7  Main Components 

 

Item 

Part # 

Description 

106-4589 

Filter Pan Assembly 

 

200-8685 

Sana Grid Screen 

 

211-8703 

Stiffener, Pan Frame, Left 

 

212-8703 

Stiffener, Pan Frame, Right 

 

809-0417 

Nut, Flange, ¼"-20, Serrated 

 

810-1057 

Flex Line, 5/8" OD x 13" Long 

 

810-1668 

Adaptor, Male, 5/8" OD x ½" 

 

813-0062 

Elbow, ½", 90°, Black Metal 

 823-5022 

Hold 

Down 

Ring 

 823-5057 

Filter 

Pan 

106-4608 

Filter Pan Lid, Rear (larger) 

 

824-1459 

Lid, Filter Pan 

 

810-0180 

Handle, Filter Pan Lid 

 

809-0918 

Screw, 10-24 x ½" 

 

809-0191 

Washer, ¼" Spring Lock 

3 106-4610 

Rear 

Panel, 

Filter 

106-4613 

Cover Assembly, Top of Arm 

106-4647 

Plumbing, Oil Return 

106-8342 

Filter Pan Cover, Front 

7 200-8887 

Cover, 

Filter 

Plug 

210-8733 

Handle, Filter Unit 

9 210-8741 

Pump 

Housing 

10 

211-8723 

Bracket, Handle, LT 

11 

211-8825 

Clip, 5/8", Handle, LT 

12 

212-8723 

Bracket, Handle, RT 

13 

212-8825 

Clip, 5/8", Handle, RT 

14 

806-6034 

Pump/Motor 115V, 60 Hz 

15 

807-1041 

Switch, Toggle, 120V, 15A 

16 

807-1043 

Bushing, 1.06 ID Heyco 

17 

807-1219 

Receptacle, 120V, 3 wire 

18 

807-2469 

Bushing, 1" ID, Heyco 

19 

809-0059 

Nut, Grip ¼-20 x ¾ 

20 

809-0120 

Screw,10-32 x ½" Truss Head 

21 

809-0131 

Screw, Hex Head ¼"-20 x ¾  

22 

809-0189 

Washer, ¼" SAE Plain 

23 

809-0256 

Nut, Hex Keps 10-32 

24 

809-0412 

Screw, #10-1/2, Hex Head 

Содержание YPF95 Series

Страница 1: ...the Commercial Food Equipment Service Association recommends using CFESA Certified Technicians 24 Hour Service Hotline 1 800 551 8633 JUNE 2007 8196325 YPF95 Series Portable Filtration Systems Install...

Страница 2: ...plug for your protection against shock hazard and should be plugged directly into a properly grounded three hole receptacle Do not cut off remove or otherwise bypass the grounding prong on this plug I...

Страница 3: ...te operational cleaning and technical procedures and may not conform to on site management operational procedures NOTICE IF DURING THE WARRANTY PERIOD THE CUSTOMER USES A PART FOR THIS ENODIS EQUIPMEN...

Страница 4: ...Systems Installation Operation Manual TABLE OF CONTENTS Page 1 INTRODUCTION 1 1 2 IMPORTANT INFORMATION 2 1 3 INSTALLATION INSTRUCTIONS 3 1 4 FILTER OPERATION 4 1 5 CLEANING AND MAINTENANCE 5 1 6 TROU...

Страница 5: ...following information is required Model Number Type Serial Number Optional Features Item Part Number Quantity Needed 1 2 Service Information Call the 1 800 551 8633 or 318 865 1711 Service Hotline nu...

Страница 6: ...roughly Throughout this manual you will find notations enclosed in double bordered boxes similar to the ones below CAUTION CAUTION boxes contain information about actions or conditions that may cause...

Страница 7: ...through a representative Qualified personnel must be experienced in such work be familiar with all electrical precautions involved and have complied with all requirements of applicable national and l...

Страница 8: ...l as other manufacturers equipment Oil capacity is approximately 105 pounds Unit specifications are listed below Model Unit Height inches Unit Width inches Unit Length inches Tank Height inches Oil Ca...

Страница 9: ...oil filtration and draining cleaning procedures An ON OFF switch activates deactivates the filter pump and a 7 amp 120V or 5 amp 230V circuit breaker switches the power OFF if an overload occurs An i...

Страница 10: ...essories they will be needed for filter setup and operation Any accessories or starter kits included with the unit will be packaged inside the filter tank After unpacking immediately check the equipme...

Страница 11: ...1 Filter Pan Cover Front 2 Filter Pan Cover Rear 3 Hold Down Ring 4 Filter Paper one sheet 5 Screen Sana Grid 6 Filter Pan Assembly A First place the Sana Grid in the bottom of filter pan B Place one...

Страница 12: ...ter pan and will prevent splashing during filtration 4 1 2 3 4 1 Oil Baffle remove front lid 2 Filter Pan Cover Rear 3 Filter Pan 4 Drain Tube fryer to filter YPF95 portable filter positioned correctl...

Страница 13: ...e primarily as an independent filter unit Operations always start by ensuring the unit is properly plugged in and situated in the filter space between the fryers The general layout of a YPF95 Series p...

Страница 14: ...e crumb tray if equipped in portable filter systems must be emptied into a fireproof container at the end of frying operations each day Some food particles can spontaneously combust if left soaking in...

Страница 15: ...down ring in the filter pan on top of the filter paper 8 Measure 8 ounces of filter powder and distribute evenly over the surface of the paper 9 Replace the filter pan covers and slide it back into pl...

Страница 16: ...ottom of the frypot before closing the drain valve NOTE The oil return wand can also be mounted in the wand holster inside the pan for extended filtering periods polishing prior to refilling frypot NE...

Страница 17: ...unless cooking oil is at operating temperature 5 2 Each Filter Use Each time the portable filter is used Wash down the insides of the filter pan with hot oil during the filtering process DO NOT allow...

Страница 18: ...the filter unit and ensure that they are properly tightened DANGER The crumb tray if applicable in portable filter systems must be emptied into a fireproof container at the end of frying operations e...

Страница 19: ...bris The first indication of paper plugging is a slow oil flow return rate and a surging jerking in the filter unit To correct this review the instructions for the correct use of filter powder and cha...

Страница 20: ...ty pan Verify filter paper is clean and properly installed Refill pan and restart process Pump starts and abruptly stops Reset circuit breaker Pump is blocked or wiring is loose Call FASC for service...

Страница 21: ...witch Housing 120 230 VAC 50 60 Hz Motor w Thermal Overload Protector Electrical Junction Box C NC Thermal Overload Reset Switch T4 T5 T2 P1 P2 T3 T8 6 3 2 YPF95 230V Wiring BLK BRN GRN YEL BLU 5 Amp...

Страница 22: ...YPF95 SERIES PORTABLE FILTRATION SYSTEMS CHAPTER 7 PARTS LIST 7 1 7 Main Components...

Страница 23: ...809 0191 Washer Spring Lock 3 106 4610 Rear Panel Filter 4 106 4613 Cover Assembly Top of Arm 5 106 4647 Plumbing Oil Return 6 106 8342 Filter Pan Cover Front 7 200 8887 Cover Filter Plug 8 210 8733 H...

Страница 24: ...e Filter Pan 32 810 2957 Tubing Faucet Over the Top 33 813 0006 Bushing Hex to 3 8 NPT Black Metal 34 813 0022 Nipple x Close NPT Black Metal 35 813 0062 Elbow 1 2 90 Black Metal 36 813 0093 Nipple x...

Страница 25: ...THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 26: ...hreveport Louisiana 71135 1000 Shipping Address 8700 Line Avenue Shreveport Louisiana 71106 TEL 1 318 865 1711 FAX Parts 1 318 219 7140 FAX Tech Support 1 318 219 7135 PRINTED IN THE UNITED STATES SER...

Отзывы: