HIGH EFFICIENCY DECATHLON (HD) SERIES GAS FRYERS
CHAPTER 5: CONTROLLER OPERATING INSTRUCTIONS
5–2
5.1 Operating Instructions: Electronic Thermostat Controller (cont.)
FRYER POWER SWITCH
– This switch turns the fryer on and off. When the power switch is in
the "ON" position, the indicator light will be lit when calling for heat.
BOIL-OUT SWITCH
(Optional)
– When the boil-out switch is "ON", it will bypass the electronic
thermostat melt-cycle, and allow the water temperature to reach approximately 196°F (91°C).
DRAIN RESET SWITCH
(Optional)
– Resets drain safety switch after draining the fryer. Drain
valve must be closed completely before resetting switch.
MANUAL FILTER POWER SWITCH
(
if equipped with filter system
)
– Controls power to the
filter pump in the event the primary system fails.
Fryer Power Switch should be in
"
OFF
"
position
when in use.
FILTER RESET BREAKER
(7 Amp Circuit Breaker- 120VAC or 5 Amp Circuit Breaker-
230VAC) – the breaker is inline between the filter switch and the pump. Ensure filter power is off
prior to resetting or replacing.
5 AMP (115VAC) or 2 AMP (230VAC) FUSE
– each fryer circuit is protected by a 5 amp
(115VAC) or 2 amp (230VAC) fuse located under the control panel.
5.2 Electronic Thermostat Controller/Computer
POWER
BOIL OUT
F
F
N
F
BOIL OUT
F
O
F
O
N
F
F
O
F
POWER
O
O
O
M
K
N
O
N
MAIN POWER
U
P
T
O
ON OFF ON
A
C
B
T
Fryer Power Switch: controls power to
each individual fryer, both in Electronic
Thermostat or back-up mode.
Boil-Out Switch: operates only in "Electronic Thermostat" mode.
When "ON", this switch bypasses the Electronic Thermostat
melt-cycle and allows the water temperature to reach 196°F
(91°C).
Main Power Switch (optional): connects/disconnects primary
power; double-lighted with center position "OFF". This switch
controls two Electronic Thermostat controllers/Compu-Fry or
remote computers and/or two back-up thermostats (optional).
High-Limit Reset Switch: located under
each individual control panel. This
switch must be manually reset if fryer
exceeds high-limit setpoint.
Filter Reset Switch [7 Amp (115VAC) or
5 Amp (230VAC) Circuit Breaker]: this
switch is inline between the filter pump
and incoming line voltage. Ensure
power is "OFF" before resetting or
replacing.