Accessories and Applications

AdjustableL&ZBracketispartoftheMEM2400LEDKit.

4

174

174

41

50.5

45

Trouble Shooting

Incorrect voltage.

Check voltage jumper setting.

Check power and loose wiring.

No DC voltage to lock.

Door will not lock

Too much back 
pressure when 
power is off

PROBLEM

POSSIBLE CAUSE

SOLUTION

Incorrect wiring connection.

Security top sleeve nut higher than 
magnet surface.

Back pressure exerted on the MEM lock 
not allowing the magnetic lock to retract 
back to its original position.

Avoid applying continuous pressure on the door when 
closed. Realign the door.

Screw fix the security top sleeve nut level with surface 
with the provided key screw and apply thread-locker-glue.

Check wiring, refer to wiring instruction.

Содержание MEM2400LED

Страница 1: ...pening Doors Functions The MEM2400LED Mechanical Electro Magnetic Lock operates on either 12 or 24 VDC It is set ex factory on 24VDC and can be changed over to 12V DC by voltage jumper selection When power is applied to the lock and the door is in the closed position the Armature Plate is magnetically attracted to the MEM device and both the DSS LSS switches change status to NC When pressure is ap...

Страница 2: ...nto the tapped hole of the Z Bracket C Note The Armature plate when tightened must remain flexible and be allowed to float as mentioned above 3 Install the End Cap D onto the Countersunk hex screw A Armature Plate Installation Instructions Installation diagram 2 Key screw Spring Pivoting Pin Countersink hex screw A Applied drop wise of provided threadlockers glue to the thread of the security slee...

Страница 3: ...afety Precaution Using the template provided secure the MEM2400LED MEM Lock firmly on the door frame with the provided screws and have it checked periodically for any possible screw loosening MEM2400 LED Output and Indication Status Table Condition Serial number 1 2 3 4 5 Power OFF Door Closed Power OFF Door Open Power On Door Open Power On Door Closed Power On Door Closed Tampered DSS EW1 EW2 LSS...

Страница 4: ... when power is off PROBLEM POSSIBLE CAUSE SOLUTION Incorrect wiring connection Security top sleeve nut higher than magnet surface Back pressure exerted on the MEM lock not allowing the magnetic lock to retract back to its original position Avoid applying continuous pressure on the door when closed Realign the door Screw fix the security top sleeve nut level with surface with the provided key screw...

Отзывы: