the water reducing the RO water back to a 0 TDS reading. The filter media will require changing once the 
TDS exceeds your required limit. To change the DI media: 

 

Inline DI Filter:

 Disconnect the tubing from the inline filter and remove the filter from its mounting 

clamps. Unscrew the end cap in an upright position and remove the sediment pad and o- ring to 
avoid getting debris on the o-ring seal. Discard the filter media and rinse the cartridge with clean 
water, removing and remaining DI resin. Refill the housing with resin, replace the pad and o-ring 
and replace the head cap. 

 

DI Cannister Filter: 

Undo the housing cap and remove the DI cartridge. Unscrew the filter from the 

bottom and discard the DI media. Rinse the housing and sediment pad with clean water removing 
any of the remaining expired DI. Fill the cannister with 1Kg of DI media (Try not to compress it, 
gently tap the cannister to allow the media to settle into position). Replace the sediment pas and 
screw the cap back on. 

III. Parts List 

Pre-filters: 

GT2-47-20KP  

20 Micron Washable Sediment Filter  

 

3 - 6 Months 

GT2-47-5K  

 

5 Micron Polyspun Sediment Filter   

 

6 Months 

GT4-10CTO   

5 Micron CTO Coconut Carbon Block 

 

6 - 12 Months 

RO Membranes: 

GT13-37-ALP  

Asprinn Reverse Osmosis Membrane 100GPD 

TDS Checking Required 

(4 pc Required) 

 

 

 

 

 

 

 

(1 – 3 Years) 

Post Filters: 

GT6-7C 

 

5 Micron inline GAC 2.5” 

 

 

 

5,000L / 6 Months 

GT6-22 

 

Inline DI Filter 2.5” 

 

 

 

 

Check TDS / 3 Months 

GT5-12S-350   

350g refill pack suit inline DI Filter 2.5” 

 

Check TDS / 3 Months 

GT4-14DI 

 

10” x 4.5” DI Cannister Filter Cartridge 

 

Check TDS / 6 – 12 Months 

GT5-12S 

 

Mixed Bed DI Resin   

 

 

 

Check TDS / 6 – 12 Months 

(1Kg per refill) 

Pumps/Solenoids/Switches: 

GT13-38LS 

 

8200L Reverse Osmosis Booster Pump 200GPD 

2,000Hr (12 Months Pro-rata) 

GT13-40 

 

Low Pressure Switch   

 

 

 

 

GT13-41 

 

High Pressure Switch 

GT13-39 

 

Brass Solenoid Valve 3/8” DC24v 

Housings: 

GT8-19G-Sump 

20” x 2.5” Blue Filter Housing Sump – No Cap 

GT8-31 

 

1812 Reverse Osmosis Membrane Housing 

GT8-11G 

 

10” x 4.5” DI Cannister Housing (Big Blue) 

Troubleshooting 

Problem 

Possible Cause(s) 

Solution 

Leaking 
between fitting 
and tubing 

Unseated tubing 

Check all tubing connections by firmly pushing them into the 
fitting. Check that there are no kinks or any obvious issues. If 
the problem persists, remove the tubing and check for a 
clean cut with no burs. Push the tubing back in and try again. 
If this does not work please contact customer support. 

Unit is not 
producing any 
water 

1. Water supply is off 
or disconnected. 
 
 

1. Turn it back on and ensure there are no obstructions in the 
fittings/tubing. 
 

Содержание GT1-12LS

Страница 1: ...ion Introduction 4 I Site Preparation 4 II Installation Mounting 4 III Installation Free Standing 4 IV Installing Connections Quick Connect 4 V Filter Protection 5 VI Drain Waste 5 VII Cartridge Insta...

Страница 2: ...ed below If these conditions are not met the system may not be suitable for the application and may not function as specified These systems are designed for filtration on mains water for the removal o...

Страница 3: ...s which may require treating before the system Bore Water filtration is used when the water meets specific conditions where an RO unit will be suitable to remove elevated salt levels in the water gene...

Страница 4: ...tem to reduce negative effects on the pressure flow and performance of the system It is also recommended that the process water filtered water does not have to travel more than 2m elevation above the...

Страница 5: ...ted Before Spun Spun Before Carbon Highest Micron Before Lowest Micron As an example a common filter set would be 5uM Polyspun 20uM Low Pressure Carbon 0 5uM Chloramine Reduction Carbon You would inst...

Страница 6: ...straight cut with no rough edges Measure a length of tubing from the drain valve located behind the pumps which is marked as to drain or Flow 2000 to a suitable drainage point Measure a length of tubi...

Страница 7: ...s the filters are classed as a consumable item III Automation The system is fitted with high and low pressure switches This will allow the system to know when to shut off due to the tank being full or...

Страница 8: ...arbon Block 6 12 Months RO Membranes GT13 37 ALP Asprinn Reverse Osmosis Membrane 100GPD TDS Checking Required 4 pc Required 1 3 Years Post Filters GT6 7C 5 Micron inline GAC 2 5 5 000L 6 Months GT6 2...

Страница 9: ...ing pH levels in lower EC water i e The guy at the pool shop is not going to cut it We have access to high quality testing equipment and frequently test our units and conduct research If you feel that...

Страница 10: ...pump may require replacing if it has been overworked outside the manufacturer s guidelines 2 Power surges may cause the power supply to short out Other things include water leaking or overheating An...

Страница 11: ...of of installation in the form of an invoice and or receipt Filter systems must be maintained as per FSA recommendations including the use of replacement filters fittings and components supplied by FS...

Страница 12: ...f the system is installed on an open circuit a plumber may not be required in this case the system must be installed in accordance with the user manual and determined to be correctly installed by FSA...

Отзывы: