![Frymaster FilterQuick easyTouch FQE30U Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/frymaster/filterquick-easytouch-fqe30u/filterquick-easytouch-fqe30u_installation-operation-and-maintenance-manual_2340456037.webp)
5-9
Code
ERROR MESSAGE
EXPLANATION
E36 VALVE INTERFACE BOARD FAILURE -
FILTRATION AND TOP OFF DISABLED - CALL
SERVICE
Valve Interface Board connections lost or
board failure.
E37 AUTOMATIC INTERMITTENT FILTRATION
PROBE FAILURE - FILTRATION DISABLED - CALL
SERVICE
AIF RTD reading out of range.
E39 CHANGE FILTER PAD
25-hour timer has expired or dirty filter
logic has activated.
E41
OIL IN PAN ERROR
The system detects that oil may be present
in the filter pan.
E42
CLOGGED DRAIN (Gas)
Vat did not empty during filtration
E43
OIL SENSOR FAILURE - CALL SERVICE
Oil level sensor may have failed.
E44 RECOVERY
FAULT
Recovery time exceeded maximum time
limit.
E45
RECOVERY FAULT – CALL SERVICE
Recovery time exceeded maximum time
limit for two or more cycles.
E46 SYSTEM INTERFACE BOARD 1 MISSING - CALL
SERVICE
SIB board 1 connection lost or board
failure.
E51
DUPLICATE BOARD ID - CALL SERVICE
Two or more controllers have the same
location ID.
E52 USER INTERFACE CONTROLLER ERROR - CALL
SERVICE
The controller has an unknown error.
E53
CAN BUS ERROR - CALL SERVICE
Communications are lost between boards.
E54
USB ERROR
USB connection lost during an update.
E55 SYSTEM INTERFACE BOARD 2 MISSING - CALL
SERVICE
SIB board 2 connection lost or board
failure.
E61 MISCONFIGURED ENERGY TYPE
The fryer is configured for the incorrect
energy type.
E62
VAT NOT HEATING – CHECK ENERGY SOURCE –
XXXF OR XXXC
The vat is not heating properly.
E63
RATE OF RISE
Rate of rise error occurred during a
recovery test.
E64 FILTRATION INTERFACE BOARD FAILURE -
FILTRATION AND TOP OFF DISABLED - CALL
SERVICE
Filtration Interface Board connections lost
or board failure.
E65 CLEAN OIB SENSOR – XXX F OR XXX C - CALL
SERVICE
Gas -The oil is back sensor does not detect
oil. Clean oil sensor.
E66
DRAIN VALVE OPEN – XXXF OR XXXC
Drain valve is opened during cooking.
E67
SYSTEM INTERFACE BOARD NOT CONFIGURED
- CALL SERVICE
Controller is turned on when the SIB board
is not configured.
E68
OIB FUSE TRIPPED – CALL SERVICE
The VIB board OIB fuse has tripped and
didn’t reset.
E69
RECIPES NOT AVAILABLE – CALL SERVICE
The controller has not been programmed
with product recipes. Replace controller