background image

 

YSCFHC18G HIGH EFFICIENCY COOL ZONE SERIES GAS FRYERS 

CHAPTER 1:  INTRODUCTION 

 

 

1-2 

1.3  Service Information 

 
Call the Frymaster Service Hotline, 1-800-551-8633, for the location of your nearest factory 
authorized service center (ASA). To assist you more efficiently, always provide the service 
technician with the model number, gas type, serial number, and the nature of the problem. 

 

 

1.4  Computer Information

 

 

This equipment has been tested and found to comply with the limits for a Class A digital device, 
pursuant to Part 15 of the FCC rules. While this device is a verified Class A device, it has been 
shown to meet the Class B limits. These limits are designed to provide reasonable protection against 
harmful interference when the equipment is operated in a commercial environment. This equipment 
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance 
with the instruction manual, may cause harmful interference to radio communications. Operation of 
the equipment in a residential area is likely to cause harmful interference in which case the user will 
be required to correct the interference at his own expense. 
 
The user is cautioned that any changes or modifications not expressly approved by the party 
responsible for compliance could void the user's authority to operate the equipment. 
 
If necessary, the user should consult the dealer or an experienced radio and television technician for 
additional suggestions. 
 
The user may find the following booklet prepared by the Federal Communications Commission 
helpful:  "How to Identify and Resolve Radio-TV Interference Problems".  This booklet is available 
from the U.S. Government Printing Office, Washington, DC 20402, Stock No. 004-000-00345-4. 

 
 
1.5  Safety Information 

 

Before attempting to operate your unit, read the instructions in this manual thoroughly. 
 
Throughout this manual, you will find notations enclosed in double-bordered boxes similar to the 
ones below. 

 

 CAUTION 

CAUTION 

boxes contain information about actions or conditions that 

may cause or result in a 

malfunction of your system

 

 

 WARNING 

WARNING 

boxes contain information about actions or conditions that 

may cause or result in 

damage to your system

, and which may cause your system to malfunction. 

 

Содержание COOL ZONE SERIES *8196329*

Страница 1: ...rcial Food Equipment Service Association recommends using CFESA Certified Technicians 24 Hour Service Hotline 1 800 551 8633 Price 10 00 OCT 2008 8196329 YSCFHC18G High Efficiency Cool Zone Series Gas...

Страница 2: ...s installed NOTICE Drawings and photos used in this manual are intended to illustrate operational cleaning and technical procedures and may not conform to onsite management operational procedures NOTI...

Страница 3: ...detects a gas leak must be posted in a prominent location This information can be obtained from the local gas company or gas supplier DANGER The crumb tray in fryers equipped with a filter system must...

Страница 4: ...ers INSTALLATION OPERATION MANUAL TABLE OF CONTENTS Page 1 INTRODUCTION 1 1 2 IMPORTANT INFORMATION 2 1 3 INSTALLATION INSTRUCTIONS 3 1 4 DAILY OPERATION 4 1 5 FILTRATION 5 1 6 PREVENTATIVE MAINTENANC...

Страница 5: ...horized Service Technician ASA Address Telephone Fax Model Number Serial Number Gas Type 1 2 Ordering Parts Customers may order parts directly from their local authorized service agency ASA If the tel...

Страница 6: ...ea is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense The user is cautioned that any changes or modifications not expressly...

Страница 7: ...ed Installation Personnel Qualified authorized personnel are those who have carefully read the information in this manual and have familiarized themselves with the equipment functions or who have had...

Страница 8: ...ier immediately and file a concealed damage claim This should be done within fifteen 15 days of date of delivery Be sure to retain container for inspection NOTE Frymaster Does Not Assume Responsibilit...

Страница 9: ...GER This appliance is equipped with a three prong grounding plug for your protection against electrical shock and must be plugged directly into a properly grounded three prong receptacle Do not cut re...

Страница 10: ...upplied 6 inch 15 cm adjustable legs or 5 inch 13 cm casters C Installation Standards 1 U S installations must meet 2 Canadian installations must meet American National Standard Institute CAN 1 B149 I...

Страница 11: ...mproper fryer operation 4 Do not place the fryer s flue outlet directly into the plenum of the hood as it will affect the gas combustion of the fryer 5 Never use the interior of the fryer cabinet for...

Страница 12: ...loor where the fryers are installed must be level 2 With the fryer level in its final position install the restraints provided with the unit to limit its movement so that it does not depend on or tran...

Страница 13: ...removed from the fryer before attempting to move it to avoid oil spills falls and severe burns This fryer may tip and cause personal injury if not secured in a stationary position DANGER Do not attach...

Страница 14: ...llation If installed with legs do not push against any unit edges to adjust its position Use a pallet or lift jack to lift it slightly and place it where it is to be installed B Relocating the Fryer I...

Страница 15: ...ched to the topside of the base mounting plates at the factory to capture hex head screws as they are screwed in 5 Tighten the bolts to 50 in lbf 5 65 joules minimum torque 6 After legs and rear rigid...

Страница 16: ...If the floor is uneven or has a decided slope place the fryer on a smooth platform C If the fryer is moved re level the fryer following the instructions given in Steps 3 3 A C D Installing Optional S...

Страница 17: ...rvice line must be the same size or greater than the fryer inlet line YSCFH18G gas fryers are equipped with a inch 22 mm male inlet The gas supply line must be sized to accommodate all gas fired equip...

Страница 18: ...ompound that is not affected by the chemical action of LP gases DO NOT apply thread compound to the first two pipe threads doing so will cause clogging of the burner orifices and control valve Manual...

Страница 19: ...the regulator is out of adjustment or serious pressure fluctuations are observed C Only qualified service personnel should make adjustments to the regulators D Orifices The fryer can be ordered to op...

Страница 20: ...straints 4 If it is necessary to disconnect the restraint it must be reconnected after the fryer has been returned to its originally installed position WARNING Do not attach accessories to this fryer...

Страница 21: ...appliance from one type of gas to another should only be performed by qualified licensed and authorized installation or service personnel as defined in Section 1 6 of this manual See below for gas va...

Страница 22: ...e ANSI NFPA 70 or the Canadian Electrical Code CSA C22 2 Do not cut or remove the ground prong from the power cord plug Do not attempt to use this appliance in a power outage 3 8 Safety Switches A Fry...

Страница 23: ...ty switch it deactivates the gas valve preventing burner ignition until the oil level extends above the heating tubes 3 High limit Reset Located in each fryer cabinet under the control panel This swit...

Страница 24: ...l return handles in the center of the cabinet return oil through the over the top system Ensure the faucet is positioned over the emptied vat before running oil through the over the top return system...

Страница 25: ...injure the operator 3 10 Final Preparation 1 The YSCFH18G frypot shortening capacity is approximately 40 5 kg 90 lb 2 Ensure fryer power switches are OFF 3 Cooking Oil Fill the fryer to the bottom OI...

Страница 26: ...computer will display drop NOTE For FAST equipped fryers see the Fast manual for operation instructions 7 After shortening reaches the setpoint temperature let the burners cycle at least four times th...

Страница 27: ...wall If solid shortening is used melt the shortening following procedures in Section 3 10 Final Preparation A Pilot lighting procedure Electronic Ignition a Turn gas ON b Turn electric power ON with...

Страница 28: ...2 KFC 1 Cooking Computer Turn the computer ON and ensure at least one LED is lit above a product button 1 9 Select a cooking program as described in the KFC 1 SMS Cooking Computer User Guide NOTE For...

Страница 29: ...once daily or more frequently if cooking is heavy This assures the longest life possible for the shortening a better taste to the food being prepared and minimizes flavors being transferred from batch...

Страница 30: ...etable oil If using solid shortening always ensure the return lines are clear before turning off the filter pump Hang any flexible lines up to drain Solid shortening will solidify as it cools and clog...

Страница 31: ...ar gloves Pull the filter pan out of the filter cabinet Remove cover 2 Remove crumb screen If crumbs are present in the crumb screen empty the screen into a fireproof container Thoroughly wash the scr...

Страница 32: ...ean the pan and all pan components as described for the crumb screen Step 2 7 Inspect the pickup tube and ensure vent hole is open and free of shortening debris 8 Replace filter screen and drape one s...

Страница 33: ...een is cleaned throughout the workday 12 Return pan cover to the filter pan 13 Return filter pan to fryer cabinet ensuring that the two drainpipe extensions are directly over the opening in the filter...

Страница 34: ...oil to cool to 100 F 38 C before draining into a metal container stockpot or disposal unit DANGER Do not drain more than one frypot at a time into the built in filtration unit to avoid overflow and s...

Страница 35: ...Stir the oil with the L shaped Teflon brush to suspend debris prior to draining 3 Open the fryer drain valve by pushing the red handle under the frypot to be filtered to the right until it is complete...

Страница 36: ...hing one of the oil return valves to the left Oil return handles on the far sides of the cabinet return oil to the frypot through rear ports which flush debris from the bottom of the frypot The two re...

Страница 37: ...15 30 seconds to ensure the oil return lines are clear of oil Over the top Oil Return Allow the faucet to sputter for 15 30 seconds to ensure the oil return lines are clear of oil 8 Turn off the filte...

Страница 38: ...screen and empty debris into a fireproof container If possible wash all filter pan components in hot soapy water Rinse and dry thoroughly Section 5 2 Step 7 If not the filter pan should be thoroughly...

Страница 39: ...commercial grade cleaner formulated to effectively clean and sanitize food contact surfaces Read the directions for use and precautionary statements before use Particular attention must be paid to th...

Страница 40: ...are present and properly installed Verify that component box components e g computer controller transformers relays interface boards are in good condition and free of oil build up and other debris In...

Страница 41: ...e filter pan and close the frypot drain valve Place the oil return handle in the OPEN position Allow all oil to return to the frypot The frypot should refill in no more than 2 minutes and 30 seconds M...

Страница 42: ...taking steps to ensure that it doesn t happen again If a controller malfunctions because of a poor connection check all other connections too If a fuse continues to blow find out why Always keep in mi...

Страница 43: ...still fails to turn ON when the ON OFF button is pressed contact an authorized service agent 7 2 2 Computer is ON but the gas valves fail to energize 1 Ensure float switch is not stuck in down positi...

Страница 44: ...esired setpoint 3 Place a thermometer near the temperature sensing probe within 1 inch of the temperature probe and approximately 3 in 75 mm deep into the shortening see illustration Page 7 3 4 Press...

Страница 45: ...tration If the probe adjustment is correct the computer probe circuit may be faulty If probe adjustment is incorrect it will require adjustment 6 Contact your authorized service agent if any of the fo...

Страница 46: ...when ready to cook 6 If the KFC 1 SMS computer message DRAIN OPEN remains after Steps 1 4 contact an authorized service agent Possible malfunctions are a Drain microswitch may be faulty b Drain circui...

Страница 47: ...small and appear lazy shortening does not come up to temperature quickly Contact an authorized service technician for service C Fryer will not reach setpoint temperature and or runs erratically 1 Inc...

Страница 48: ...per and screen are clean and properly installed Refill pan and restart process Pump starts and abruptly stops Reset thermal overload Verify wiring harness is properly connected a damaged harness shoul...

Страница 49: ...YSCFHC18G HIGH EFFICIENCY COOL ZONE SERIES GAS FRYERS CHAPTER 7 TROUBLESHOOTING 7 8 7 4 Wiring Diagrams...

Страница 50: ...YSCFHC18G HIGH EFFICIENCY COOL ZONE SERIES GAS FRYERS CHAPTER 7 TROUBLESHOOTING 7 9 Fast Equipped Control and Filter Circuit...

Страница 51: ...YSCFHC18G HIGH EFFICIENCY COOL ZONE SERIES GAS FRYERS CHAPTER 7 TROUBLESHOOTING 7 10 KFC 1 Equipped Control and Filter Circuit...

Страница 52: ...L C 8700 Line Avenue Shreveport Louisiana 71106 TEL 1 318 865 1711 FAX Parts 1 318 688 2200 FAX Call Center 1 318 219 7135 Price 10 00 PRINTED IN THE UNITED STATES SERVICE HOTLINE 1 800 551 8633 OCT 2...

Отзывы: