© 2015 Flanders Scientific, Inc.
15
Function Menu
CIE Scope
This function maps out full frame signal data on a CIE diagram.
Signal levels are mapped out relative to your active color space
selection on the Color Management menu. Your active color
space selection is represented by a black trinagle on the CIE
diagram.
If you have one of the custom User Color Space selections active
then this reference gamut will default to Rec709. In addition
to the primary color gamut indication (black triangle) you can
press down on the V POS rotary knob to generate a secondary
color gamut overlay as a grey triangle. This secondary color
gamut overlay is purely for comparative reference and does not
influence how signal levles are mapped relative to the primary
color gamut selection.
The CIE diagram may be toggled between CIE 1931 and
CIE 1976 views by pressing down on the H POS rotary knob.
Please note
that this is a very processor power intensive feature and video quality, specifically video sharpness, will
be degraded while active. For this reason we suggest using the CIE Scope feature as needed for specific color gamut
analysis, but we do not reccomend leaving the feature enabled at all times.
4K Display (CFE2 Units Only)
This feature is currently in limited beta testing only. Further support & documentation may be offered in conjunction with
future firmware releases.
3D Disparity
This feature only works when SDI 1 and SDI 2 are the same frame rate / resolution and are genlocked. When active a
disparity view will be shown on screen highlighting the difference between SDI 1 and SDI 2.