Frymaster PF50 Series Скачать руководство пользователя страница 10

 

PF50 SERIES PORTABLE FILTRATION SYSTEMS 

CHAPTER 2:  IMPORTANT INFORMATION 

 

 

2-3

 

2.3  Pre-Installation 

 

NOTE:  Failure to use qualified service personnel will void the Frymaster warranty. 
 

A.

 

Standards: Use of this filter unit must be in accordance with all applicable state and local 
codes. 

 

 DANGER 

This portable filter is equipped with a three-prong (grounding) plug for protection 

against electrical shock and must be plugged directly into a properly grounded, 
three-prong receptacle.  DO NOT CUT, REMOVE, OR OTHERWISE BYPASS THE 

GROUNDING PRONG ON THIS PLUG! 

 
 

B.

 

Electrical Connections: Domestic PF50 filter units require 115V 60 Hz., 15 amp electrical 
supply.  International/CE units require 230V 50 Hz., 7 amp electrical supply. Units are 
equipped with a grounded male receptacle for use with a 16-3 SJT power cord set.  If an 
extension cord is required, it must be a three-conductor, grounded power cord of at least 16 
gauge. 

 

 
2.4  Unpacking the Filter System 

 

Ensure the container is upright.  Unpack the filter carefully and remove all accessories from the 
carton.  Do not discard or misplace parts and/or accessories; they will be needed for filter setup 
and operation.  Any accessories or starter kits included with the unit will be packaged inside 
the filter tank. 

 

 

After unpacking, immediately check the equipment for visible signs of shipping damage.  If 
such damage has occurred, contact the carrier and file the appropriate freight claims.  Do not 
contact the factory, as the responsibility of shipping damage is between the carrier and dealer 
or end-user. 

 

If your equipment arrives damaged: 

 

a.

 

File claim for damages immediately – Regardless of extent of damage. 

 

b.

 

Visible loss or damage – Be sure this is noted on the freight bill or express receipt and is 
signed by the person making the delivery.  

 

c.

 

Concealed loss or damage – If damage is unnoticed until equipment is unpacked, notify 
freight company or carrier immediately, and file a concealed damage claim.  This should be 
done within 15 days of date of delivery.  Retain the shipping container for inspection. 

 
 

NOTE:  Frymaster does not assume responsibility for damage or loss incurred in transit.   

 
 

Содержание PF50 Series

Страница 1: ...Association recommends using CFESA Certified Technicians 24 Hour Service Hotline 1 800 551 8633 12 2017 PF50 Series Portable Filtration Systems Operating Manual Please read all sections of this manua...

Страница 2: ...ded cord of 16 gauge or greater WARNING This appliance is not intended for use by children under the age of 16 or persons with reduced physical sensory or mental capabilities or lack of experience and...

Страница 3: ...rational cleaning and technical procedures and may not conform to on site management operational procedures NOTICE IF DURING THE WARRANTY PERIOD THE CUSTOMER USES A PART FOR THIS FRYMASTER EQUIPMENT O...

Страница 4: ...Filtration Systems Operation Manual TABLE OF CONTENTS Page 1 INTRODUCTION 1 1 2 IMPORTANT INFORMATION 2 1 3 FILTER PREPARATION 3 1 4 OPERATING FILTER INSTRUCTIONS 4 1 5 CLEANING AND MAINTENANCE 5 1 6...

Страница 5: ...Needed 1 2 Service Information Call the 1 800 551 8633 or 318 865 1711 Service Hotline number for the location of your nearest Factory Authorized Service agent Always give the model and serial number...

Страница 6: ...ual thoroughly Throughout this manual you will find notations enclosed in double bordered boxes similar to the ones below CAUTION CAUTION boxes contain information about actions or conditions that may...

Страница 7: ...and are responsible for the installation of electrical appliances Qualified personnel must be experienced in such work be familiar with all electrical precautions involved and have complied with all...

Страница 8: ...rymaster fryers as well as other manufacturers equipment Oil capacity is approximately 50 pounds Unit specifications are listed below Model Unit Height inches Unit Width inches Unit Length inches Tank...

Страница 9: ...Return PF50S or a Suction Off Return PF50 switch activates deactivates the filter pump The filter also has a Heater Filter switch for use when filtering solid shortening A thermal overload switch on t...

Страница 10: ...is upright Unpack the filter carefully and remove all accessories from the carton Do not discard or misplace parts and or accessories they will be needed for filter setup and operation Any accessorie...

Страница 11: ...mp cloth or paper towel then with a dry cloth or paper towel WARNING Water detergent or boil out solution MUST NOT be allowed into the filter pan or filter system Irreversible pump damage will result...

Страница 12: ...sed dimples in the bottom of the pan 3 Place one sheet of filter paper on top of the support screen Ensure the paper evenly covers the filter pan bottom 4 Position the hold down ring on top of the fil...

Страница 13: ...export receptacle 3 If solid shortening is filtered through the portable filter turn the Heater Filter switch to HEATER see illustration below PF50 panel shown The white indicator light will illuminat...

Страница 14: ...low Oil will transfer from the frypot to the filter pan CAUTION DO NOT insert the tip of the hose nozzle into the sediment area of the frypot not applicable to S models Suction of sediment into the ho...

Страница 15: ...card the filter paper Clean the interior of the filter pan and all components Do not use detergent or water in the filter pan for cleaning 7 PF50S Return Only and PF50 Suction Return Filters a Gravity...

Страница 16: ...5 2 Each Filter Use Each time the PF50 portable filter is used Wash down the insides of the filter pan with hot oil during the filtering process DO NOT allow excessive residue buildup to occur inside...

Страница 17: ...er towel 5 Rinse all parts with clean water except filter pan interior and then dry all filter parts thoroughly before reassembling 6 Check the hose fitting on the pump and ensure that it is tight Che...

Страница 18: ...c When filtering is complete drain oil or shortening from the hose B Plugged Paper Improper use of the filter powder will cause a slow oil flow return rate The first indication of paper plugging is a...

Страница 19: ...r paper is clean and properly installed Refill pan and restart process Pump starts and abruptly stops Reset thermal overload switch Pump is blocked or wiring is loose Call FAS for service Motor failed...

Страница 20: ...ER HEATER LIGHT FILTER LIGHT HEATER FILTER SWITCH PUMP MOTOR CONTROL SWITCH 10P 5P 9P 6P 12P 13P 8P 11P 4P 1P 15P 2P 3P 14P WHITE BLK WHT FEMALE 7P 6 3 2 PF50 230V Wiring PUMP MOTOR CORDSET GREEN BLAC...

Страница 21: ...16P 4P 3P SWITCH FILTER LIGHT HEATER LIGHT FILTER CONTROL SWITCH PUMP MOTOR MOTOR PUMP GREEN WHITE BLACK CORDSET GREEN WHITE BLACK EXTERNAL CORD 115V OPTION 230V OPTION 6 3 4 PF50 PF50S 115 230V Pump...

Страница 22: ...Foshan Manitowoc Foodservice Col Ltd No 12 Chuang Ye North Road Song Gang Song Xia Industry Park Nanhai District Foshan Guangdong China 528234 SERVICE 1 318 865 1711 8197503 12 2017...