1.4 F3000 Vat Setup
Setup mode allows the controller to be set for language displays, vat sizes, and temperature range displays. Follow the steps
below to enter and navigate Vat Setup.
Vat Set Up
Left Display
Right Display
Action
OFF OFF
Press and hold
until Product Setup is displayed.
Product Setup
Press
to scroll to Vat setup and press
. Product setup is described on pages 1-11 through
1-14.
Vat setup
Enter code
Enter 3228.
System
Press
button or press
to scroll to Time/Date, Filter, E-Log, Change Password or Edit
Alarm Names. With desired choice displayed, press
. If SYSTEM is not chosen skip to the
relevant selection.
Language English
Press
to scroll to choice and press
.
2nd language
English
Press
to scroll to choice and press
.
(This option allows another language to be toggled
easily from the front panel (ex. Spanish as a second language.)).
Locale Non-ce
Press
to scroll to choice Non-CE or CE and press
.
ENERGY Gas
Press
to scroll to choice Gas or Electric and press
.
type KJ3
Full
Press
to scroll choices. Once the fryer type is chosen, press
.
System volume
9
Sets sound level for controller. Enter level, 1-9 (0=Lowest/ 9=Loudest). Press
.
Tempr format
F
Press
to scroll choices: F for Fahrenheit; C for Celsius. Press
.
Exit Melt Tempr
100F
Use numbered buttons to change default setting (use 10 for 0). Press
. (This is the
temperature for the fryer to exit the melt cycle.) Default is 100F (38C).
Setback tempr
250F
Use numbered buttons to change default setting (use 10 for 0). Press
. (This is the
temperature during setback or idle mode.) Default is 250F (121C).
Fresh oil
None
Press
to scroll choices JIB, Bulk-RTI, Bulk-F (Frontline) or None. Press
.
NOTE:. All
fryers should be set to NONE.
waste NONE
Press
to scroll choices JIB, Bulk-RTI, Bulk-F (Frontline) or None. Press
.
NOTE:. All
fryers should be set to NONE.
RECOVERY ALARM DISABLED
Press
to scroll choices DISABLED and ENABLED. (This is a recovery alarm that locks
out the fryer if the fryer does not heat properly. The default is disabled). Press
.
Exit Exit
Press
button.
OFF OFF
None required.
Time/date
Press
.
Time entry
time
Use numbered buttons to change time (use 10 for 0). Press
.
Date format
Mm/dd/yy
Press
to scroll choices. With the date format displayed, press
.
Enter date
date
Use numbered buttons to change date (use 10 for 0). Press
.
Exit Exit
Press
button once and press
to scroll to System, Time/Date, Filter, E-Log, Change
Password or Edit Alarm Names. With desired choice displayed, press
or press the Scan
button once to return the controller to OFF.
DST SETUP
This is daylight savings time setup. In the United States, daylight savings time begins each year at 2:00 A.M. on
the second Sunday in March, with clocks moving ahead one hour. Daylight savings time ends each year at 2:00
A.M. on the first Sunday in November, with clocks moving back one hour. For the two states and international
locations, which do not use DST, set to disabled.
OFF OFF
Press and hold
until Product Setup is displayed.
Product Setup
Blank
Press
to scroll to Vat setup and press
.
Vat setup
Enter code
Enter 3228.
DST
ENABLED
Press
to scroll choices DISABLED and ENABLED. Press
.
(This enables or disabled
daylight savings time. Default is enabled.) If disabled is chosen, pressing the
button,
displays exit. Press the exit scan
button three times to exit.
Continued on the following page