hawk Serial Interface Cable GND BLACK 4 3 2 1 1 3 4 2 DATA FROM PANEL BLUE DATA TO PANEL GREEN MOLEX 2510 NOT USED 1 MOLEX 2510 NOT USED 1 WIRES ARE TWISTED TOGETHER WIRE LENGTH 3 0m ...

Страница 10: ...DS Program the Hawk to use the Texecom Serial Alarm Interface DTMF Serial Interface Tab The Hawk is connected to COM1 on the Alarm Panel The following programming is required on the Texecom panel MENU 39 OPTION 3 ON DISABLE ONLINE PRINTING MENU 70 1 2 5 8 ON ENABLE COMMUNICATOR MENU 71 OPTION 3 ON DISABLE ONLINE PRINTING 0 TEL NO 22 YES 1 ACC CODE 3456 YES 2 PROTOCOL TYPE 4 CONTACT ID 3 DIALLER AT...

Страница 11: ... MG5050 and SP6000 alarm panel serial ports Note that the Hawk will not send all the events such as trouble conditions if it is not factory programmed to do so PARADOX FSK ALWAYS SENT EVENT GROUP NO SUB GROUP NO DESCRIPTION 06 Non Reportable Event Telephone Line Trouble Comms Trouble 29 Arming with User 01 32 User Number Close by Keyholder 1 20 30 Special Arming 03 Partial Arming Partial Arming 31...

Страница 12: ...mpered 01 32 Zone Number Fault Zone 1 to 32 YES 44 New Trouble 01 AC Failure AC Fail YES 02 Batt Fail Batt Low YES 04 Bell Current Overload Bell Trouble 05 Bell disconnected Bell Trouble YES 08 Fail To Communicate Tel 1 Fail to Report YES 09 Fail to Communicate Tel 2 Fail to Report YES 10 fail to Communicate Pager Fail to Report 11 fail to communicate voice Fail to Report 46 Bus wireless module ne...

Страница 13: ...ipheral Trouble 53 Wireless Module Sup Trouble Peripheral Trouble 54 Wireless Module Sup Rest Peripheral Trouble 55 Wireless Module Tamper Trouble Peripheral Trouble 56 Wireless Module Tamper Rest Peripheral Trouble PIMA SERIAL INTERFACE Plug the adapter marked PIMA into the serial port on the Pima alarm panel Plug the other end into the Hawk serial port The Pima serial interface will send the sta...

Страница 14: ...ency of Operation Lowband 135 to 156MHz Highband 155 to 175MHz Carrier Power 8W into 50E Frequency Error 1kHz 0 to 55 C Spurious Conducted Components 36 dBm 9kHZ to 1GHz 30 dBm 1GHz to 4GHz Adjacent Channel Power 60dB Frequency Deviation 2 5kHz 2kHz standard Transient Frequency Behaviour To ETSI 300 086 Electrical Power Requirements 13 2V DC Nominal 10 15V 35mA Standby 1 6A Transmitter Active Low ...

Страница 15: ...fe but hand it in at an official collection point for recycling The on board battery also contains substances that may pollute the environment Always remove the battery before you discard and dispose of the battery at an official collection point for batteries Physical Dimensions 107x136x46mm without antenna Housing Plastic with steel insert for RF earthing Packaged Weight 300g Packaged Dimensions...

Страница 16: ... defects in materials and workmanship under normal use and service for twelve months from the date of original purchase Seller s obligation shall be limited to repairing or replacing at its option free of charge for materials or labour any part which is proved not in compliance with Seller s specifications or proves defective in materials or workmanship under normal use and service Seller shall ha...

Страница 17: ...ur or that there will be no personal injury or property loss as a result Consequently seller shall have no liability for any personal injury property damage or other loss based on a claim the product failed to give any warning However if seller is held liable whether directly or indirectly for any loss or damage arising under this limited warranty or otherwise regardless of cause or origin seller ...

Страница 18: ...www fsk co za 14 Richard Road Industria North Johannesburg South Africa T 27 0 11 477 2600 E sales fsk co za Innovative technology by FSK Electronics Call Center 0861 105 962 ...

Отзывы: