membrane is deemed to be ‘expired’ if the overall reduction rate is <85% (as a general rule). To apply this 
to the above example, 200 – 85% = 30mg/L. So, if your test reading was approaching 30mg/L or higher, it 
would be time to change the membrane. 

Troubleshooting 

Problem 

Possible Cause(s) 

Solution 

Leaking between 
fitting & tubing 

Unseated Tube 

Check all tubing connections by firmly pushing them into the 
fitting. Check that there are no kinks or any obvious issues. If 
the problem persists, remove the tubing and check for a clean 
cut with no burs. Push the tubing back in and try again. If this 
does not work please contact customer support. 

Leaking from 
Feed Water Valve 

1. Damaged or 
Missing Washer 
 
 
2. Not Tight 
Enough 
 
 
 
 
 
 
3. Thread is too 
Short 

1. Check the valve to see if the washer is inside, if it is 
damaged it may need replacing – this is a common size 
washer and can be purchased from most hardware/plumbing 
stores. 
2. If the diverter valve is loose (or you can easily swivel the 
fitting without resistance, the fitting is not tightened enough. It 
may feel like you can’t tighten it anymore and it just keeps 
spinning but if you use a gripping tool (multi grips) to grab the 
collar of the fitting and use your hand to hold the valve itself 
steady, you will be able to further tighten the valve. The valve 
is tight enough when you feel light to moderate resistance 
when trying to swivel the valve. 
3. If you screw the valve on and the collar ‘bottom’s out’ on the 
tap, you may need to add another washer (to bulk up the 
space). 

The unit is not 
producing any 
water? 

1. Water Supply is 
off or 
disconnected. 
 
2. Pre-Filter has a 
blockage 
 
3. Insufficient 
Water Pressure 
 
4. Water Quality 

1. Turn on the water supply and ensure there are no 
obstructions to the water flow. 
2. Disconnect the tube between the membrane and pre-filters 
and run water at full pressure to see if water comes out of the 
filter. – If the water does not come out (or is very weak 
pressure) the filter may need to be changed. 
3. Low Pressure Reverse Osmosis requires 25psi (Minimum) 
to operate – 70psi is ideal. If you have lower than 25psi 
pressure this unit may not be suitable for you. 
4. Ensure that the water quality meets the feed water 
requirements outlined previously. High levels of impurity such 
as hardness and salt can cause the system to block or not 
produce water. 

I am getting much 
more waste water 
than filtered water 

1. Water Pressure 
 
 
 
2. Water Quality 
 
 
3. Blockage 

1. Our units are designed to run at approx. 1:1 – 1:2 waste 
water ratio at 50 psi. If your pressure is lower than 50 psi, the 
production rate may decrease and cause more drain water 
than filtered water. 
2. If your inlet water quality is poor and contains higher salts 
and hardness the filter may produce less water than the 
specified amount. 
3. If you have good pressure, and average water quality it is 
possible there is a small blockage somewhere in the system. 
Try to follow the water flow along the system, disconnecting 1 
tube at a time to try and pinpoint where the water is ‘stopping’ 

High pH Reading 

1. Alkaline Filter 
    (If Applicable) 
 
2. GAC Filter 
 
 
 
 

1. Alkaline Filters are designed to increase the pH of the water. 
When the filter is new it will be high but will soon settle to the 
advertised levels after adequate flushing. 
2. If you have a post GAC filter (Carbon), this will naturally 
increase the pH of the water. pH is the measure of Hydrogen 
in the water and this hydrogen will vent off the water if you 
leave it to stand and the pH will then drop back down to the 
normal level. 

Содержание GT1-70

Страница 1: ...ter Connection 3 II Drain Clamp 3 III Drilling Faucet Hole Stainless Steel Sink 3 IV Mounting the Faucet 4 V Storage Tank Assembly 4 VI Assembling the System 5 Connecting the RO System 5 I Tubing 5 Sy...

Страница 2: ...ssure 175 kPa 700 kPa Temperature 4 5 C 38 C pH Level 2 11 TDS 0 mg L 2 000 mg L Iron 0 mg L 0 3 mg L Manganese 0 mg L 0 1 mg L Hardness 0 mg L 200 mg L III Space Requirements System Dimensions Height...

Страница 3: ...tween DO NOT apply thread tape to these connections as they are designed to use the washers only Thread tape is only required on the male thread of the FWA if it is not installing to a flex line With...

Страница 4: ...tance thread the Compression nut over the tubing followed by the cone washer Then firmly press the gasket into the end of the tubing You can then insert the tubing into the base of the faucet and secu...

Страница 5: ...t the faucet due to the low flow rate of the membrane The drain line however should begin to run as soon as water reaches the membrane 5 When the water first comes out of the tap it will be grey and d...

Страница 6: ...e first 45 seconds of water If the system has been shut down for over 1 week discard a full tank of water Maintenance I Replacement Parts Filtration tubing should be replaced periodically about every...

Страница 7: ...Water Quality 1 Turn on the water supply and ensure there are no obstructions to the water flow 2 Disconnect the tube between the membrane and pre filters and run water at full pressure to see if wate...

Страница 8: ...of the water especially when new If you have low TDS water already it is possible for the TDS level out of the alkaline filter to be higher than your inlet water This is because you are adding mineral...

Страница 9: ...suddenly stopped or forced in other directions by fast closing valves Sioux Chief shock arresters are best used at the point of shock and should be installed as close to the valve or piping where the...

Страница 10: ...stems must be installed by a qualified plumber The consumer is responsible for keeping record and proof of installation in the form of an invoice and or receipt Filter systems must be maintained as pe...

Страница 11: ...to terms and conditions outlined below This extended warranty covers the below parts of the system GT8 0S Twin O Ring Housings GT8 31 Reverse Osmosis Housing GT35 12 NPT Stainless Steel Centre Joiner...

Отзывы: