DIT LUTs

DM series monitors are capable of loading multiple custom DIT LUTs which do not require you to profile the panel. You can 

use Lattice, the main component of Light Illusion’s LightSpace, or LightSpace FSI LUTs software to convert and export LUTs 

in the FSI format. The LightSpace workflow is shown below.

Open LightSpace CMS

Select File > Import > YourLUT

Select File > Export > Choose FSI17_32bits (*.dat) as the export format.

In Lattice you should select .dat V2 as the export type.

Once the file is saved, change the file name to ditXX.dat where XX is a 2 digit 

number ranging from 00 to 16. The monitor can store up to 16 DIT LUTs at a 

time. The naming structure is ditXX.dat with valid LUT names ranging from 

dit01.dat to dit16.dat.

Содержание DM Series

Страница 1: ...1 678 835 4934 Fax 1 678 804 1882 E Mail Support FlandersScientific com www FlandersScientific com DM Series DM170 DM240 DM250 This manual is based on firmware version 1 1 04 2231 If you have an older or newer firmware version some of the functions mentioned in this manual may not be present or may operate differently ...

Страница 2: ... System Status 7 Function Menu 8 20 Real Time Scopes Menu 21 Scopes Audio Meters Menu 22 24 Video Menu 25 27 Audio Menu 28 Marker Menu 29 Alarm Menu 30 31 OSD Menu 32 GPI Menu 33 Color Management menu 34 36 System Menu 37 38 Troubleshooting Guide 39 40 Appendix A DIT LUTs 41 42 Appendix B Calibration LUTs 43 44 Appendix C Ethernet Connectivity 45 ...

Страница 3: ...ng the same characteristics and performance specifications as the original parts Use of unauthorized parts can result in fire electric shock and or other damage Upon completion of any service or repair work request that the service technician perform safety checks to ensure that the product is in proper working order When mounting the product to a wall ceiling or within a rack enclosure be sure to...

Страница 4: ...urces such as radiators heaters stoves or other heat generating products Avoid prolonged exposure to direct sunlight as this can cause damage to the panel FCC Federal Communications Commission This equipment has been tested and found to comply with the limits for a class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful...

Страница 5: ...sed to navigate On Screen Menu RIGHT ENTER Used to navigate On Screen Menu and to confirm selections within the On Screen Menu PHASE H POS Used to adjust phase Pressing down on the center of this button will return the setting to default Hue is locked by default on SDI but can be unlocked by the SDI Hue Adjustment option on the System Menu CHROMA V POS Used to adjust chroma higher or lower Pressin...

Страница 6: ...ction reserved for future use USB Type B USB device connection used for moni tor update DVI DVI D Input DP Display Port Input SDI In 1 SDI In 2 Two Autosensing Autoswitching Multi Format 3G HD SD SDI Inputs SDI Out 1 Out 2 Two looped 3G HD SD SDI Out puts MON Out Processed output with DIT LUT applied if active Capable of Cross Conversion with Displayport or DVI selected as the active input Audio I...

Страница 7: ... exit the menu or back out of a sub menu simply press the MENU button System Status The System Status menu does not contain any configurable settings but does provide important information regarding your monitor s serial number firmware version current configuration Main Menu System Status Function Input SDI 1 Real Time Scopes Video Format 1080p 60hz Scopes Audio Meters PAP Input SDI 2 Video Video...

Страница 8: ... a function to a function key highlight one of the 6 Function lines and press ENTER A list of assignable functions will appear Select the desired function with the UP and DOWN buttons and press ENTER to assign that function to the corresponding function key The Function Display option at the bottom of the Function Menu gives you the option to have a temporary confirmation window appear on screen a...

Страница 9: ...osition Vectorscope Position Position 1 Default Waveform Only Digital Levels Upper Left Upper Left Position 2 Vectorscope Only Voltage Levels Upper Right Upper Right Position 3 Waveform Vectorscope IRE Lower Left Lower Left Position 4 HDR ST2084 Levels Lower Right Lower Right Button Press Background Reserved Waveform Size Vectorscope Size Position 1 Default Solid Reserved Small Small Position 2 Tr...

Страница 10: ...ction is designed for use with cameras that output Start Stop Record flags in the ancillary data of their serial digital output To activate this function set Rec Status Tally to a function button and press that function button once While active the monitor s red tally light will turn on when the Start Record SDI flag is detected and will turn the red tally light off when the Stop Record SDI flag i...

Страница 11: ...mapping function With both Pixel to Pixel mapping and Overscan selected the area outside of the active scan will simply be blacked out but the active video will not be scaled outside of the 1 1 pixel scan With Pixel to Pixel mapping off and overscan on the active scan area will be scaled full screen To view all active lines in Pixel to Pixel mapping mode make sure to turn Overscan off Pixel to Pix...

Страница 12: ... allow you to view any portion of an incoming 2K source in an unscaled 1 1 onscreen representation 2 1 Pixel Mapping SD sources only Every individual pixel of the incoming source is represented by four pixels onscreen This scaling algorithm is simple and allows for a largely artifact free double size version of the 1 1 Pixel Mapping Mode for SD sources While 2 1 scaling will still not fill the ent...

Страница 13: ...m on any portion of an HD signal LUM Coloring This function generates an artificial luminance map of the incoming source that can be particularly useful in identifying overexposed areas in any given shot An onscreen scale helps indicate what artificial color corresponds to what lumi nance level The scale will follow the selected Waveform Scale set in the Scopes VU Meters Profile 1 you can choose f...

Страница 14: ...alue between 0 255 for 8 bit and 0 1023 for 10 bit B Blue level as an absolute value between 0 255 for 8 bit and 0 1023 for 10 bit You can also press the Ref POS rotary knob to set a reference position onscreen Once your reference position is set it will be indicated on screen by a separate crosshair and you will be able to move the active crosshair to obtain a real time readout of your current an...

Страница 15: ...F POS rotary knob toggles you between YCbCr and RGB data readouts Turing the REF POS rotary knob toggles between decimal and hexadecimal data readouts Turn the F STOP rotary knob to toggle between 8 bit and 10 bit data readouts Pressing down on the F STOP rotary knob will cause the green position rectangle to flash white on screen to make it easier to locate The Video Data function can also be use...

Страница 16: ...n current reference expressed as dE2000 value You can press the Ref POS rotary knob to define a reference position on screen Once your reference position is set it will be indicated on screen by a separate crosshair and you will be able to move the active crosshair to obtain a real time readout of your current and reference positions as well as a separate readout of the precise difference between ...

Страница 17: ...en Blue or as monochrome Still Frame This function allows you to freeze a video source at anytime To unfreeze simply press the function key assigned to Still Frame a second time Variable Wipe When monitoring a Level B 3Gbps SDI signal monitor must have 3Gbps SDI Input comprised of two multiplexed 1 5Gbps HD SDI signals the monitor will allow you to view these signals in a vertical or horizontal sp...

Страница 18: ...omething that does not look flat These modes are not a replacement for full 3D LUT transforms and not a substitution for proper color correction in post production applications For more advanced Log mode normalization use a custom 3D DIT LUT On Screen Tally When activated this function will generate an onscreen box that mirrors the status of the physical tally on the monitor s bezel This can be pa...

Страница 19: ...ge window red background and DSLR in 1080i Preview with DSLR Zoom feature Off DSLR in 1080i Preview with DSLR Zoom Feature On DSLR in 480p Record Mode with DSLR Zoom feature off DSLR in 480p Record Mode with DSLR Zoom feature On enhanced timecode display large timecode overlay window Please note that as with the standard Alarm Monitoring feature the monitor may respond slowly to user toggles input...

Страница 20: ...n go to the Video Menu and select your desiredAnamorphic Desqueeze mode Anamorphic Desqueeze Modes Activating this function will enable an Active Format Description reader on the monitor that will provide both a text readout of AFD data and display corresponding markers onscreen indicating the portions of the image described by the AFD code If no AFD data is present while this feature is active th...

Страница 21: ...windows Select from Black Translucent and Transparent Display Window Choose to display Luminance Window Vectorscope Window or Both Lum Win Pos Vector Win Pos Set the position of the corresponding window Selections include Bottom Right Bottom Left Top Right and Top Left Lum Win Size Vector Win Size Set the size of the corresponding window 1x or 2x Lum Win Style Set the graticule mode of the Luminan...

Страница 22: ...pe windows can be displayed simultaneously so you can view any two of the following modes at the same time Luminance Standard Waveform Vector Scope Hue Vector RGB Parade GBR Parade RGB Overlay YCbCr YCbCr Overlay Column YRGB Peak Histogram Color Histogram RGB Histogram Audio Loudness Audio Phase and Vertical Audio Level Meter Please note that displaying two Scope Windows at the same time will caus...

Страница 23: ...t side of the screen When organized in groups the channels will be arranged with all channels of an Audio Group displayed on the same side of the screen together Alignment Level Allows audio level meter alignment level to be set to 12dBFS 14dBFS 16dBFS 18dBFS or 20dBFS 22dBFS Permitted Max Level Allows you to specify the Max Audio Level for your onscreen Audio Level Meters Select from 10 dBFS 9 dB...

Страница 24: ...eturn to Table of Contents Scopes Audio Meters Luminance Vector Scope Hue Vector RGB GBR Parade Color Histogram YCbCr RGB Histogram Column YRGB Peak Histogram YCbCr Overlay RGB Overlay Audio Phase Meter Audio Level Meters Audio Loudness ...

Страница 25: ...ng Auto from the SDI Format menu selecting the appropriate format manually from the SDI Format Menu or simply toggling to another input and back to the input in use Please note that on monitors with a selectable color space option that XYZ signals will be mapped to the color space selected on the Color Management menu 3G Level B When monitoring a 3Gbps SDI Level B signal comprised of two distinct ...

Страница 26: ...esqueeze ratios This is used in conjunction with the Anamorphic Desqueeze function described in the Function Menu portion of this manual Signal Mode Selecting Film for this setting allows the monitor to compensate for material with 2 3 pulldown to provide a smoother image Selecting TV for this setting processes the incoming video signal with no 2 3 pulldown compensation Selecting Auto will automat...

Страница 27: ... with 2nd field for display on screen Black Insert Inserts black field for nearly instantaneous display of source This mode may result in a slight drop in overall image luminance Half LUM Inserts a half light field for nearly instantaneous display of source with less impact on overall luminance than Black Insert This mode looks very similar to a CRT owing to a CRTs average pixel decay fall time Fi...

Страница 28: ...ill be the stereo pair shown when the Audio Phase Meter is activated on the SDI 2 Input DVI D Audio Allows you to select between Analog Audio input via minijack connector or No Sound when DVI Digital is the selected video input You can also use the Channel 1 2 selection listed here for stereo HDMI audio support when using a HDMI or Display Port to DVI cable DP Audio Allows you to select between An...

Страница 29: ...nd function described below is set to Normal Safety Marker Use the Safety Marker function to toggle the size in percentage of the safety marker displayed This option can be used by itself or in conjunction with the Area Marker function provided that the Marker Background function described below is set to Normal The Safety Marker may be displayed relative to the incoming source or the Area Marker ...

Страница 30: ...ents that will be monitored This selection only affects onscreen visual alarms and does not change what alarm events can be monitored through the remote control alarm monitoring software Safety Alarm Will trigger an alarm if a loss of signal is detected a full black field is detected a full blue field is detected and or embedded audio goes mute for the amount of time specified in the Audio Trigger...

Страница 31: ...e ID on the monitor s OSD menu or based on remotely set UMD information over RS232 or RS422 You may also turn the selection to off to remove the Source ID overlay UMD Color Only applies to Safety Broadcast feature Toggles the Source ID text color between White and Black UMD Position Only applies to Safety Broadcast feature Select top or bottom of screen Please note that when Timecode Overlay is ac...

Страница 32: ... or Top Right Status Position Changes position of onscreen status display window Select from Top Left Top Right Bottom Left Bottom Right or Center Rotary Position Changes position of onscreen window indicating status of any rotary knob Volume Contrast etc during adjustment Select from Top Center or Bottom Source ID Allows you toggle source ID function on off The Source ID function can be used to s...

Страница 33: ... of the GPI slots 1 through 7 and press ENTER to generate a list of available functions that can be toggled using the GPI interface 87654321 When looking at the GPI RJ 45 Connector located on the back of the monitor the pins are arranged 1 through 8 from right to left This GPI interface is a contact closure based system and PIN 5 is always the ground The GPI numbering on the GPI menu corresponds t...

Страница 34: ...lor temperature You can instantly toggle between 3200K 5000K 5600K 6500K and 9300K 6500K is the default setting Please note that in DCI P3 mode the monitor will override this manual setting Attempting to select a Color Temperature setting manually with DCI P3 mode active will result in the monitor exiting DCI P3 color space mode Color Matching Alternate CMF Selection for OLED Monitors FSI s OLED m...

Страница 35: ...lider in Custom mode will respond slower if you are in Judd Modified color matching mode on an OLED monitor If you need to make large changes to the default Luminance slider position it may be faster to first switch to CIE 1931 before adjusting the setting LUT Bypass Used when creating custom LUTs See Appendix A or B or contact FSI Support for more information about LUT creation Update LUT Used to...

Страница 36: ...ustment but should you wish to have such an adjustment in SDI you should set this option to On Factory AWB Used at the factory level or with the CA310 DCAA kit Not used for 3D LUT based calibration with third party calibration software Reset Factory Alignment The password protected Reset Factory Alignment option is for use by FSI and or authorized FSI service centers only This option does not rese...

Страница 37: ...ew firmware file has been loaded to the monitor Keypad LED Allows you to turn off the LED lights on the Monitor s Keypad Select from Normal All Off and All On In the default Normal mode active keys will illuminate In All Off mode no keys will illuminate In All On mode all keys will stay illuminated and will flash when activating or deactivating a function Chroma Bright Contrast When set to Lock th...

Страница 38: ... Contrast Unlock Marker Luminance Interval On Alarm Language English OSD DHCP On GPI IP Address 192 168 001 111 Color Management Subnet Mask 255 255 255 0 System RS422 Address 1 System Status Baud Rate 9600 Support Parity None RS422 Address Baud Rate Parity Set the monitor s RS422 address for remote control and alarm monitoring Baud Rate should remain at 9600 and Parity at None unless otherwise sp...

Страница 39: ...tting this to Interlaced greatly reduces process ing delay Normal Mode processing of fers the best balance between ancial lary feature speed e g scopes and video processing speed Fast Mode can reduce video processing even fur ther but pulls processing resources away from scopes and other ancillary features so menu artifacts and slower scope update speeds may occur How ever there is no loss in vide...

Страница 40: ...g Processing to Fast Mode on the Video Menu can further reduce vid eo delay You can also use the monitor s audio out to ensure perfect audio video sync as disembedded audio is always de layed by the exact amount of video procesing time Image is flickering On OLED units verify that Flicker Free Mode is turned ON With all monitors verify the frame rate being received on the System Status menu If int...

Страница 41: ...tware to convert and export LUTs in the FSI format The LightSpace workflow is shown below Open LightSpace CMS Select File Import YourLUT Select File Export Choose FSI17_32bits dat as the export format In Lattice you should select dat V2 as the export type Once the file is saved change the file name to ditXX dat where XX is a 2 digit number ranging from 00 to 16 The monitor can store up to 16 DIT L...

Страница 42: ...ect Menu Color Management Update LUT to save the LUT s Once saved the DIT LUTs can be turned on off by assigning DIT 3D LUT to a funciton key You can also simply use the up and down arrow keys while the DIT LUT function is active to toggle between 3D DIT LUTs you have loaded to the monitor NOTE When a DIT LUT is active it will impact the Scope and Measurement feature values accordingly to reflect ...

Страница 43: ...t setting the Color Matching Function Color Management Menu selection to CIE 1931 for profiling and 3D LUT creation Once calibration is complete you can switch to Judd modified if you prefer to operate with a Judd modified CMF based calibration When using LightSpace to generate custom user LUTs for FSI monitors the colorspace image name typed into the Convert Color Space Window MUST match your mon...

Страница 44: ... s you created to the monitor All 3 LUTs can be transfered at one time Once the file has finished transferring on the monitor go to Menu Color Management Update LUT Press ENTER to begin the process and confirm with Yes when the monitor prompts you Color Management Luminance 100 LUT Bypass 3D LUT Update LUT Red Gain 50 Green Gain 50 Blue Gain 50 Once the monitor has rebooted set LUT Bypass to None ...

Страница 45: ... address and subnet mask Note When changing static IP addresses you must power cycle the monitor to set the new IP address Direct Connection DM Series Monitors can also be connected directly to your PC or Mac via ethernet connection To directly connect you must assign static IP addresses to your monitor and to your computer using the same subnet mask The IP addresses must be different for each dev...