background image

Page 

1

 of 

2

 

 

FilterQuick-T Software Update Instructions 

 

To update the software follow the attached instructions.  If you have any problems or 
questions call Frymaster at 1-800-551-8633.  

 

Loading Software from a USB drive 

 

Updating the software takes approximately 

30

 minutes for the entire fryer. Ensure the store has enough 

product cooked while updating the fryers.  

 

The software update may lose the location of product icon on the front screen after 
the update. Take either a picture/notation of the product locations on the 12 lanes 
for each vat to ensure they can be loaded back at the end of the update. 

 

 

Check with the manager about any LTO’s (Limited Time Offer) products that may 
have been programmed into the controllers.  If so capture the product details such 
as product name, cook time, etc. to program in later.

 

 

The following reset must be performed to clear items before 
updating.  

 

1.

 

Press the HOME button.

 

2.

 

Press the SERVICE button.

 

3.

 

Press the SERVICE button again. 

 

4.

 

Enter 3000. 

 

5.

 

Press the down arrow button.

 

6.

 

Press the FIB-RESET 2 button.

 

7.

 

Press YES to confirm.

 

8.

 

Press the check button.

 

9.

 

Press the home button.

 

 

The software only needs to be loaded in the USB port in the far left 
fryer cabinet and it will update 

all

 the controllers and boards in the 

system.  

To update the software, follow these steps carefully: 

 

1.

 

Switch all controllers to 

OFF

.  Press the information (?) button; press the down arrow; 

press the SW version button.  The controller displays INTIALIZING.  Write down the 
current (UIB, SIB, VIB and FIB) software versions. 

2.

 

On the 

far LEFT

 controller press the HOME button. 

3.

 

Press the SERVICE button. 

4.

 

Press the SERVICE button again. 

5.

 

Enter 3000 for and press the checkmark button. 

6.

 

Press the TECH MODES button. 

7.

 

Press the down arrow. 

8.

 

Press the SOFTWARE UPGRADE button.  

9.

 

Controller displays INSERT USB.    

10.

 

Open the far left cabinet door and slide the USB cover up (see Figure 1). 

11.

 

Insert the USB flash drive (see Figure 2). 

12.

 

The controller displays IS USB INSERTED? YES NO 

13.

 

Press the YES button after the USB flash drive is inserted. 

14.

 

Controller displays READING FILE FROM USB.  PLEASE DO NOT REMOVE USB 
WHILE READING. 

15.

 

Controller displays READING COMPLETED, PLEASE REMOVE USB. 

16.

 

Remove the USB flash drive and lower cover over the USB slot. 

17.

 

Press the YES button after the USB flash drive is removed. 

18.

 

Controller displays CONFIRM CONTROLLERS AVAILABLE FOR UPGRADE FIB 
AND UIB. 

19.

 

Press the YES button to continue or NO to exit. 

20.

 

Controller displays UIB/FIB – DATA TRANSFER IN PROGRESS, WILL COMPLETE 
IN X MINUTES for each board. 

 

Figure 1 

 

Figure 3 

 

Figure 2 

8197467   07/2017  rev.07.07.2017 