LOV
™
Generation II Technical Reference
26
Service Required Errors
A
SERVICE REQUIRED
SERVICE REQUIRED
error alternating with
YES
YES
displays on the computer. After
YES
YES
is
pressed the alarm is silenced. The computer displays an error message from the list below three
times with the location of the error. Then, the computer displays
SYSTEM ERROR FIXED?
SYSTEM ERROR FIXED?
YES/NO
YES/NO
. If
yes
yes
is chosen, enter code
1111
1111
. If
NO
NO
is chosen, the system returns to cook
mode for 15 minutes then redisplays error until issue is
fi
xed.
Pressing the MIB reset button during any fi lter function will generate a
SERVICE RE-
SERVICE RE-
QUIRED
QUIRED
error.
This is a list of the service required errors and cause.
ERROR MESSAGE
EXPLANATION
PUMP NOT FILLING
Oil not returning to vat quickly. Possible problems: dirty pad, bad
or missing O-rings, tripped or defective
fi
lter pump, actuators or
linkage.
DRAIN VALVE NOT OPEN
Drain valve failed to open; the valve’s position is unknown.
DRAIN VALVE NOT CLOSED
Drain valve failed to close; the valve’s position is unknown.
RETURN VALVE NOT OPEN
Return valve failed to open; the valve’s position is unknown.
RETURN VALVE NOT CLOSED
Return valve failed to close; the valve’s position is unknown.
MIB BOARD
Problem with CAN communications; check for loose CAN connec-
tions. MIB board failure.
AIF BOARD
MIB detects AIF missing; AIF board failure.
ATO BOARD
MIB detects ATO board connection lost; ATO board failure.
HIGH LIMIT FAILURE
High limit circuit has an issue.
AIF PROBE
AIF RTD reading out of range.
ATO PROBE
ATO RTD reading out of range.
TEMP PROBE FAILURE
TEMP Probe reading out of range.
MIB SOFTWARE
Internal MIB software error.
INVALID CODE LOCATION
SD card removed during update.
MISCONFIGURED ENERGY
TYPE
Energy type in fryer setup is incorrect; set proper energy type gas
or electric. Press 1234 to enter setup to properly con
fi
gure fryer.
RTC INVALID DATE
The date is invalid. Press 1234 to enter setup to properly con
fi
g-
ure fryer and set proper date.