Frymaster SINBAD II Скачать руководство пользователя страница 2

 

 DANGER 

IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE, OR 

MAINTENANCE CAN CAUSE PROPERTY DAMAGE, INJURY, OR DEATH.  READ THE 

INSTALLATION, OPERATING, AND SERVICE INSTRUCTIONS THOROUGHLY BEFORE 

INSTALLING OR SERVICING THIS EQUIPMENT. 

 

 DANGER 

FOR YOUR SAFETY, DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE 

LIQUIDS OR VAPORS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. 

 

THIS EQUIPMENT IS TO BE INSTALLED IN COMPLIANCE WITH THE BASIC PLUMBING 

CODE OF THE BUILDING OFFICIALS AND CODE ADMINISTRATORS INTERNATIONAL, 

INC. (BOCA) AND THE FOOD SERVICE SANITATION MANUAL OF THE FOOD AND 

DRUG ADMINISTRATION. 

 

COMPUTERS 

FCC

 

This device complies with Part 15 of the FCC rules.  Operation is subject to the following two conditions:  

1) This device may not cause harmful interference, and 2) This device must accept any interference 

received, including interference that may cause undesired operation.  While this device is a verified Class 

A device, it has been shown to meet the Class B limits. 

 

CANADA 

This digital apparatus does not exceed the Class A or B limits for radio noise emissions as set out by the 

ICES-003 standard of the Canadian Department of Communications. 

 

Cet appareil numerique n’emet pas de bruits radioelectriques depassany les limites de classe A et B 

prescrites dans la norme NMB-003 edictee par le Ministre des Communcations du Canada.

 

Содержание SINBAD II

Страница 1: ...r a member of the Commercial Food Equipment Service Association recommends using CFESA Certified Technicians 819 5874 24 Hour Service Hotline 1 800 551 8633 MARCH 2005 SinBaD Installation and Operatio...

Страница 2: ...OOD AND DRUG ADMINISTRATION COMPUTERS FCC This device complies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2...

Страница 3: ...nstallation Operating and Service Personnel 1 2 1 5 Definitions 1 2 1 6 Shipping Damage Claim Procedure 1 3 CHAPTER 2 Installation and Operation 2 1 Installation 2 2 2 2 Self Zeroing 2 2 2 3 Operation...

Страница 4: ...SC or Distributor Service may also be ob tained by calling the Frymaster Service Department at 1 800 551 8633 When requesting service please have the following information ready Model Number Serial Nu...

Страница 5: ...ervice Personnel Operating information for Frymaster equipment has been prepared for use by qualified and or authorized personnel only as defined in Section 1 5 All installation and service on Frymast...

Страница 6: ...ives damaged 1 File a claim for damages immediately regardless of the extent of damages 2 Inspect for and record all visible loss or damage and ensure that this information is noted on the freight bil...

Страница 7: ...NIT Load Cell Arms behind front face of Dispense Chute Lid Sight Glass Crumb Pan and Basket Locator Rack Shown Removed from Unit ON OFF Switch Hopper Optional Basket Rack Accessory Kit Proximity Switc...

Страница 8: ...let of appropriate voltage refer to the data plate affixed to the upper right corner of the right side of the unit locking the casters and connecting the unit to an appropriate electrical source When...

Страница 9: ...at the sight glass is installed If it is not installed fries will fall out of the hopper during operation 8 Place the ON OFF Rocker Switch in the ON position The switch will illuminate indicating that...

Страница 10: ...til the new weight is attained If the batch weight is reduced the change will take effect with the next cycle after the dispensing chute is emptied If the dispensing chute does not fill within 30 seco...

Страница 11: ...with that switch The switch s indicator will light momentarily then go out showing that the weight for that switch has been successfully recorded 6 Repeat steps 4 and 5 for each of the remaining numbe...

Страница 12: ...s will disengage the hopper from its retainer allowing it to slide forward for removal Remove the dispensing chute by lifting it up from the load cell arms and carefully sliding it out toward you Thes...

Страница 13: ...id not correct the problem call FASC A The load cell may not have been satisfied within 30 seconds normally because the hopper is empty or the fries have bridged A Check the hopper to verify that the...

Страница 14: ...the drum will not turn or may turn erratically Verify that the dispense chute is properly positioned on the load cell arms C Batch weight of 2 25 lbs 1kg or greater has been programmed C The maximum w...

Страница 15: ...cutive times within 5 seconds after the PROGRAM Switch is pressed If more time is taken or if a selector other than 1 is pressed the unit automatically returns to the STANDBY mode UNIT GOES BACK TO ST...

Страница 16: ...THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 17: ...eport Louisiana 71135 1000 Shipping Address 8700 Line Avenue Shreveport Louisiana 71106 TEL 1 318 865 1711 FAX Parts 1 318 219 7140 Tech Support 1 318 219 7135 Price 4 00 PRINTED IN THE UNITED STATES...

Отзывы: