background image

4-PORTS 10/100/1000M GIGABIT INDUSTRIAL PoE+ EXTENDER USER MANUAL

Note: 

1. If the connected device is not fully complying with IEEE 802.3af/at standard or in-line power device, the PoE-in-Use LED indicator

of the IPOEX4 will not be lit steadily.

2. According to IEEE 802.3af/at standard, the IPOEX4 will not inject power to the cable if not connecting to a standard IEEE 802.3af/at 

device.

3. 

DO NOT

 connect any PSE to port 1~ port 4 of the IPOEX4; it may damage the device permanently.

4. Power over Ethernet Budget

The following table lists how many PoE devices can be powered by the IPOE

X

4 under 1m distance:

Power Source

PoE Output Budget*

Max. Number of PDs supported

95W PoH PSE

75 watts max.

Class 4 PD@25 watts

3 units

Class 3 [email protected] watts

4 units

Class 2 PD@7 watts

4 units

90W 802.3bt PoE++ Type 4 

PSE

75 watts max.

Class 4 PD@25 watts

3 units

Class 3 [email protected] watts

4 units

Class 2 PD@7 watts

4 units

60W 802.3bt PoE++ Type 3 

PSE

50 watts max.

Class 4 PD@25 watts

2 units

Class 3 [email protected] watts

3 units

Class 2 PD@7 watts

4 units

30W 802.3at PoE+ PSE

25 watts max.

Class 3 [email protected] watts

1 units

Class 2 PD@7 watts

3 units

Remark: 

1. The PoE output budget means the aggregated power output of the 4 PSE ports. 

2. The aggregated power consumption will be below 60 watts if with PoE+ PSE.

3. Please check the power input LED for optimal power output. 

6

Содержание IPOEX4

Страница 1: ...Copyright 2009 2022 FS COM All Rights Reserved 4 PORTS 10 100 1000M GIGABIT INDUSTRIAL PoE EXTENDER USER MANUAL 4 Ports 10 100 1000M Gigabit Industrial PoE Extender User Manual...

Страница 2: ...l 1 2 2 LED Indicators 2 2 3 Grounding the Device 2 2 Hardware Introduction 1 3 Installation 3 4 Power over Ethernet Budget 6 5 Technical Specifications 7 6 Physical Dimensions 8 3 4 Connecting IPOEX4...

Страница 3: ...ms l Industrial PoE Extender x 1 l User s Manual x 1 l RJ45 Dust Cap x 5 l Wall Mounting Kit x 1 If any of these are missing or damaged please contact your dealer immediately if possible retain the ca...

Страница 4: ...power 40W Amber Blinks to indicate the system is providing 30W 40W PoE power Lights to indicate the system is providing 40W 50W PoE power 60W Amber Blinks to indicate the system is providing 50W 60W P...

Страница 5: ...ote This following pictures show how to install the device However the device in the picture is not the IPOEX4 3 1 DIN rail Mounting Installation 3 2 Wall mount Plate Mounting 3 3 Connecting IPOEX4 to...

Страница 6: ...e LED is not lit please check the remote PSE or the cable connecting to a PC or a network device to see if the cable is correct Or with an 802 3at device such as the target PD check whether the power...

Страница 7: ...lso the power injector which transmits DC voltage to the Cat5e 6 cable and transfers data and power simultaneously between the PSE and PD Step 3 Once the IPOEX4 detects the existence of an IEEE 802 3a...

Страница 8: ...ed by the IPOEX4 under 1m distance Power Source PoE Output Budget Max Number of PDs supported 95W PoH PSE 75 watts max Class 4 PD 25 watts 3 units Class 3 PD 12 9 watts 4 units Class 2 PD 7 watts 4 un...

Страница 9: ...rotection ESD Contact 6KV Air 8KV Surge 6KV Enclosure IP30 metal case Installation DIN rail kit and wall mount ear Dimensions W x D x H 32 x 87 8 x 135 mm Weignt 430g Power Consumption 5 6 watts 19 11...

Страница 10: ...u Fast Ethernet IEEE 802 3ab Gigabit Ethernet IEEE 802 3x Flow Control IEEE 802 3af Power over Ethernet IEEE 802 3at Power over Ethernet Plus IEEE 802 3bt Power over Ethernet Plus Plus IEEE 802 3az En...

Отзывы: