1-15
1.11.1 ATO (Automatic Top-off) Troubleshooting
Problem Probable
Causes Corrective
Action
Frypots won’t top off.
A.
JIB out of oil
B.
Supply line from JIB is clogged.
C.
Probe temperature lower than setpoint.
D.
E.
Temperature in supply line or JIB is too
low.
F.
ATO board power loss
G.
Failed solenoid.
H.
ATO pump failed or over tightened.
I.
Failed transformer/harness.
J.
Failed ATO board.
K.
Top-off manifold solenoid failed closed.
L.
Jumper missing in ATO board 4 and 5
battery units
A.
Ensure the JIB is not out of oil and
supply line is in the JIB. Replace JIB
and press the
button when
prompted to reset top off system.
B.
Remove supply line from pump and
blow air through line towards JIB.
C.
Check to see that fryer is heating.
Fryer temperature must be at least
300°F (149°C). Check probe
resistance. If probe is bad, replace the
probe.
D.
E.
Ensure oil is above 70°F (21°C).
F.
Power to the ATO board has been cut
off. Restore power to the board and
switch all controllers off and on again
to readdress system.
G.
Check solenoid to see if functioning
properly.
H.
If the solenoid is working, ensure that
the screws on the bottom of the pump
are not too tight. Loosen the screws.
If loosening the screws doesn’t fix the
problem, replace the pump.
I.
Ensure transformer in ATO box is
functioning properly. Check power
from transformer to ATO board.
Ensure all harnesses are plugged
securely into place.
J.
Check for proper voltages using the
pin position chart found on page 1-17.
If ATO found defective, replace ATO
board.
K.
A pressure switch opens in the pump
with excessive pressure in the top-off
manifold, shutting down the pump.
Clear or replace solenoid.
L.
Jumper in J4/J5 missing on ATO #2
board in pins 7 & 8.
Controller
displays
TOPOFF OIL
EMPTY / CONFIRM
Top off system out of oil.
Fill top off system with oil and press the
(CONFIRM) button.
Frypot tops off cold.
Incorrect setpoint
Ensure setpoint is correct.
No power to ATO board
A.
J5 connection unplugged
B.
Fuse blown
C.
Transformer malfunction
A.
Check to ensure J5 on front of ATO
board is fully locked into connector.
B.
Ensure fuse below right control box is
not blown and fuse on the right side
of ATO box is not blown.
C.
Check that proper voltage is present
at transformer.
One vat doesn’t top off.
A.
Filter error exists.
B.
Pump, loose connection, RTD or ATO
issue.
A.
Clear filter error properly.
B.
Check ATO pump, wire connections,
RTD and ATO board.