1-10
Disconnect power to the filter system, remove the input plumbing from the pump, and use a
screwdriver to manually turn the gears.
●
Turning the pump gears in reverse will release a hard particle.
●
Turning the pump gears forward will push softer objects and solid shortening through the
pump and allow free movement of the gears.
Incorrectly sized or installed paper/pads will also allow food particles and sediment to pass through
and clog the suction tube on the bottom of the filter pan. Particles large enough to block the suction
tube may indicate that the crumb tray is not being used. Pan blockage can also occur if shortening is
left in the pan and allowed to solidify. Blockage removal can be accomplished by forcing the item
out with an auger or drain snake. Compressed air or other pressurized gases should not be used to
force out the blockage.
1.9.2 Replacing the Filter Motor, Filter Pump, and Related Components
1.
Drain the frypots into a Shortening Disposal Unit (SDU) or other appropriate metal container.
DANGER
DO NOT
drain more than one full frypot or two split frypots into the SDU at one time.
2.
Disconnect the fryer from the electrical power supply and reposition it to gain access to both the
front and rear.
3.
Disconnect the two flexlines running to the oil-return manifold at the rear of the fryer as well as
the pump suction flexline at the end of the filter pan connection (see photo below).
Disconnect flexlines indicated by the arrows.
4.
Remove the cover plate from the front of the motor and disconnect the motor wires.
5.
Unplug the pump motor assembly 6-pin connector C-2 and, using a pin pusher, disconnect the
vent vacuum-breaker solenoid (pins 2 and 5) that is attached to the oil return manifold.
Содержание FOOTPRINT RE80 Series
Страница 21: ...1 16 1 13 Wiring Diagrams 1 13 1 Basket Lift...
Страница 22: ...1 17 1 13 2 PBI Basket Lift...
Страница 23: ...1 18 1 13 3 Standard Component Wiring...
Страница 24: ...1 19 1 13 4 KFC1 and CM4S Component Wiring...
Страница 25: ...1 20 1 13 5 Component Wiring Single Phase 805 1786...
Страница 26: ...1 21 1 13 6 Component Wiring 480V Non Filter 805 1776...
Страница 27: ...1 22 1 13 7 Component Wiring Fast Ready...
Страница 28: ...1 23 1 13 8 Component Wiring KFC INDIA K3000...
Страница 29: ...1 24 1 13 9 Component Wiring KFC INDIA FAST...
Страница 30: ...1 25 1 13 10 Contactor Box Domestic 17 kW 1 13 11 Contactor Box Domestic 21 kW...
Страница 31: ...1 26 1 13 12 Contactor Box Export 17kW and 21kW...
Страница 32: ...1 27 1 13 13 Contactor Box Export Chinese Foshan 17kW and 21kW 1 13 14 Contactor Box Export KFC India 17kW...
Страница 47: ...2 15 2 5 Oil Return System Components 20 1 2 3 9 7 10 6 8 11 5 4 12 18 15 13 19 14 16...
Страница 57: ...2 25 2 9 Electronics and Wiring Components 2 9 1 Component Boxes...
Страница 59: ...2 27 2 9 2 Contactor Boxes...
Страница 67: ...THIS PAGE INTENTIONALLY LEFT BLANK...