FSA BB-PF30 Скачать руководство пользователя страница 2

 

 

 

EE106 BB-PF30 Bearing Alignment Gauge 

The gauge is used to check that the surface where 

the PF30 bearing cups press in are in alignment 
with each other. If the PF30 bearings are not able 

to be installed in alignment with each other, the 
bearings may bind and prematurely fail after 

crankset installation. 

 
 

 
 

 

 

 

 

 

Inspection   

1.

 

Check BB shell and remove any excess paint, 
metal chips, dirt or debris. 

2.

 

Insert shaft with handle into right or left BB shell 
opening. Slide the opposing side of the gauge 

onto the shaft moving each inspection surface 

into the right and left openings of the BB shell. 

3.

 

Gently press the gauge into the BB shell until it 

is completely inserted.   

The gauge will fit tightly into the BB shell. Do not 

use a hammer or any pounding motion to insert the 
gauge into the frame! 

 

 
 

 

 

 

If the BB shell is not in alignment it will be 
impossible to install the alignment gauge. 

Note: The tolerance of BB shell eccentric is 

±

0.02mm. 

 

 

 