24G SERIES FLATBOTTOM GAS FRYERS
CHAPTER 1: SERVICE PROCEDURES
1-4
MELT CYCLE DISABLE
6
5
1
AC1
3
AC
2
3A
2A
7
8
9
1A
EX
T P
O
T
PROBE
10
11
2
COM
REL
A
Y
NO
12
13
NC
14
Not used
Line voltage enters the interface board at terminals 1 and 3. The temperature controls
(potentiometer) are connected to terminals 7, 8 and 9. The sensor probe circuit is connected to
terminals 10 and 11. The high-limit and gas valve routes through terminal 12. Terminals 2 and 13
are jumped out. Terminals 5 and 6 are the melt-cycle disable circuit. The melt cycle is enabled
unless terminals 5 and 6 are jumped out.
Thermatron Controller Board