background image

GLOBAL

INSTALLATION &

OPERATION 

MANUAL

Содержание Falcon Global

Страница 1: ...GLOBAL INSTALLATION OPERATION MANUAL ...

Страница 2: ...V1 0 08 Jul 2021 ...

Страница 3: ...lcon Global Wiring 7 3 1 1 Power Supply 8 3 1 2 Check AC 8 3 1 3 Dry Contact Inputs 8 3 1 4 Contact ID Inputs 9 3 1 5 Serial Port 9 3 2 Falcon Global Installation 10 3 3 GSM Connection and Signal Strength 10 3 4 Selecting the Alarm Panel Serial Port Format 11 3 5 Indicators and Controls 14 6 2 4 Indicators Controls 6 3 1 6 Relay Outputs 10 ...

Страница 4: ...APPENDIX A Serial Interface 18 4 2 PC based Programmer 17 APPENDIX B Programming Cable Software 24 4 PROGRAMMING 17 4 1 Onboard Push Button 17 ...

Страница 5: ...s the universal Contact ID interface to alarm panels as well as a serial interface to leading panels It also has seven dry contact input triggers In addition the Falcon Global has two dry contact relay outputs which can be used to command alarm panels and other devices These outputs can also be controlled via the MiFalcon mobile application 1 INTRODUCTION Falcon Global Installation and Operation M...

Страница 6: ...telephone interface to leading control panels Ÿ Serial alarm interface to leading control panels Ÿ Over the air panel uploading and downloading on the Rhino and Texecom Premier control panels through the serial interface 2 3 Programming Ÿ Full programming and software updating via a computer serial port Ÿ Programming over the air via GPRS 2 4 Indicators and Controls Ÿ Status and error indication v...

Страница 7: ...ALLATION 3 1 Falcon Global Wiring Connections to the Falcon Global are shown below SERIAL CAC 12V GND 1 2 3 4 5 6 7 C1 C2 NO1 TIP RING T R NO2 GLOBAL GLOBAL Falcon Global Installation and Operation Manual I 7 ...

Страница 8: ...put will detect AC voltages between 10 and 24V If the CAC line is not connected the Falcon Global should not be programmed to send AC Failure or Restoral Signals The AC Failure and AC Restore signals have a programmable delay default set at 1 minute in order to prevent false triggers 3 1 3 Dry Contact Inputs The dry contact inputs can be used to detect alarms generated from the outputs of the alar...

Страница 9: ...d to use its dialer and the option for reporting must be set to Contact ID Refer to the programming manual of the applicable alarm panel 3 1 5 Serial Port The Falcon Global can receive alarms from the following alarm panels on its serial port Ÿ Rhino 816 and Rhino 68 alarm panels Ÿ Texecom premier range panel uploads and downloads can also be done Ÿ Paradox SP MG Series Ÿ Pima Ÿ IDS805 IDS X Serie...

Страница 10: ...GSM network The Falcon Global will send alarms quicker and more reliably if it has a strong connection to the GSM service provider For the software version 4 20 and hardware version A 3 1 6 Relay Outputs Two dry contact relay outputs are available on the Falcon Global These outputs can be commanded to turn on and off via the GSM network The outputs are rated at 24V AC or DC up to a maximum current...

Страница 11: ...t will start connecting to the network displaying its status as it initialises and connects see section 3 5 Indicators and Controls Falcon Global Installation and Operation Manual I 11 Connected on network with priority 1 signal strength 6 The minimum signal strength required for good remote connectivity is 5 3 4 Selecting the Alarm Panel Serial Port Format The alarm panel serial port can be selec...

Страница 12: ...To change the serial port format Ÿ Remove the power from the Falcon Global Ÿ Hold down the push button and re apply the power Ÿ Release the button then push the button to cycle through the panel serial port settings until the correct serial port is displayed Ÿ Leave the button for 15 seconds The Falcon Global will remember the new serial port format See table on next page GLOBAL I Falcon Global In...

Страница 13: ...Neo Series S Sherlotronics DISPLAY SERIAL FORMAT Pima Hunter Pro F Texecom Premier t P Rhino Paradox r i IDS b DSC Power Series E IDS805 FSK Key bus GLOBAL Falcon Global Installation and Operation Manual I 13 ...

Страница 14: ...s DISPLAY SERIAL FORMAT Risco LightSYS 2 A DESCRIPTION CHARACTER FLASHED STATUS The communicator is starting the GSM modem Initialising i Restarting r The communicator is connecting to the GSM network The is communicator re starting the GSM modem c lower case Connecting GLOBAL I Falcon Global Installation and Operation Manual 14 Orisec O ...

Страница 15: ...CTER FLASHED STATUS Falcon Global Errors If the Falcon Global detects an error it will flash the error code on the seven segment display DESCRIPTION CHARACTER FLASHED STATUS E1 SIM card not found The communicator has not detected a SIM card which it has been programmed to use Falcon Global Status cont Connected The communicator is connected to the GSM network and is ready to send alarms C upper cas...

Страница 16: ...repaired No SIM card Server connection failed The communicator cannot connect to the server to route the GPRS message to the control room Make sure that the programming of the Server GPRS settings are correct The GSM network may be experiencing technical problems Contact the manufacturer The communicator cannot connect to the server to send the alarms Connection to server has failed E4 DESCRIPTION...

Страница 17: ...The Falcon Global programmer requires a PC running Windows XP or above with an available USB Port The FSK USB programming cable is required to program the Falcon Global see Appendix B To program the unit Ÿ Push and hold down the push button for more than 7 seconds Ÿ The display will now show Pr to indicate that it is in programming mode Ÿ The unit will stay in this mode for 20 seconds to allow pro...

Страница 18: ...rchangeable The following adapter boards are available VERY IMPORTANT Plug the adapter board into the alarm panel and NOT the Falcon Global ALARM PANEL ADAPTER Rhino Texecom Premier IDS Paradox Pima Pima 4 pin Paradox 4 pin Texecom IDS 5 pin No adapter Texecom IDS 5 pin DSC Neo DSC Neo 5 pin DSC Power Series IDS805 DSC Power Series IDS805 FSK Key Bus Module DSC Power Series IDS805 FSK Key Bus Modu...

Страница 19: ...mat to Texecom on the Falcon Global Refer to Section 3 4 Connect the Falcon Global to Com1 on the alarm panel using the serial interface cable with the TEXECOM IDS adapter board TEXECOM SERIAL INTERFACE GLOBAL Falcon Global Installation and Operation Manual I 19 ...

Страница 20: ...on Global Please refer to the FSK APN USER GUIDE PARADOX SERIAL INTERFACE The Falcon Global can send alarms received from the serial port of the Paradox SP65 E65 MG5050 and SP6000 alarm panels Set the serial port format to Paradox on the Falcon Global Refer to Section 3 4 Plug the adapter marked PARADOX into the serial port on the Paradox alarm panel Plug the other end into the Falcon Global s ser...

Страница 21: ...l s serial port Proceed to program the panel as per the Falcon Connection App Set up Guide provided for alarm signals to be sent and or DSC POWERSERIES FSK KEY BUS MODULE The Falcon Global can send alarms received from the keypad bus of the DSC PowerSeries alarm panel Wire the DSC PowerSeries FSK Key bus Module to the keypad bus on the alarm panel and then connect the 4 pin molex connector to the ...

Страница 22: ...ERIES SERIAL INTERFACE Set the serial port format to IDS on the Falcon Global Refer to Section 3 4 Proceed to program the panel as per the Falcon Connection App Set up Guide provided for alarm signals to be sent and or for app connectivity RISCO LIGHTSYS 2 SERIAL INTERFACE The Falcon Global can send alarms received from the RS232 com port of the Risco LightSYS 2 alarm panel with firmware version 3 ...

Страница 23: ...lcon Global can send alarms received from the COM 1 serial port of the Orisec alarm panel with a firmware version of 4 52 or later Plug the side of the serial cable labelled panel side into the serial port of the Orisec alarm panel Plug the other end into the Falcon Global s serial port NB Connecting the wrong end of the cable to the wrong device will damage the device ...

Страница 24: ...rogramming Cable and FSK DVD kit which contains the programming software FSK Item Code 40027 Installing the drivers for the FSK USB to UART Programmer Install the drivers before plugging the USB Programmer into the computer s USB port GLOBAL I Falcon Global Installation and Operation Manual 24 ...

Страница 25: ...B Serial Adapter Drivers For 64 bit operating systems double click on CP210xVCPInstaller_x64 exe Otherwise double click on CP210xVCPInstaller_x86 exe Follow the instructions on DRIVER software to install GLOBAL Falcon Global Installation and Operation Manual I 25 ...

Страница 26: ...click on the setup exe application and follow the instructions Upon opening the software for the first time it will require an initial setup The following window will pop up Select the folder where the templates will be saved for Falcon Global devices GLOBAL I Falcon Global Installation and Operation Manual 26 ...

Страница 27: ...will be used to communicate with the device From there the following window will appear Connect the Falcon Global to the correct COM port and click on the read button GLOBAL Falcon Global Installation and Operation Manual I 27 ...

Страница 28: ...Upon completion the window will look like this All the settings that are greyed out cannot be changed GLOBAL I Falcon Global Installation and Operation Manual 28 ...

Страница 29: ...All the input and output settings can be changed by clicking on the Input Output Settings Tab GLOBAL Falcon Global Installation and Operation Manual I 29 ...

Страница 30: ...e face hereof In no case shall seller be liable to anyone for any consequential or incidental damages for breach of this or any other warranty express or implied or upon any other basis of liability whatsoever even if the loss or damage is caused by its own negligence or fault Seller does not represent that the products it sells may not be compromised or circumvented that the products will prevent...

Страница 31: ......

Страница 32: ...Amecor House 14 Richard Road Industria North 1709 helpdesk fsk co za 27 11 477 7705 technical support ...

Отзывы: